authorWilliam Breathitt Gray <vilhelm.gray@gmail.com>2019-04-02 15:30:41 +0900
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>2019-04-25 21:33:39 +0200
commit7e798ef90c5f7bf934b8a720eeafd0226c5394e7 (patch)
tree06c6904d24072736b1753f0c346f405343721232 /Documentation/ABI
parentf1d8a071d45bf13dd9bb9f1777133ca8a1cafebe (diff)
counter: 104-quad-8: Documentation: Add Generic Counter sysfs documentation
This patch adds standard documentation for the Generic Counter interface userspace sysfs attributes of the 104-QUAD-8 driver. Acked-by: Jonathan Cameron <Jonathan.Cameron@huawei.com> Signed-off-by: William Breathitt Gray <vilhelm.gray@gmail.com> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
Diffstat (limited to 'Documentation/ABI')
-rw-r--r--Documentation/ABI/testing/sysfs-bus-counter-104-quad-836
1 files changed, 36 insertions, 0 deletions
diff --git a/Documentation/ABI/testing/sysfs-bus-counter-104-quad-8 b/Documentation/ABI/testing/sysfs-bus-counter-104-quad-8
new file mode 100644
index 000000000000..46b1f33b2fce
--- /dev/null
+++ b/Documentation/ABI/testing/sysfs-bus-counter-104-quad-8
@@ -0,0 +1,36 @@
+What: /sys/bus/counter/devices/counterX/signalY/index_polarity
+KernelVersion: 5.2
+Contact: linux-iio@vger.kernel.org
+Description:
+ Active level of index input Signal Y; irrelevant in
+ non-synchronous load mode.
+
+What: /sys/bus/counter/devices/counterX/signalY/index_polarity_available
+What: /sys/bus/counter/devices/counterX/signalY/synchronous_mode_available
+KernelVersion: 5.2
+Contact: linux-iio@vger.kernel.org
+Description:
+ Discrete set of available values for the respective Signal Y
+ configuration are listed in this file.
+
+What: /sys/bus/counter/devices/counterX/signalY/synchronous_mode
+KernelVersion: 5.2
+Contact: linux-iio@vger.kernel.org
+Description:
+ Configure the counter associated with Signal Y for
+ non-synchronous or synchronous load mode. Synchronous load mode
+ cannot be selected in non-quadrature (Pulse-Direction) clock
+ mode.
+
+ non-synchronous:
+ A logic low level is the active level at this index
+ input. The index function (as enabled via preset_enable)
+ is performed directly on the active level of the index
+ input.
+
+ synchronous:
+ Intended for interfacing with encoder Index output in
+ quadrature clock mode. The active level is configured
+ via index_polarity. The index function (as enabled via
+ preset_enable) is performed synchronously with the