summaryrefslogtreecommitdiff
AgeCommit message (Collapse)Author
2021-08-11vmlinux.lds.h: Handle clang's module.{c,d}tor sectionsNathan Chancellor
A recent change in LLVM causes module_{c,d}tor sections to appear when CONFIG_K{A,C}SAN are enabled, which results in orphan section warnings because these are not handled anywhere: ld.lld: warning: arch/x86/pci/built-in.a(legacy.o):(.text.asan.module_ctor) is being placed in '.text.asan.module_ctor' ld.lld: warning: arch/x86/pci/built-in.a(legacy.o):(.text.asan.module_dtor) is being placed in '.text.asan.module_dtor' ld.lld: warning: arch/x86/pci/built-in.a(legacy.o):(.text.tsan.module_ctor) is being placed in '.text.tsan.module_ctor' Fangrui explains: "the function asan.module_ctor has the SHF_GNU_RETAIN flag, so it is in a separate section even with -fno-function-sections (default)". Place them in the TEXT_TEXT section so that these technologies continue to work with the newer compiler versions. All of the KASAN and KCSAN KUnit tests continue to pass after this change. Cc: stable@vger.kernel.org Link: https://github.com/ClangBuiltLinux/linux/issues/1432 Link: https://github.com/llvm/llvm-project/commit/7b789562244ee941b7bf2cefeb3fc08a59a01865 Signed-off-by: Nathan Chancellor <nathan@kernel.org> Reviewed-by: Nick Desaulniers <ndesaulniers@google.com> Reviewed-by: Fangrui Song <maskray@google.com> Acked-by: Marco Elver <elver@google.com> Signed-off-by: Kees Cook <keescook@chromium.org> Link: https://lore.kernel.org/r/20210731023107.1932981-1-nathan@kernel.org
2021-08-11Merge branch 'for-5.14/dax' into libnvdimm-fixesDan Williams
Pick up some small dax cleanups that make some of Ira's follow on work easier.
2021-08-11tools/testing/nvdimm: Fix missing 'fallthrough' warningDan Williams
Use "fallthrough;" to address: tools/testing/nvdimm/test/nfit.c: In function ‘nd_intel_test_finish_query’: tools/testing/nvdimm/test/nfit.c:436:37: warning: this statement may fall through [-Wimplicit-fallthrough=] 436 | fw->missed_activate = false; | ~~~~~~~~~~~~~~~~~~~~^~~~~~~ tools/testing/nvdimm/test/nfit.c:438:9: note: here 438 | case FW_STATE_UPDATED: | ^~~~ Reviewed-by: Jeff Moyer <jmoyer@redhat.com> Link: https://lore.kernel.org/r/162767522046.3313209.14767278726893995797.stgit@dwillia2-desk3.amr.corp.intel.com Signed-off-by: Dan Williams <dan.j.williams@intel.com>
2021-08-11libnvdimm/region: Fix label activation vs errorsDan Williams
There are a few scenarios where init_active_labels() can return without registering deactivate_labels() to run when the region is disabled. In particular label error injection creates scenarios where a DIMM is disabled, but labels on other DIMMs in the region become activated. Arrange for init_active_labels() to always register deactivate_labels(). Reported-by: Krzysztof Kensicki <krzysztof.kensicki@intel.com> Cc: <stable@vger.kernel.org> Fixes: bf9bccc14c05 ("libnvdimm: pmem label sets and namespace instantiation.") Reviewed-by: Jeff Moyer <jmoyer@redhat.com> Link: https://lore.kernel.org/r/162766356450.3223041.1183118139023841447.stgit@dwillia2-desk3.amr.corp.intel.com Signed-off-by: Dan Williams <dan.j.williams@intel.com>
2021-08-11ACPI: NFIT: Fix support for virtual SPA rangesDan Williams
Fix the NFIT parsing code to treat a 0 index in a SPA Range Structure as a special case and not match Region Mapping Structures that use 0 to indicate that they are not mapped. Without this fix some platform BIOS descriptions of "virtual disk" ranges do not result in the pmem driver attaching to the range. Details: In addition to typical persistent memory ranges, the ACPI NFIT may also convey "virtual" ranges. These ranges are indicated by a UUID in the SPA Range Structure of UUID_VOLATILE_VIRTUAL_DISK, UUID_VOLATILE_VIRTUAL_CD, UUID_PERSISTENT_VIRTUAL_DISK, or UUID_PERSISTENT_VIRTUAL_CD. The critical difference between virtual ranges and UUID_PERSISTENT_MEMORY, is that virtual do not support associations with Region Mapping Structures. For this reason the "index" value of virtual SPA Range Structures is allowed to be 0. If a platform BIOS decides to represent NVDIMMs with disconnected "Region Mapping Structures" (range-index == 0), the kernel may falsely associate them with standalone ranges where the "SPA Range Structure Index" is also zero. When this happens the driver may falsely require labels where "virtual disks" are expected to be label-less. I.e. "label-less" is where the namespace-range == region-range and the pmem driver attaches with no user action to create a namespace. Cc: Jacek Zloch <jacek.zloch@intel.com> Cc: Lukasz Sobieraj <lukasz.sobieraj@intel.com> Cc: "Lee, Chun-Yi" <jlee@suse.com> Cc: <stable@vger.kernel.org> Fixes: c2f32acdf848 ("acpi, nfit: treat virtual ramdisk SPA as pmem region") Reported-by: Krzysztof Rusocki <krzysztof.rusocki@intel.com> Reported-by: Damian Bassa <damian.bassa@intel.com> Reviewed-by: Jeff Moyer <jmoyer@redhat.com> Link: https://lore.kernel.org/r/162870796589.2521182.1240403310175570220.stgit@dwillia2-desk3.amr.corp.intel.com Signed-off-by: Dan Williams <dan.j.williams@intel.com>
2021-08-11seccomp: Fix setting loaded filter count during TSYNCHsuan-Chi Kuo
The desired behavior is to set the caller's filter count to thread's. This value is reported via /proc, so this fixes the inaccurate count exposed to userspace; it is not used for reference counting, etc. Signed-off-by: Hsuan-Chi Kuo <hsuanchikuo@gmail.com> Link: https://lore.kernel.org/r/20210304233708.420597-1-hsuanchikuo@gmail.com Co-developed-by: Wiktor Garbacz <wiktorg@google.com> Signed-off-by: Wiktor Garbacz <wiktorg@google.com> Link: https://lore.kernel.org/lkml/20210810125158.329849-1-wiktorg@google.com Signed-off-by: Kees Cook <keescook@chromium.org> Cc: stable@vger.kernel.org Fixes: c818c03b661c ("seccomp: Report number of loaded filters in /proc/$pid/status")
2021-08-11bpf: Add rcu_read_lock in bpf_get_current_[ancestor_]cgroup_id() helpersYonghong Song
Currently, if bpf_get_current_cgroup_id() or bpf_get_current_ancestor_cgroup_id() helper is called with sleepable programs e.g., sleepable fentry/fmod_ret/fexit/lsm programs, a rcu warning may appear. For example, if I added the following hack to test_progs/test_lsm sleepable fentry program test_sys_setdomainname: --- a/tools/testing/selftests/bpf/progs/lsm.c +++ b/tools/testing/selftests/bpf/progs/lsm.c @@ -168,6 +168,10 @@ int BPF_PROG(test_sys_setdomainname, struct pt_regs *regs) int buf = 0; long ret; + __u64 cg_id = bpf_get_current_cgroup_id(); + if (cg_id == 1000) + copy_test++; + ret = bpf_copy_from_user(&buf, sizeof(buf), ptr); if (len == -2 && ret == 0 && buf == 1234) copy_test++; I will hit the following rcu warning: include/linux/cgroup.h:481 suspicious rcu_dereference_check() usage! other info that might help us debug this: rcu_scheduler_active = 2, debug_locks = 1 1 lock held by test_progs/260: #0: ffffffffa5173360 (rcu_read_lock_trace){....}-{0:0}, at: __bpf_prog_enter_sleepable+0x0/0xa0 stack backtrace: CPU: 1 PID: 260 Comm: test_progs Tainted: G O 5.14.0-rc2+ #176 Hardware name: QEMU Standard PC (i440FX + PIIX, 1996), BIOS rel-1.14.0-0-g155821a1990b-prebuilt.qemu.org 04/01/2014 Call Trace: dump_stack_lvl+0x56/0x7b bpf_get_current_cgroup_id+0x9c/0xb1 bpf_prog_a29888d1c6706e09_test_sys_setdomainname+0x3e/0x89c bpf_trampoline_6442469132_0+0x2d/0x1000 __x64_sys_setdomainname+0x5/0x110 do_syscall_64+0x3a/0x80 entry_SYSCALL_64_after_hwframe+0x44/0xae I can get similar warning using bpf_get_current_ancestor_cgroup_id() helper. syzbot reported a similar issue in [1] for syscall program. Helper bpf_get_current_cgroup_id() or bpf_get_current_ancestor_cgroup_id() has the following callchain: task_dfl_cgroup task_css_set task_css_set_check and we have #define task_css_set_check(task, __c) \ rcu_dereference_check((task)->cgroups, \ lockdep_is_held(&cgroup_mutex) || \ lockdep_is_held(&css_set_lock) || \ ((task)->flags & PF_EXITING) || (__c)) Since cgroup_mutex/css_set_lock is not held and the task is not existing and rcu read_lock is not held, a warning will be issued. Note that bpf sleepable program is protected by rcu_read_lock_trace(). The above sleepable bpf programs are already protected by migrate_disable(). Adding rcu_read_lock() in these two helpers will silence the above warning. I marked the patch fixing 95b861a7935b ("bpf: Allow bpf_get_current_ancestor_cgroup_id for tracing") which added bpf_get_current_ancestor_cgroup_id() to tracing programs in 5.14. I think backporting 5.14 is probably good enough as sleepable progrems are not widely used. This patch should fix [1] as well since syscall program is a sleepable program protected with migrate_disable(). [1] https://lore.kernel.org/bpf/0000000000006d5cab05c7d9bb87@google.com/ Fixes: 95b861a7935b ("bpf: Allow bpf_get_current_ancestor_cgroup_id for tracing") Reported-by: syzbot+7ee5c2c09c284495371f@syzkaller.appspotmail.com Signed-off-by: Yonghong Song <yhs@fb.com> Signed-off-by: Andrii Nakryiko <andrii@kernel.org> Link: https://lore.kernel.org/bpf/20210810230537.2864668-1-yhs@fb.com
2021-08-11x86/resctrl: Make resctrl_arch_get_config() return its valueJames Morse
resctrl_arch_get_config() has no return, but does pass a single value back via one of its arguments. Return the value instead. Suggested-by: Borislav Petkov <bp@alien8.de> Signed-off-by: James Morse <james.morse@arm.com> Signed-off-by: Borislav Petkov <bp@suse.de> Link: https://lkml.kernel.org/r/20210811163831.14917-1-james.morse@arm.com
2021-08-11x86/resctrl: Merge the CDP resourcesJames Morse
resctrl uses struct rdt_resource to describe the available hardware resources. The domains of the CDP aliases share a single ctrl_val[] array. The only differences between the struct rdt_hw_resource aliases is the name and conf_type. The name from struct rdt_hw_resource is visible to user-space. To support another architecture, as many user-visible details should be handled in the filesystem parts of the code that is common to all architectures. The name and conf_type go together. Remove conf_type and the CDP aliases. When CDP is supported and enabled, schemata_list_create() can create two schemata using the single resource, generating the CODE/DATA suffix to the schema name itself. This allows the alloc_ctrlval_array() and complications around free()ing the ctrl_val arrays to be removed. Signed-off-by: James Morse <james.morse@arm.com> Signed-off-by: Borislav Petkov <bp@suse.de> Reviewed-by: Jamie Iles <jamie@nuviainc.com> Reviewed-by: Reinette Chatre <reinette.chatre@intel.com> Tested-by: Babu Moger <babu.moger@amd.com> Link: https://lkml.kernel.org/r/20210728170637.25610-25-james.morse@arm.com
2021-08-11x86/resctrl: Expand resctrl_arch_update_domains()'s msr_param rangeJames Morse
resctrl_arch_update_domains() specifies the one closid that has been modified and needs copying to the hardware. resctrl_arch_update_domains() takes a struct rdt_resource and a closid as arguments, but copies all the staged configurations for that closid into the ctrl_val[] array. resctrl_arch_update_domains() is called once per schema, but once the resources and domains are merged, the second call of a L2CODE/L2DATA pair will find no staged configurations, as they were previously applied. The msr_param of the first call only has one index, so would only have update the hardware for the last staged configuration. To avoid a second round of IPIs when changing L2CODE and L2DATA in one go, expand the range of the msr_param if multiple staged configurations are found. Signed-off-by: James Morse <james.morse@arm.com> Signed-off-by: Borislav Petkov <bp@suse.de> Reviewed-by: Reinette Chatre <reinette.chatre@intel.com> Tested-by: Babu Moger <babu.moger@amd.com> Link: https://lkml.kernel.org/r/20210728170637.25610-24-james.morse@arm.com
2021-08-11x86/resctrl: Remove rdt_cdp_peer_get()James Morse
When CDP is enabled, rdt_cdp_peer_get() finds the alternative CODE/DATA resource and returns the alternative domain. This is used to determine if bitmaps overlap when there are aliased entries in the two struct rdt_hw_resources. Now that the ctrl_val[] used by the CODE/DATA resources is the same, the search for an alternate resource/domain is not needed. Replace rdt_cdp_peer_get() with resctrl_peer_type(), which returns the alternative type. This can be passed to resctrl_arch_get_config() with the same resource and domain. Signed-off-by: James Morse <james.morse@arm.com> Signed-off-by: Borislav Petkov <bp@suse.de> Reviewed-by: Jamie Iles <jamie@nuviainc.com> Reviewed-by: Reinette Chatre <reinette.chatre@intel.com> Tested-by: Babu Moger <babu.moger@amd.com> Link: https://lkml.kernel.org/r/20210728170637.25610-23-james.morse@arm.com
2021-08-11x86/resctrl: Merge the ctrl_val arraysJames Morse
Each struct rdt_hw_resource has its own ctrl_val[] array. When CDP is enabled, two resources are in use, each with its own ctrl_val[] array that holds half of the configuration used by hardware. One uses the odd slots, the other the even. rdt_cdp_peer_get() is the helper to find the alternate resource, its domain, and corresponding entry in the other ctrl_val[] array. Once the CDP resources are merged there will be one struct rdt_hw_resource and one ctrl_val[] array for each hardware resource. This will include changes to rdt_cdp_peer_get(), making it hard to bisect any issue. Merge the ctrl_val[] arrays for three CODE/DATA/NONE resources first. Doing this before merging the resources temporarily complicates allocating and freeing the ctrl_val arrays. Add a helper to allocate the ctrl_val array, that returns the value on the L2 or L3 resource if it already exists. This gets removed once the resources are merged, and there really is only one ctrl_val[] array. Signed-off-by: James Morse <james.morse@arm.com> Signed-off-by: Borislav Petkov <bp@suse.de> Reviewed-by: Jamie Iles <jamie@nuviainc.com> Reviewed-by: Reinette Chatre <reinette.chatre@intel.com> Tested-by: Babu Moger <babu.moger@amd.com> Link: https://lkml.kernel.org/r/20210728170637.25610-22-james.morse@arm.com
2021-08-11x86/resctrl: Calculate the index from the configuration typeJames Morse
resctrl uses cbm_idx() to map a closid to an index in the configuration array. This is based on a multiplier and offset that are held in the resource. To merge the resources, the resctrl arch code needs to calculate the index from something else, as there will only be one resource. Decide based on the staged configuration type. This makes the static mult and offset parameters redundant. [ bp: Remove superfluous brackets in get_config_index() ] Signed-off-by: James Morse <james.morse@arm.com> Signed-off-by: Borislav Petkov <bp@suse.de> Reviewed-by: Jamie Iles <jamie@nuviainc.com> Reviewed-by: Reinette Chatre <reinette.chatre@intel.com> Tested-by: Babu Moger <babu.moger@amd.com> Link: https://lkml.kernel.org/r/20210728170637.25610-21-james.morse@arm.com
2021-08-11x86/resctrl: Apply offset correction when config is stagedJames Morse
When resctrl comes to copy the CAT MSR values from the ctrl_val[] array into hardware, it applies an offset adjustment based on the type of the resource. CODE and DATA resources have their closid mapped into an odd/even range. This mapping is based on a property of the resource. This happens once the new control value has been written to the ctrl_val[] array. Once the CDP resources are merged, there will only be a single property that needs to cover both odd/even mappings to the single ctrl_val[] array. The offset adjustment must be applied before the new value is written to the array. Move the logic from cat_wrmsr() to resctrl_arch_update_domains(). The value provided to apply_config() is now an index in the array, not the closid. The parameters provided via struct msr_param are now indexes too. As resctrl's use of closid is a u32, struct msr_param's type is changed to match. With this, the CODE and DATA resources only use the odd or even indexes in the array. This allows the temporary num_closid/2 fixes in domain_setup_ctrlval() and reset_all_ctrls() to be removed. Signed-off-by: James Morse <james.morse@arm.com> Signed-off-by: Borislav Petkov <bp@suse.de> Reviewed-by: Jamie Iles <jamie@nuviainc.com> Reviewed-by: Reinette Chatre <reinette.chatre@intel.com> Tested-by: Babu Moger <babu.moger@amd.com> Link: https://lkml.kernel.org/r/20210728170637.25610-20-james.morse@arm.com
2021-08-11x86/resctrl: Make ctrlval arrays the same sizeJames Morse
The CODE and DATA resources report a num_closid that is half the actual size supported by the hardware. This behaviour is visible to user-space when CDP is enabled. The CODE and DATA resources have their own ctrlval arrays which are half the size of the underlying hardware because num_closid was already adjusted. One holds the odd configurations values, the other even. Before the CDP resources can be merged, the 'half the closids' behaviour needs to be implemented by schemata_list_create(), but this causes the ctrl_val[] array to be full sized. Remove the logic from the architecture specific rdt_get_cdp_config() setup, and add it to schemata_list_create(). Functions that walk all the configurations, such as domain_setup_ctrlval() and reset_all_ctrls(), take num_closid directly from struct rdt_hw_resource also have to halve num_closid as only the lower half of each array is in use. domain_setup_ctrlval() and reset_all_ctrls() both copy struct rdt_hw_resource's num_closid to a struct msr_param. Correct the value here. This is temporary as a subsequent patch will merge all three ctrl_val[] arrays such that when CDP is in use, the CODA/DATA layout in the array matches the hardware. reset_all_ctrls()'s loop over the whole of ctrl_val[] is not touched as this is harmless, and will be required as it is once the resources are merged. Signed-off-by: James Morse <james.morse@arm.com> Signed-off-by: Borislav Petkov <bp@suse.de> Reviewed-by: Jamie Iles <jamie@nuviainc.com> Reviewed-by: Reinette Chatre <reinette.chatre@intel.com> Tested-by: Babu Moger <babu.moger@amd.com> Link: https://lkml.kernel.org/r/20210728170637.25610-19-james.morse@arm.com
2021-08-11x86/resctrl: Pass configuration type to resctrl_arch_get_config()James Morse
The ctrl_val[] array for a struct rdt_hw_resource only holds configurations of one type. The type is implicit. Once the CDP resources are merged, the ctrl_val[] array will hold all the configurations for the hardware resource. When a particular type of configuration is needed, it must be specified explicitly. Pass the expected type from the schema into resctrl_arch_get_config(). Nothing uses this yet, but once a single ctrl_val[] array is used for the three struct rdt_hw_resources that share hardware, the type will be used to return the correct configuration value from the shared array. Signed-off-by: James Morse <james.morse@arm.com> Signed-off-by: Borislav Petkov <bp@suse.de> Reviewed-by: Jamie Iles <jamie@nuviainc.com> Reviewed-by: Reinette Chatre <reinette.chatre@intel.com> Tested-by: Babu Moger <babu.moger@amd.com> Link: https://lkml.kernel.org/r/20210728170637.25610-18-james.morse@arm.com
2021-08-11x86/resctrl: Add a helper to read a closid's configurationJames Morse
Functions like show_doms() reach into the architecture's private structure to retrieve the configuration from the struct rdt_hw_resource. The hardware configuration may look completely different to the values resctrl gets from user-space. The staged configuration and resctrl_arch_update_domains() allow the architecture to convert or translate these values. Resctrl shouldn't read or write the ctrl_val[] values directly. Add a helper to read the current configuration. This will allow another architecture to scale the bitmaps if necessary, and possibly use controls that don't take the user-space control format at all. Of the remaining functions that access ctrl_val[] directly, apply_config() is part of the architecture-specific code, and is called via resctrl_arch_update_domains(). reset_all_ctrls() will be an architecture specific helper. update_mba_bw() manipulates both ctrl_val[], mbps_val[] and the hardware. The mbps_val[] that matches the mba_sc state of the resource is changed, but the other is left unchanged. Abstracting this is the subject of later patches that affect set_mba_sc() too. Signed-off-by: James Morse <james.morse@arm.com> Signed-off-by: Borislav Petkov <bp@suse.de> Reviewed-by: Jamie Iles <jamie@nuviainc.com> Reviewed-by: Reinette Chatre <reinette.chatre@intel.com> Tested-by: Babu Moger <babu.moger@amd.com> Link: https://lkml.kernel.org/r/20210728170637.25610-17-james.morse@arm.com
2021-08-11udf: Get rid of 0-length arrays in struct fileIdentDescJan Kara
Get rid of 0-length arrays in struct fileIdentDesc. This requires a bit of cleaning up as the second variable length array in this structure is often used and the code abuses the fact that the first two arrays have the same type and offset in struct fileIdentDesc. Signed-off-by: Jan Kara <jack@suse.cz>
2021-08-11udf: Get rid of 0-length arraysJan Kara
Declare variable length arrays using [] instead of the old-style declarations using arrays with 0 members. Also comment out entries in structures beyond the first variable length array (we still do keep them in comments as a reminder there are further entries in the structure behind the variable length array). Accessing such entries needs a careful offset math anyway so it is safer to not have them declared. Signed-off-by: Jan Kara <jack@suse.cz>
2021-08-11udf: Remove unused declarationJan Kara
Remove declaration of struct virtualAllocationTable15. It is unused. Signed-off-by: Jan Kara <jack@suse.cz>
2021-08-11udf: Check LVID earlierJan Kara
We were checking validity of LVID entries only when getting implementation use information from LVID in udf_sb_lvidiu(). However if the LVID is suitably corrupted, it can cause problems also to code such as udf_count_free() which doesn't use udf_sb_lvidiu(). So check validity of LVID already when loading it from the disk and just disable LVID altogether when it is not valid. Reported-by: syzbot+7fbfe5fed73ebb675748@syzkaller.appspotmail.com Signed-off-by: Jan Kara <jack@suse.cz>
2021-08-11x86/resctrl: Rename update_domains() to resctrl_arch_update_domains()James Morse
update_domains() merges the staged configuration changes into the arch codes configuration array. Rename to make it clear it is part of the arch code interface to resctrl. Signed-off-by: James Morse <james.morse@arm.com> Signed-off-by: Borislav Petkov <bp@suse.de> Reviewed-by: Jamie Iles <jamie@nuviainc.com> Reviewed-by: Reinette Chatre <reinette.chatre@intel.com> Tested-by: Babu Moger <babu.moger@amd.com> Link: https://lkml.kernel.org/r/20210728170637.25610-16-james.morse@arm.com
2021-08-11x86/resctrl: Allow different CODE/DATA configurations to be stagedJames Morse
Before the CDP resources can be merged, struct rdt_domain will need an array of struct resctrl_staged_config, one per type of configuration. Use the type as an index to the array to ensure that a schema configuration string can't specify the same domain twice. This will allow two schemata to apply configuration changes to one resource. Signed-off-by: James Morse <james.morse@arm.com> Signed-off-by: Borislav Petkov <bp@suse.de> Reviewed-by: Jamie Iles <jamie@nuviainc.com> Reviewed-by: Reinette Chatre <reinette.chatre@intel.com> Tested-by: Babu Moger <babu.moger@amd.com> Link: https://lkml.kernel.org/r/20210728170637.25610-15-james.morse@arm.com
2021-08-11x86/resctrl: Group staged configuration into a separate structJames Morse
When configuration changes are made, the new value is written to struct rdt_domain's new_ctrl field and the have_new_ctrl flag is set. Later new_ctrl is copied to hardware by a call to update_domains(). Once the CDP resources are merged, there will be one new_ctrl field in use by two struct resctrl_schema requiring a per-schema IPI to copy the value to hardware. Move new_ctrl and have_new_ctrl into a new struct resctrl_staged_config. Before the CDP resources can be merged, struct rdt_domain will need an array of these, one per type of configuration. Using the type as an index to the array will ensure that a schema configuration string can't specify the same domain twice. Signed-off-by: James Morse <james.morse@arm.com> Signed-off-by: Borislav Petkov <bp@suse.de> Reviewed-by: Jamie Iles <jamie@nuviainc.com> Reviewed-by: Reinette Chatre <reinette.chatre@intel.com> Tested-by: Babu Moger <babu.moger@amd.com> Link: https://lkml.kernel.org/r/20210728170637.25610-14-james.morse@arm.com
2021-08-11x86/resctrl: Move the schemata names into struct resctrl_schemaJames Morse
resctrl 'info' directories and schema parsing use the schema name. This lives in the struct rdt_resource, and is specified by the architecture code. Once the CDP resources are merged, there will only be one resource (and one name) in use by two schemata. To allow the CDP CODE/DATA property to be the type of configuration the schema uses, the name should also be per-schema. Add a name field to struct resctrl_schema, and use this wherever the schema name is exposed (or read from) user-space. Calculating max_name_width for padding the schemata file also moves as this is visible to user-space. As the names in struct rdt_resource already include the CDP information, schemata_list_create() copies them. schemata_list_create() includes the length of the CDP suffix when calculating max_name_width in preparation for CDP resources being merged. Signed-off-by: James Morse <james.morse@arm.com> Signed-off-by: Borislav Petkov <bp@suse.de> Reviewed-by: Jamie Iles <jamie@nuviainc.com> Reviewed-by: Reinette Chatre <reinette.chatre@intel.com> Tested-by: Babu Moger <babu.moger@amd.com> Link: https://lkml.kernel.org/r/20210728170637.25610-13-james.morse@arm.com
2021-08-11x86/resctrl: Add a helper to read/set the CDP configurationJames Morse
Whether CDP is enabled for a hardware resource like the L3 cache can be found by inspecting the alloc_enabled flags of the L3CODE/L3DATA struct rdt_hw_resources, even if they aren't in use. Once these resources are merged, the flags can't be compared. Whether CDP is enabled needs tracking explicitly. If another architecture is emulating CDP the behaviour may not be per-resource. 'cdp_capable' needs to be visible to resctrl, even if its not in use, as this affects the padding of the schemata table visible to user-space. Add cdp_enabled to struct rdt_hw_resource and cdp_capable to struct rdt_resource. Add resctrl_arch_set_cdp_enabled() to let resctrl enable or disable CDP on a resource. resctrl_arch_get_cdp_enabled() lets it read the current state. Signed-off-by: James Morse <james.morse@arm.com> Signed-off-by: Borislav Petkov <bp@suse.de> Reviewed-by: Jamie Iles <jamie@nuviainc.com> Reviewed-by: Reinette Chatre <reinette.chatre@intel.com> Tested-by: Babu Moger <babu.moger@amd.com> Link: https://lkml.kernel.org/r/20210728170637.25610-12-james.morse@arm.com
2021-08-11x86/resctrl: Swizzle rdt_resource and resctrl_schema in pseudo_lock_regionJames Morse
struct pseudo_lock_region points to the rdt_resource. Once the resources are merged, this won't be unique. The resource name is moving into the schema, so that the filesystem portions of resctrl can generate it. Swap pseudo_lock_region's rdt_resource pointer for a schema pointer. Signed-off-by: James Morse <james.morse@arm.com> Signed-off-by: Borislav Petkov <bp@suse.de> Reviewed-by: Jamie Iles <jamie@nuviainc.com> Reviewed-by: Reinette Chatre <reinette.chatre@intel.com> Tested-by: Babu Moger <babu.moger@amd.com> Link: https://lkml.kernel.org/r/20210728170637.25610-11-james.morse@arm.com
2021-08-11x86/resctrl: Pass the schema to resctrl filesystem functionsJames Morse
Once the CDP resources are merged, there will be two struct resctrl_schema for one struct rdt_resource. CDP becomes a type of configuration that belongs to the schema. Helpers like rdtgroup_cbm_overlaps() need access to the schema to query the configuration (or configurations) based on schema properties. Change these functions to take a struct schema instead of the struct rdt_resource. All the modified functions are part of the filesystem code that will move to /fs/resctrl once it is possible to support a second architecture. Signed-off-by: James Morse <james.morse@arm.com> Signed-off-by: Borislav Petkov <bp@suse.de> Reviewed-by: Jamie Iles <jamie@nuviainc.com> Reviewed-by: Reinette Chatre <reinette.chatre@intel.com> Tested-by: Babu Moger <babu.moger@amd.com> Link: https://lkml.kernel.org/r/20210728170637.25610-10-james.morse@arm.com
2021-08-11x86/resctrl: Add resctrl_arch_get_num_closid()James Morse
To initialise struct resctrl_schema's num_closid, schemata_list_create() reaches into the architectures private structure to retrieve num_closid from the struct rdt_hw_resource. The 'half the closids' behaviour should be part of the filesystem parts of resctrl that are the same on any architecture. struct resctrl_schema's num_closid should include any correction for CDP. Having two properties called num_closid is likely to be confusing when they have different values. Add a helper to read the resource's num_closid from the arch code. This should return the number of closid that the resource supports, regardless of whether CDP is in use. Once the CDP resources are merged, schemata_list_create() can apply the correction itself. Using a type with an obvious size for the arch helper means changing the type of num_closid to u32, which matches the type already used by struct rdtgroup. reset_all_ctrls() does not use resctrl_arch_get_num_closid(), even though it sets up a structure for modifying the hardware. This function will be part of the architecture code, the maximum closid should be the maximum value the hardware has, regardless of the way resctrl is using it. All the uses of num_closid in core.c are naturally part of the architecture specific code. Signed-off-by: James Morse <james.morse@arm.com> Signed-off-by: Borislav Petkov <bp@suse.de> Reviewed-by: Jamie Iles <jamie@nuviainc.com> Reviewed-by: Reinette Chatre <reinette.chatre@intel.com> Tested-by: Babu Moger <babu.moger@amd.com> Link: https://lkml.kernel.org/r/20210728170637.25610-9-james.morse@arm.com
2021-08-11x86/resctrl: Store the effective num_closid in the schemaJames Morse
Struct resctrl_schema holds properties that vary with the style of configuration that resctrl applies to a resource. There are already two values for the hardware's num_closid, depending on whether the architecture presents the L3 or L3CODE/L3DATA resources. As the way CDP changes the number of control groups that resctrl can create is part of the user-space interface, it should be managed by the filesystem parts of resctrl. This allows the architecture code to only describe the value the hardware supports. Add num_closid to resctrl_schema. This is the value seen by the filesystem, which may be different to the maximum value described by the arch code when CDP is enabled. These functions operate on the num_closid value that is exposed to user-space: * rdtgroup_parse_resource() * rdtgroup_schemata_show() * rdt_num_closids_show() * closid_init() Change them to use the schema value instead. schemata_list_create() sets this value, and reaches into the architecture-specific structure to get the value. This will eventually be replaced with a helper. Signed-off-by: James Morse <james.morse@arm.com> Signed-off-by: Borislav Petkov <bp@suse.de> Reviewed-by: Jamie Iles <jamie@nuviainc.com> Reviewed-by: Reinette Chatre <reinette.chatre@intel.com> Tested-by: Babu Moger <babu.moger@amd.com> Link: https://lkml.kernel.org/r/20210728170637.25610-8-james.morse@arm.com
2021-08-11Merge tag 'intel-pinctrl-v5.14-2' of ↵Linus Walleij
gitolite.kernel.org:pub/scm/linux/kernel/git/pinctrl/intel into fixes intel-pinctrl for v5.14-2 * Fix the software mapping of GPIOs on Intel Tiger Lake-H The following is an automated git shortlog grouped by driver: tigerlake: - Fix GPIO mapping for newer version of software
2021-08-11pinctrl: k210: Fix k210_fpioa_probe()Damien Le Moal
In k210_fpioa_probe(), add missing calls to clk_disable_unprepare() in case of error after cenabling the clk and pclk clocks. Also add missing error handling when enabling pclk. Reported-by: kernel test robot <lkp@intel.com> Reported-by: Dan Carpenter <dan.carpenter@oracle.com> Fixes: d4c34d09ab03 ("pinctrl: Add RISC-V Canaan Kendryte K210 FPIOA driver") Cc: <stable@vger.kernel.org> Signed-off-by: Damien Le Moal <damien.lemoal@wdc.com> Link: https://lore.kernel.org/r/20210806004311.52859-1-damien.lemoal@wdc.com Signed-off-by: Linus Walleij <linus.walleij@linaro.org>
2021-08-11smp: Fix all kernel-doc warningsRandy Dunlap
Fix the following warnings: kernel/smp.c:1189: warning: cannot understand function prototype: 'struct smp_call_on_cpu_struct ' kernel/smp.c:788: warning: No description found for return value of 'smp_call_function_single_async' kernel/smp.c:990: warning: Function parameter or member 'wait' not described in 'smp_call_function_many' kernel/smp.c:990: warning: Excess function parameter 'flags' description in 'smp_call_function_many' kernel/smp.c:1198: warning: Function parameter or member 'work' not described in 'smp_call_on_cpu_struct' kernel/smp.c:1198: warning: Function parameter or member 'done' not described in 'smp_call_on_cpu_struct' kernel/smp.c:1198: warning: Function parameter or member 'func' not described in 'smp_call_on_cpu_struct' kernel/smp.c:1198: warning: Function parameter or member 'data' not described in 'smp_call_on_cpu_struct' kernel/smp.c:1198: warning: Function parameter or member 'ret' not described in 'smp_call_on_cpu_struct' kernel/smp.c:1198: warning: Function parameter or member 'cpu' not described in 'smp_call_on_cpu_struct' Signed-off-by: Randy Dunlap <rdunlap@infradead.org> Signed-off-by: Thomas Gleixner <tglx@linutronix.de> Link: https://lore.kernel.org/r/20210810225051.3938-1-rdunlap@infradead.org
2021-08-11genirq: Fix kernel-doc warnings in pm.c, msi.c and ipi.cRandy Dunlap
Fix all kernel-doc warnings in these 3 files and do some simple editing (capitalize acronyms, capitalize Linux). kernel/irq/pm.c:235: warning: expecting prototype for irq_pm_syscore_ops(). Prototype was for irq_pm_syscore_resume() instead kernel/irq/msi.c:530: warning: expecting prototype for __msi_domain_free_irqs(). Prototype was for msi_domain_free_irqs() instead kernel/irq/msi.c:31: warning: No description found for return value of 'alloc_msi_entry' kernel/irq/msi.c:103: warning: No description found for return value of 'msi_domain_set_affinity' kernel/irq/msi.c:288: warning: No description found for return value of 'msi_create_irq_domain' kernel/irq/msi.c:499: warning: No description found for return value of 'msi_domain_alloc_irqs' kernel/irq/msi.c:545: warning: No description found for return value of 'msi_get_domain_info' kernel/irq/ipi.c:264: warning: expecting prototype for ipi_send_mask(). Prototype was for __ipi_send_mask() instead kernel/irq/ipi.c:25: warning: No description found for return value of 'irq_reserve_ipi' kernel/irq/ipi.c:116: warning: No description found for return value of 'irq_destroy_ipi' kernel/irq/ipi.c:163: warning: No description found for return value of 'ipi_get_hwirq' kernel/irq/ipi.c:222: warning: No description found for return value of '__ipi_send_single' kernel/irq/ipi.c:308: warning: No description found for return value of 'ipi_send_single' kernel/irq/ipi.c:329: warning: No description found for return value of 'ipi_send_mask' Signed-off-by: Randy Dunlap <rdunlap@infradead.org> Signed-off-by: Thomas Gleixner <tglx@linutronix.de> Link: https://lore.kernel.org/r/20210810234835.12547-1-rdunlap@infradead.org
2021-08-11genirq/timings: Fix error return code in irq_timings_test_irqs()Zhen Lei
Return a negative error code from the error handling case instead of 0, as done elsewhere in this function. Fixes: f52da98d900e ("genirq/timings: Add selftest for irqs circular buffer") Reported-by: Hulk Robot <hulkci@huawei.com> Signed-off-by: Zhen Lei <thunder.leizhen@huawei.com> Signed-off-by: Thomas Gleixner <tglx@linutronix.de> Link: https://lore.kernel.org/r/20210811093333.2376-1-thunder.leizhen@huawei.com
2021-08-11fsnotify: optimize the case of no marks of any typeAmir Goldstein
Add a simple check in the inline helpers to avoid calling fsnotify() and __fsnotify_parent() in case there are no marks of any type (inode/sb/mount) for an inode's sb, so there can be no objects of any type interested in the event. Link: https://lore.kernel.org/r/20210810151220.285179-5-amir73il@gmail.com Reviewed-by: Matthew Bobrowski <repnop@google.com> Signed-off-by: Amir Goldstein <amir73il@gmail.com> Signed-off-by: Jan Kara <jack@suse.cz>
2021-08-11fsnotify: count all objects with attached connectorsAmir Goldstein
Rename s_fsnotify_inode_refs to s_fsnotify_connectors and count all objects with attached connectors, not only inodes with attached connectors. This will be used to optimize fsnotify() calls on sb without any type of marks. Link: https://lore.kernel.org/r/20210810151220.285179-4-amir73il@gmail.com Signed-off-by: Amir Goldstein <amir73il@gmail.com> Reviewed-by: Matthew Bobrowski <repnop@google.com> Signed-off-by: Jan Kara <jack@suse.cz>
2021-08-11fsnotify: count s_fsnotify_inode_refs for attached connectorsAmir Goldstein
Instead of incrementing s_fsnotify_inode_refs when detaching connector from inode, increment it earlier when attaching connector to inode. Next patch is going to use s_fsnotify_inode_refs to count all objects with attached connectors. Link: https://lore.kernel.org/r/20210810151220.285179-3-amir73il@gmail.com Reviewed-by: Matthew Bobrowski <repnop@google.com> Signed-off-by: Amir Goldstein <amir73il@gmail.com> Signed-off-by: Jan Kara <jack@suse.cz>
2021-08-11fsnotify: replace igrab() with ihold() on attach connectorAmir Goldstein
We must have a reference on inode, so ihold is cheaper. Link: https://lore.kernel.org/r/20210810151220.285179-2-amir73il@gmail.com Reviewed-by: Matthew Bobrowski <repnop@google.com> Signed-off-by: Amir Goldstein <amir73il@gmail.com> Signed-off-by: Jan Kara <jack@suse.cz>
2021-08-11x86/resctrl: Walk the resctrl schema list instead of an arch listJames Morse
When parsing a schema configuration value from user-space, resctrl walks the architectures rdt_resources_all[] array to find a matching struct rdt_resource. Once the CDP resources are merged there will be one resource in use by two schemata. Anything walking rdt_resources_all[] on behalf of a user-space request should walk the list of struct resctrl_schema instead. Change the users of for_each_alloc_enabled_rdt_resource() to walk the schema instead. Schemata were only created for alloc_enabled resources so these two lists are currently equivalent. schemata_list_create() and rdt_kill_sb() are ignored. The first creates the schema list, and will eventually loop over the resource indexes using an arch helper to retrieve the resource. rdt_kill_sb() will eventually make use of an arch 'reset everything' helper. After the filesystem code is moved, rdtgroup_pseudo_locked_in_hierarchy() remains part of the x86 specific hooks to support pseudo lock. This code walks each domain, and still does this after the separate resources are merged. Signed-off-by: James Morse <james.morse@arm.com> Signed-off-by: Borislav Petkov <bp@suse.de> Reviewed-by: Jamie Iles <jamie@nuviainc.com> Reviewed-by: Reinette Chatre <reinette.chatre@intel.com> Tested-by: Babu Moger <babu.moger@amd.com> Link: https://lkml.kernel.org/r/20210728170637.25610-7-james.morse@arm.com
2021-08-11x86/resctrl: Label the resources with their configuration typeJames Morse
The names of resources are used for the schema name presented to user-space. The name used is rooted in a structure provided by the architecture code because the names are different when CDP is enabled. x86 implements this by swapping between two sets of resource structures based on their alloc_enabled flag. The type of configuration in-use is encoded in the name (and cbm_idx_offset). Once the CDP behaviour is moved into the parts of resctrl that will move to /fs/, there will be two struct resctrl_schema for one struct rdt_resource. The schema describes the type of configuration being applied to the resource. The name of the schema should be generated by resctrl, base on the type of configuration. To do this struct resctrl_schema needs to store the type of configuration in use for a schema. Create an enum resctrl_conf_type describing the options, and add it to struct resctrl_schema. The underlying resources are still separate, as cbm_idx_offset is still in use. Temporarily label all the entries in rdt_resources_all[] and copy that value to struct resctrl_schema. Copying the value ensures there is no mismatch while the filesystem parts of resctrl are modified to use the schema. Once the resources are merged, the filesystem code can assign this value based on the schema being created. Signed-off-by: James Morse <james.morse@arm.com> Signed-off-by: Borislav Petkov <bp@suse.de> Reviewed-by: Jamie Iles <jamie@nuviainc.com> Reviewed-by: Reinette Chatre <reinette.chatre@intel.com> Tested-by: Babu Moger <babu.moger@amd.com> Link: https://lkml.kernel.org/r/20210728170637.25610-6-james.morse@arm.com
2021-08-11vdpa/mlx5: Fix queue type selection logicEli Cohen
get_queue_type() comments that splict virtqueue is preferred, however, the actual logic preferred packed virtqueues. Since firmware has not supported packed virtqueues we ended up using split virtqueues as was desired. Since we do not advertise support for packed virtqueues, we add a check to verify split virtqueues are indeed supported. Fixes: 1a86b377aa21 ("vdpa/mlx5: Add VDPA driver for supported mlx5 devices") Signed-off-by: Eli Cohen <elic@nvidia.com> Link: https://lore.kernel.org/r/20210811053759.66752-1-elic@nvidia.com Signed-off-by: Michael S. Tsirkin <mst@redhat.com>
2021-08-11vdpa/mlx5: Avoid destroying MR on empty iotlbEli Cohen
The current code treats an empty iotlb provdied in set_map() as a special case and destroy the memory region object. This must not be done since the virtqueue objects reference this MR. Doing so will cause the driver unload to emit errors and log timeouts caused by the firmware complaining on busy resources. This patch treats an empty iotlb as any other change of mapping. In this case, mlx5_vdpa_create_mr() will fail and the entire set_map() call to fail. This issue has not been encountered before but was seen to occur in a non-official version of qemu. Since qemu is a userspace program, the driver must protect against such case. Fixes: 94abbccdf291 ("vdpa/mlx5: Add shared memory registration code") Signed-off-by: Eli Cohen <elic@nvidia.com> Link: https://lore.kernel.org/r/20210811053713.66658-1-elic@nvidia.com Signed-off-by: Michael S. Tsirkin <mst@redhat.com>
2021-08-11tools/virtio: fix buildMichael S. Tsirkin
We use a spinlock now so add a stub. Ignore bogus uninitialized variable warnings. Signed-off-by: Michael S. Tsirkin <mst@redhat.com>
2021-08-11virtio_ring: pull in spinlock headerMichael S. Tsirkin
we use a spinlock now pull in the correct header to make virtio_ring.c self sufficient. Signed-off-by: Michael S. Tsirkin <mst@redhat.com>
2021-08-11vringh: pull in spinlock headerMichael S. Tsirkin
we use a spinlock now pull in the correct header to make vring.h self sufficient. Signed-off-by: Michael S. Tsirkin <mst@redhat.com>
2021-08-11virtio-blk: Add validation for block size in config spaceXie Yongji
An untrusted device might presents an invalid block size in configuration space. This tries to add validation for it in the validate callback and clear the VIRTIO_BLK_F_BLK_SIZE feature bit if the value is out of the supported range. And we also double check the value in virtblk_probe() in case that it's changed after the validation. Signed-off-by: Xie Yongji <xieyongji@bytedance.com> Link: https://lore.kernel.org/r/20210809101609.148-1-xieyongji@bytedance.com Signed-off-by: Michael S. Tsirkin <mst@redhat.com> Acked-by: Jason Wang <jasowang@redhat.com>
2021-08-11vringh: Use wiov->used to check for read/write desc orderNeeraj Upadhyay
As __vringh_iov() traverses a descriptor chain, it populates each descriptor entry into either read or write vring iov and increments that iov's ->used member. So, as we iterate over a descriptor chain, at any point, (riov/wriov)->used value gives the number of descriptor enteries available, which are to be read or written by the device. As all read iovs must precede the write iovs, wiov->used should be zero when we are traversing a read descriptor. Current code checks for wiov->i, to figure out whether any previous entry in the current descriptor chain was a write descriptor. However, iov->i is only incremented, when these vring iovs are consumed, at a later point, and remain 0 in __vringh_iov(). So, correct the check for read and write descriptor order, to use wiov->used. Acked-by: Jason Wang <jasowang@redhat.com> Reviewed-by: Stefano Garzarella <sgarzare@redhat.com> Signed-off-by: Neeraj Upadhyay <neeraju@codeaurora.org> Link: https://lore.kernel.org/r/1624591502-4827-1-git-send-email-neeraju@codeaurora.org Signed-off-by: Michael S. Tsirkin <mst@redhat.com>
2021-08-11virtio_vdpa: reject invalid vq indicesVincent Whitchurch
Do not call vDPA drivers' callbacks with vq indicies larger than what the drivers indicate that they support. vDPA drivers do not bounds check the indices. Signed-off-by: Vincent Whitchurch <vincent.whitchurch@axis.com> Link: https://lore.kernel.org/r/20210701114652.21956-1-vincent.whitchurch@axis.com Signed-off-by: Michael S. Tsirkin <mst@redhat.com> Acked-by: Jason Wang <jasowang@redhat.com> Reviewed-by: Stefano Garzarella <sgarzare@redhat.com>
2021-08-11vdpa: Add documentation for vdpa_alloc_device() macroXie Yongji
The return value of vdpa_alloc_device() macro is not very clear, so that most of callers did the wrong check. Let's add some comments to better document it. Signed-off-by: Xie Yongji <xieyongji@bytedance.com> Link: https://lore.kernel.org/r/20210715080026.242-4-xieyongji@bytedance.com Signed-off-by: Michael S. Tsirkin <mst@redhat.com> Acked-by: Jason Wang <jasowang@redhat.com> Reviewed-by: Stefano Garzarella <sgarzare@redhat.com>