summaryrefslogtreecommitdiff
AgeCommit message (Collapse)Author
2014-12-08Merge branches 'powercap', 'pm-clk', 'pm-config' and 'pm-opp'Rafael J. Wysocki
* powercap: powercap / RAPL: fix build dependency on iosf_mbi powercap / RAPL: add new model ids powercap / RAPL: handle atom and core differences powercap / RAPL: abstract per cpu type functions * pm-clk: PM / clock_ops: make __pm_clk_enable more generic PM / clock_ops: Add pm_clk_add_clk() * pm-config: PM: Kconfig: fix unmet dependency for CPU_PM * pm-opp: PM / OPP replace kfree_rcu() with call_srcu() in opp_set_availability() PM / OPP Introduce APIs to remove OPPs PM / OPP mark OPPs as 'static' or 'dynamic' PM / OPP don't match for existing OPPs when list is empty PM / OPP rename 'head' as 'rcu_head' or 'srcu_head' based on its type
2014-12-08f2fs: use atomic for counting inode with inline_{dir,inode} flagChao Yu
As inline_{dir,inode} stat is increased/decreased concurrently by multi threads, so the value is not so accurate, let's use atomic type for counting accurately. Signed-off-by: Chao Yu <chao2.yu@samsung.com> Signed-off-by: Jaegeuk Kim <jaegeuk@kernel.org>
2014-12-08Merge branches 'acpi-video' and 'acpi-pmic'Rafael J. Wysocki
* acpi-video: ACPI / video: Run _BCL before deciding registering backlight * acpi-pmic: ACPI / PMIC: AXP288: support virtual GPIO in ACPI table ACPI / PMIC: support PMIC operation region for XPower AXP288 ACPI / PMIC: support PMIC operation region for CrystalCove iio/axp288_adc: remove THIS_MODULE owner mfd/axp20x: avoid irq numbering collision iio: adc: Add module device table for autoloading iio: adc: Add support for axp288 adc mfd: axp20x: Extend axp20x to support axp288 pmic
2014-12-08Merge back earlier ACPI backlight material for 3.19-rc1.Rafael J. Wysocki
2014-12-08Merge branches 'acpi-scan', 'acpi-pm', 'acpi-lpss' and 'acpi-processor'Rafael J. Wysocki
* acpi-scan: ACPI: Add _DEP support to fix battery issue on Asus T100TA * acpi-pm: ACPI / sleep: Drain outstanding events after disabling multiple GPEs ACPI / PM: Fixed a typo in a comment * acpi-lpss: dmaengine: dw: enable runtime PM ACPI / LPSS: introduce a 'proxy' device to power on LPSS for DMA ACPI / LPSS: allow to use specific PM domain during ->probe() ACPI / LPSS: add all LPSS devices to the specific power domain * acpi-processor: ACPI / cpuidle: avoid assigning signed errno to acpi_status ACPI / processor: remove unused variabled from acpi_processor_power structure ACPI / processor: Update the comments in processor.h
2014-12-08Merge branch 'acpica'Rafael J. Wysocki
* acpica: ACPICA: Events: Always modify GPE registers under the GPE lock ACPICA: Save current masks of enabled GPEs after enable register writes ACPICA: Update version to 20141107. ACPICA: Disassembler: Emit correct string for 0 stop bits. ACPICA: Disassembler: Update for C-style expressions. ACPICA: Disassembler: Add support for C-style operators and expressions. ACPICA: acpiexec: Add option to specify an object initialization file. ACPICA: iASL: Add support for to_PLD macro.
2014-12-08Merge branches 'acpi-config', 'acpi-osl', 'acpi-utils' and 'acpi-tables'Rafael J. Wysocki
* acpi-config: ACPI / Kconfig: Remove redundant depends on ACPI * acpi-osl: ACPI / OSL: Add IRQ handler flushing support in the OSL. ACPI / osl: speedup grace period in acpi_os_map_cleanup * acpi-utils: ACPI: remove unnecessary sizeof(u8) * acpi-tables: ACPI / table: Always count matched and successfully parsed entries ACPI / table: Add new function to get table entries
2014-12-08Merge branch 'device-properties'Rafael J. Wysocki
* device-properties: leds: leds-gpio: Fix multiple instances registration without 'label' property leds: leds-gpio: Fix legacy GPIO number case ACPI / property: Drop size_prop from acpi_dev_get_property_reference() leds: leds-gpio: Convert gpio_blink_set() to use GPIO descriptors ACPI / GPIO: Document ACPI GPIO mappings API net: rfkill: gpio: Add default GPIO driver mappings for ACPI ACPI / GPIO: Driver GPIO mappings for ACPI GPIOs input: gpio_keys_polled: Make use of device property API leds: leds-gpio: Make use of device property API gpio: Support for unified device properties interface Driver core: Unified interface for firmware node properties input: gpio_keys_polled: Add support for GPIO descriptors leds: leds-gpio: Add support for GPIO descriptors gpio: sch: Consolidate core and resume banks gpio / ACPI: Add support for _DSD device properties misc: at25: Make use of device property API ACPI: Allow drivers to match using Device Tree compatible property Driver core: Unified device properties interface for platform firmware ACPI: Add support for device specific properties
2014-12-08f2fs: cleanup path to need cp at fsyncChangman Lee
Added some commentaries for code readability and cleaned up if-statement clearly. Signed-off-by: Changman Lee <cm224.lee@samsung.com> Signed-off-by: Jaegeuk Kim <jaegeuk@kernel.org>
2014-12-08f2fs: check if inode state is dirty at fsyncChangman Lee
If inode state is dirty, go straight to write. Suggested-by: Jaegeuk Kim <jaegeuk@kernel.org> Signed-off-by: Changman Lee <cm224.lee@samsung.com> Signed-off-by: Jaegeuk Kim <jaegeuk@kernel.org>
2014-12-08f2fs: count the number of inmemory pagesJaegeuk Kim
This patch adds counting # of inmemory pages in the page cache. Signed-off-by: Jaegeuk Kim <jaegeuk@kernel.org>
2014-12-08f2fs: release inmemory pages when the file was closedJaegeuk Kim
If file is closed, let's drop inmemory pages. Signed-off-by: Jaegeuk Kim <jaegeuk@kernel.org>
2014-12-08f2fs: set page private for inmemory pages for truncationJaegeuk Kim
The inmemory pages should be handled by invalidate_page since it needs to be released int the truncation path. Signed-off-by: Jaegeuk Kim <jaegeuk@kernel.org>
2014-12-08f2fs: count inline_xx in do_read_inodeJaegeuk Kim
In do_read_inode, if we failed __recover_inline_status, the inode has inline flag without increasing its count. Later, f2fs_evict_inode will decrease the count, which causes -1. Signed-off-by: Jaegeuk Kim <jaegeuk@kernel.org>
2014-12-08f2fs: do retry operations with cond_reschedJaegeuk Kim
This patch revists retrial paths in f2fs. The basic idea is to use cond_resched instead of retrying from the very early stage. Suggested-by: Gu Zheng <guz.fnst@cn.fujitsu.com> Reviewed-by: Chao Yu <chao2.yu@samsung.com> Signed-off-by: Jaegeuk Kim <jaegeuk@kernel.org>
2014-12-08thermal: cpu_cooling: update copyright tagsViresh Kumar
Adding my copyright information for two purposes: - To get cc'd for future patches to review (Only if people read this header while sending mail) - Have done enough changes to earn a place here? Cc: Amit Daniel Kachhap <amit.daniel@samsung.com> Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org> Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08thermal: cpu_cooling: Use cpufreq_dev->freq_table for finding level/freqViresh Kumar
get_property() was an over complicated beast with BUGs. It used to believe that cpufreq table is present in ascending or descending order, which might not always be true. Previous patch has created another freq table in descending order for us and we better use it now. With that get_property() simply goes away and another helper get_level() comes in. Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org> Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08thermal: cpu_cooling: Store frequencies in descending orderViresh Kumar
CPUFreq framework *doesn't* guarantee that frequencies present in cpufreq table will be in ascending or descending order. But cpu_cooling somehow assumes that. Probably because most of current users are creating this list from DT, which is done with the help of OPP layer. And OPP layer creates the list in ascending order of frequencies. But cpu_cooling can be used for other platforms too, which don't have frequencies arranged in any order. This patch tries to fix this issue by creating another list of valid frequencies in descending order. Care is also taken to throw warnings for duplicate entries. Later patches would use it to simplify code. Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org> Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08thermal: cpu_cooling: Pass 'cpufreq_dev' to get_property()Viresh Kumar
We already know the value of 'cpufreq_dev->max_level' and so there is no need calculating that once again. For this, we need to send 'cpufreq_dev' to get_property(). Make all necessary changes for this change. Because cpufreq_cooling_get_level() doesn't have access to 'cpufreq_dev', it is updated to iterate over the list of cpufreq_cooling_devices to get cooling device for the cpu number passed to it. This also makes it robust to return levels only for the CPU registered via a cooling device. We don't have to support anything that isn't registered yet. Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org> Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08thermal: cpu_cooling: use cpufreq_dev_list instead of cpufreq_dev_countViresh Kumar
As we already have a list of cpufreq_cooling_devices now, lets use it instead of a local counter. Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org> Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08thermal: cpu_cooling: get_property() doesn't need to support GET_MAXL anymoreViresh Kumar
We don't use get_property() to find max levels anymore as it is done at boot now. So, don't support GET_MAXL in get_property(). Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org> Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08thermal: cpu_cooling: find max level during device registrationViresh Kumar
CPU frequency tables don't update after the driver is registered and so we don't need to iterate over them to find total number of states every time cpufreq_get_max_state() is called. Do it once at boot time. Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org> Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08thermal: cpu_cooling: remove unnecessary wrapper get_cpu_frequency()Viresh Kumar
get_cpu_frequency() isn't doing much by itself, just calling get_property(). And so this wrapper isn't required at all. Get rid of it. Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org> Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08thermal: cpu_cooling: Merge cpufreq_apply_cooling() into cpufreq_set_cur_state()Viresh Kumar
cpufreq_apply_cooling() has a single caller, cpufreq_set_cur_state() and cpufreq_set_cur_state() is an unnecessary wrapper over cpufreq_apply_cooling(). Get rid of it by merging both routines. Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org> Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08workqueue: allow rescuer thread to do more work.NeilBrown
When there is serious memory pressure, all workers in a pool could be blocked, and a new thread cannot be created because it requires memory allocation. In this situation a WQ_MEM_RECLAIM workqueue will wake up the rescuer thread to do some work. The rescuer will only handle requests that are already on ->worklist. If max_requests is 1, that means it will handle a single request. The rescuer will be woken again in 100ms to handle another max_requests requests. I've seen a machine (running a 3.0 based "enterprise" kernel) with thousands of requests queued for xfslogd, which has a max_requests of 1, and is needed for retiring all 'xfs' write requests. When one of the worker pools gets into this state, it progresses extremely slowly and possibly never recovers (only waited an hour or two). With this patch we leave a pool_workqueue on mayday list until it is clearly no longer in need of assistance. This allows all requests to be handled in a timely fashion. We keep each pool_workqueue on the mayday list until need_to_create_worker() is false, and no work for this workqueue is found in the pool. I have tested this in combination with a (hackish) patch which forces all work items to be handled by the rescuer thread. In that context it significantly improves performance. A similar patch for a 3.0 kernel significantly improved performance on a heavy work load. Thanks to Jan Kara for some design ideas, and to Dongsu Park for some comments and testing. tj: Inverted the lock order between wq_mayday_lock and pool->lock with a preceding patch and simplified this patch. Added comment and updated changelog accordingly. Dongsu spotted missing get_pwq() in the simplified code. Cc: Dongsu Park <dongsu.park@profitbricks.com> Cc: Jan Kara <jack@suse.cz> Cc: Lai Jiangshan <laijs@cn.fujitsu.com> Signed-off-by: NeilBrown <neilb@suse.de> Signed-off-by: Tejun Heo <tj@kernel.org>
2014-12-08workqueue: invert the order between pool->lock and wq_mayday_lockTejun Heo
Currently, pool->lock nests inside pool->lock. There's no inherent reason for this order. The only place where the two locks are held together is pool_mayday_timeout() and it just got decided that way. This nesting order turns out to complicate things with the planned rescuer_thread() update. Let's invert them. This doesn't cause any behavior differences. Signed-off-by: Tejun Heo <tj@kernel.org> Reviewed-by: Lai Jiangshan <laijs@cn.fujitsu.com> Cc: NeilBrown <neilb@suse.de> Cc: Dongsu Park <dongsu.park@profitbricks.com>
2014-12-08Merge branch 'at91/cleanup5' into next/driversArnd Bergmann
The at91 cleanups changed a lot of files, this merges in the latest cleanups to resolve the conflicts Conflicts: arch/arm/mach-at91/at91sam9260.c arch/arm/mach-at91/at91sam9261.c arch/arm/mach-at91/at91sam9263.c arch/arm/mach-at91/clock.c arch/arm/mach-at91/clock.h drivers/rtc/Kconfig Signed-off-by: Arnd Bergmann <arnd@arndb.de>
2014-12-08Merge branch 'brcm/stb-smp-uart' into next/driversArnd Bergmann
This resolves a nonobvious merge conflict that I got wrong the first time. * brcm/stb-smp-uart: bus: brcmstb_gisb: save and restore GISB timeout bus: brcmstb_gisb: register the fault code hook ARM: brcmstb: Kconfig: drop unneeded symbol selections ARM: brcmstb: reintroduce SMP support ARM: brcmstb: add debug UART for earlyprintk support Conflicts: drivers/bus/brcmstb_gisb.c Signed-off-by: Arnd Bergmann <arnd@arndb.de> Reported-by: Florian Fainelli <f.fainelli@gmail.com>
2014-12-08thermal: cpu_cooling: initialize 'cpufreq_val' on registrationViresh Kumar
There is no point checking for validity of 'cpufreq_val' from cpufreq_thermal_notifier() every time the routine is called. Its guaranteed to be 0 on the first call but will be valid otherwise. Lets update it once while the device registers. Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org> Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08thermal: cpu_cooling: do error handling at the bottom in ↵Viresh Kumar
__cpufreq_cooling_register() This makes life easy and bug free. And is scalable for future resource allocations. Acked-by: Javi Merino <javi.merino@arm.com> Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org> Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08thermal: cpu_cooling: Don't check is_cpufreq_valid()Viresh Kumar
Because get_cpu_frequency() has returned a valid frequency, it means that the cpufreq policy is surely valid and so no point checking that again with is_cpufreq_valid(). Get rid of the routine as well as there are no more users. Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org> Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08thermal: cpu_cooling: don't iterate over all allowed_cpus to update cpufreq ↵Viresh Kumar
policy All CPUs present in 'allowed_cpus' share the same 'struct cpufreq_policy' structure and so calling cpufreq_update_policy() for each of them doesn't make sense. Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org> Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08thermal: cpu_cooling: Don't match min/max frequencies for all CPUs on ↵Viresh Kumar
cooling register In __cpufreq_cooling_register() we try to match min/max frequencies for all CPUs passed in 'clip_cpus' mask. This mask is the cpumask of cpus where the frequency constraints will be applied. Same frequency constraint can be applied only to the CPUs belonging to the same cluster (i.e. CPUs sharing clock line). For all such CPUs we have a single 'struct cpufreq_policy' structure managing them and so getting policies for all CPUs wouldn't make any sense as they will all return the same pointer. So, remove this useless check of checking min/max for all CPUs. Also update doc comment to make this more obvious that clip_cpus should be same as policy->related_cpus. Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org> Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08thermal: cpu_cooling: propagate error returned by idr_alloc()Viresh Kumar
We aren't supposed to return our own error type here. Return what we got. Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org> Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08thermal: cpu_cooling: no need to initialze 'ret'Viresh Kumar
ret is initialized before it is used, so no need to set it to 0 in its declaration. Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org> Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08thermal: cpu_cooling: no need to set cpufreq_dev to NULLViresh Kumar
It will be overwritten soon with return value of kzalloc(). Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org> Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08thermal: cpu_cooling: no need to set cpufreq_state to zeroViresh Kumar
Its already zero, we allocated cpufreq_dev with kzalloc. Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org> Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08thermal: cpu_cooling: Pass variable instead of its type to sizeof()Viresh Kumar
Just following coding guidelines here. Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org> Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08thermal: cpu_cooling: Add comment to clarify relation between cooling state ↵Viresh Kumar
and frequency This wasn't explained well anywhere and should be clearly specified. Lets add a top level comment for this. Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org> Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08thermal: cpu_cooling: fix doc comment over struct cpufreq_cooling_deviceViresh Kumar
cooling_cpufreq_lock isn't used to protect this structure and so the comment over it is outdated. Fix it. Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org> Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08thermal: cpu_cooling: random comment fixupsViresh Kumar
s/give/given Acked-by: Eduardo Valentin <edubezval@gmail.com> Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org> Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08thermal: exynos: pass cpu_present_mask to cpufreq_cooling_register()Viresh Kumar
cpufreq_cooling_register() expects mask of all the CPUs where frequency constraint is applicable. This platform has more than one CPU to which these constraints will apply and so passing mask of only CPU0 wouldn't be sufficient. Also, this platform has a single cluster of CPUs and the constraint applies to all CPUs. If CPU0 is hoplugged out then we may face strange BUGs as cpu_cooling framework isn't aware of any siblings sharing clock line. Fix it by passing cpu_present_mask to cpufreq_cooling_register(). Cc: Chanwoo Choi <cw00.choi@samsung.com> Cc: Kyungmin Park <kyungmin.park@samsung.com> Cc: Amit Daniel Kachhap <amit.daniel@samsung.com> Cc: Lukasz Majewski <l.majewski@samsung.com> Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org> Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08thermal: imx: pass cpu_present_mask to cpufreq_cooling_register()Viresh Kumar
cpufreq_cooling_register() expects mask of all the CPUs where frequency constraint is applicable. This platform has more than one CPU to which these constraints will apply and so passing mask of only CPU0 wouldn't be sufficient. Also, this platform has a single cluster of CPUs and the constraint applies to all CPUs. If CPU0 is hoplugged out then we may face strange BUGs as cpu_cooling framework isn't aware of any siblings sharing clock line. Fix it by passing cpu_present_mask to cpufreq_cooling_register(). Cc: Shawn Guo <shawn.guo@linaro.org> Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org> Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08thermal: db8500: pass cpu_present_mask to cpufreq_cooling_register()Viresh Kumar
cpufreq_cooling_register() expects mask of all the CPUs where frequency constraint is applicable. This platform has more than one CPU to which these constraints will apply and so passing mask of only CPU0 wouldn't be sufficient. Also, this platform has a single cluster of CPUs and the constraint applies to all CPUs. If CPU0 is hoplugged out then we may face strange BUGs as cpu_cooling framework isn't aware of any siblings sharing clock line. Fix it by passing cpu_present_mask to cpufreq_cooling_register(). Cc: Hongbo Zhang <hongbo.zhang@linaro.com> Cc: Linus Walleij <linus.walleij@linaro.org> Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org> Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08thermal: cpu_cooling: check for the readiness of cpufreq layerEduardo Valentin
In this patch, the cpu_cooling code checks for the usability of cpufreq layer before proceeding with the CPU cooling device registration. The main reason is: CPU cooling device is not usable if cpufreq cannot switch frequencies. Similar checks are spread in thermal drivers. Thus, the advantage now is to have the check in a single place: cpu cooling device registration. For this reason, this patch also updates the existing drivers that depend on CPU cooling to simply propagate the error code of the cpu cooling registration call. Therefore, in case cpufreq is not ready, the thermal drivers will still return -EPROBE_DEFER, in an attempt to try again when cpufreq layer gets ready. Cc: devicetree@vger.kernel.org Cc: Grant Likely <grant.likely@linaro.org> Cc: Kukjin Kim <kgene.kim@samsung.com> Cc: linux-arm-kernel@lists.infradead.org Cc: linux-kernel@vger.kernel.org Cc: linux-pm@vger.kernel.org Cc: linux-samsung-soc@vger.kernel.org Cc: Naveen Krishna Chatradhi <ch.naveen@samsung.com> Cc: Rob Herring <robh+dt@kernel.org> Cc: Zhang Rui <rui.zhang@intel.com> Acked-by: Viresh Kumar <viresh.kumar@linaro.org> Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org> Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08blk-mq: re-check for available tags after running the hardware queueJens Axboe
If we run out of tags and have to sleep, we run the hardware queue to kick pending IO into gear. During that run, we may have completed requests, so re-check if we have free tags before going to sleep. Signed-off-by: Jens Axboe <axboe@fb.com>
2014-12-08blk-mq: fix hang in bt_get()Bart Van Assche
Avoid that if there are fewer hardware queues than CPU threads that bt_get() can hang. The symptoms of the hang were as follows: * All tags allocated for a particular hardware queue. * (nr_tags) pending commands for that hardware queue. * No pending commands for the software queues associated with that hardware queue. Signed-off-by: Jens Axboe <axboe@fb.com>
2014-12-08Merge remote-tracking branch 'scsi-queue/drivers-for-3.19' into for-linusJames Bottomley
Conflicts: drivers/scsi/scsi_debug.c Agreed and tested resolution to a merge problem between a fix in scsi_debug and a driver update Signed-off-by: James Bottomley <JBottomley@Parallels.com>
2014-12-08Merge remote-tracking branch 'scsi-queue/core-for-3.19' into for-linusJames Bottomley
2014-12-08hwmon: (tmp401) Detect TMP435 on all addresses it supportsGuenter Roeck
TMP435 supports a range of I2C addresses, not just 0x4c. Cc: Patrick Titiano <ptitiano@baylibre.com> Cc: Bartosz Golaszewski <bgolaszewski@baylibre.com> Reviewed-by: Jean Delvare <jdelvare@suse.de> Signed-off-by: Guenter Roeck <linux@roeck-us.net>