summaryrefslogtreecommitdiff
path: root/drivers/net/wireless/wl12xx/sdio.c
AgeCommit message (Collapse)Author
2011-04-04wl12xx: fix module author's email address in the spi and sdio modulesLuciano Coelho
The MODULE_AUTHOR() macro in the main module (wl12xx) has been updated to reflect one of the author's new email address, but the wl12xx_spi and wl12xx_sdio modules haven't been updated. This patches updates them. Signed-off-by: Luciano Coelho <coelho@ti.com> Signed-off-by: John W. Linville <linville@tuxdriver.com>
2011-03-03wl12xx: Switch to level trigger interruptsIdo Yariv
The interrupt of the wl12xx is a level interrupt in nature, since the interrupt line is not auto-reset. However, since resetting the interrupt requires bus transactions, this cannot be done from an interrupt context. Thus, requesting a level interrupt would require to disable the irq and re-enable it after the HW is acknowledged. Since we now request a threaded irq, this can also be done by specifying the IRQF_ONESHOT flag. Triggering on an edge can be problematic in some platforms, if the sampling frequency is not sufficient for detecting very frequent interrupts. In case an interrupt is missed, the driver will hang as the interrupt line will stay high until it is acknowledged by the driver, which will never happen. Fix this by requesting a level triggered interrupt, with the IRQF_ONESHOT flag. Signed-off-by: Ido Yariv <ido@wizery.com> Reviewed-by: Luciano Coelho <coelho@ti.com> Signed-off-by: Luciano Coelho <coelho@ti.com>
2011-03-03wl12xx: Switch to a threaded interrupt handlerIdo Yariv
To achieve maximal throughput, it is very important to react to interrupts as soon as possible. Currently the interrupt handler wakes up a worker for handling interrupts in process context. A cleaner and more efficient design would be to request a threaded interrupt handler. This handler's priority is very high, and can do blocking operations such as SDIO/SPI transactions. Some work can be deferred, mostly calls to mac80211 APIs (ieee80211_rx_ni and ieee80211_tx_status). By deferring such work to a different worker, we can keep the irq handler thread more I/O responsive. In addition, on multi-core systems the two threads can be scheduled on different cores, which will improve overall performance. The use of WL1271_FLAG_IRQ_PENDING & WL1271_FLAG_IRQ_RUNNING was changed. For simplicity, always query the FW for more pending interrupts. Since there are relatively long bursts of interrupts, the extra FW status read overhead is negligible. In addition, this enables registering the IRQ handler with the ONESHOT option. Signed-off-by: Ido Yariv <ido@wizery.com> Reviewed-by: Luciano Coelho <coelho@ti.com> Signed-off-by: Luciano Coelho <coelho@ti.com>
2011-03-03wl12xx: Change claiming of the SDIO busIdo Yariv
The SDIO bus is claimed and released for each SDIO transaction. In addition to the few CPU cycles it takes to claim and release the bus, it may also cause undesired side effects such as the MMC host stopping its internal clocks. Since only the wl12xx_sdio driver drives this SDIO card, it is safe to claim the SDIO host once (on power on), and release it only when turning the power off. This patch was inspired by Juuso Oikarinen's (juuso.oikarinen@nokia.com) patch "wl12xx: Change claiming of the (SDIO) bus". Signed-off-by: Ido Yariv <ido@wizery.com> Reviewed-by: Luciano Coelho <coelho@ti.com> Signed-off-by: Luciano Coelho <coelho@ti.com>
2011-03-03wl12xx: Don't rely on runtime PM for toggling powerIdo Yariv
Runtime PM might not always be enabled. Even if it is enabled in the running kernel, it can still be temporarily disabled, for instance during suspend. Runtime PM is opportunistic in nature, and should not be relied on for toggling power. In case the interface is removed and re-added while runtime PM is disabled, the FW will fail to boot, as it is mandatory to toggle power between boots. For instance, this can happen during suspend in case one of the devices fails to suspend before the MMC host suspends, but after mac80211 was suspended. The interface will be removed and reactivated without toggling the power. Fix this by calling mmc_power_save_host/mmc_power_restore_host in wl1271_sdio_power_on/off functions. It will toggle the power to the chip even if runtime PM is disabled. The runtime PM functions should still be called to make sure runtime PM does not opportunistically power the chip off (e.g. after resuming from system suspend). Signed-off-by: Ido Yariv <ido@wizery.com> Signed-off-by: Ohad Ben-Cohen <ohad@wizery.com> Signed-off-by: Luciano Coelho <coelho@ti.com>
2011-01-24wl12xx: add missing MODULE_FIRMWARE statment for AP-mode FWArik Nemtsov
In wl12xx cards AP-mode requires a separate FW file. Add this file to the module info. Signed-off-by: Arik Nemtsov <arik@wizery.com> Signed-off-by: Luciano Coelho <coelho@ti.com>
2010-11-22wl1271: Change wl12xx Files NamesShahar Levi
All files name prefix removed due to the fact that wl12xx driver supports wl1271 and wl1273. Also the definition in Kconfig and header files changed respectively. Signed-off-by: Shahar Levi <shahar_levi@ti.com> Signed-off-by: Luciano Coelho <luciano.coelho@nokia.com>