summaryrefslogtreecommitdiff
path: root/Documentation/devicetree/bindings/iio/temperature
diff options
context:
space:
mode:
authorJonathan Cameron <Jonathan.Cameron@huawei.com>2020-10-31 13:41:06 +0000
committerJonathan Cameron <Jonathan.Cameron@huawei.com>2020-11-16 20:11:26 +0000
commit92af0fb2d443581f8e1c5619d122f3781596ba75 (patch)
tree58298214aeff4e3a50de3920b9cb70fd37969472 /Documentation/devicetree/bindings/iio/temperature
parent39616b4e4a02f54ca2c79a656cb889c476e5d0ba (diff)
dt-bindings:iio:temperature:melexis,mlx90632 conversion to yaml
Technically this could have gone in trivial-devices.yaml, but I have kept it as a separate binding due to the detailed additional description from the text file. Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com> Reviewed-by: Rob Herring <robh@kernel.org> Acked-by: Crt Mori <cmo@melexis.com> Cc: Crt Mori <cmo@melexis.com> Link: https://lore.kernel.org/r/20201031134110.724233-26-jic23@kernel.org
Diffstat (limited to 'Documentation/devicetree/bindings/iio/temperature')
-rw-r--r--Documentation/devicetree/bindings/iio/temperature/melexis,mlx90632.yaml55
-rw-r--r--Documentation/devicetree/bindings/iio/temperature/mlx90632.txt28
2 files changed, 55 insertions, 28 deletions
diff --git a/Documentation/devicetree/bindings/iio/temperature/melexis,mlx90632.yaml b/Documentation/devicetree/bindings/iio/temperature/melexis,mlx90632.yaml
new file mode 100644
index 000000000000..b547ddcd544a
--- /dev/null
+++ b/Documentation/devicetree/bindings/iio/temperature/melexis,mlx90632.yaml
@@ -0,0 +1,55 @@
+# SPDX-License-Identifier: (GPL-2.0 OR BSD-2-Clause)
+%YAML 1.2
+---
+$id: http://devicetree.org/schemas/iio/temperature/melexis,mlx90632.yaml#
+$schema: http://devicetree.org/meta-schemas/core.yaml#
+
+title: Melexis MLX90632 contactless Infra Red temperature sensor
+
+maintainers:
+ - Crt Mori <cmo@melexis.com>
+
+description: |
+ https://www.melexis.com/en/documents/documentation/datasheets/datasheet-mlx90632
+
+ There are various applications for the Infra Red contactless temperature
+ sensor and MLX90632 is most suitable for consumer applications where
+ measured object temperature is in range between -20 to 200 degrees
+ Celsius with relative error of measurement below 1 degree Celsius in
+ object temperature range for industrial applications. Since it can
+ operate and measure ambient temperature in range of -20 to 85 degrees
+ Celsius it is suitable also for outdoor use.
+
+ Be aware that electronics surrounding the sensor can increase ambient
+ temperature. MLX90632 can be calibrated to reduce the housing effect via
+ already existing EEPROM parameters.
+
+ Since measured object emissivity effects Infra Red energy emitted,
+ emissivity should be set before requesting the object temperature.
+
+properties:
+ compatible:
+ const: melexis,mlx90632
+
+ reg:
+ maxItems: 1
+ description: Default is 0x3a, but can be reprogrammed.
+
+required:
+ - compatible
+ - reg
+
+additionalProperties: false
+
+examples:
+ - |
+ i2c {
+ #address-cells = <1>;
+ #size-cells = <0>;
+
+ temp-sensor@3a {
+ compatible = "melexis,mlx90632";
+ reg = <0x3a>;
+ };
+ };
+...
diff --git a/Documentation/devicetree/bindings/iio/temperature/mlx90632.txt b/Documentation/devicetree/bindings/iio/temperature/mlx90632.txt
deleted file mode 100644
index 0b05812001f8..000000000000
--- a/Documentation/devicetree/bindings/iio/temperature/mlx90632.txt
+++ /dev/null
@@ -1,28 +0,0 @@
-* Melexis MLX90632 contactless Infra Red temperature sensor
-
-Link to datasheet: https://www.melexis.com/en/documents/documentation/datasheets/datasheet-mlx90632
-
-There are various applications for the Infra Red contactless temperature sensor
-and MLX90632 is most suitable for consumer applications where measured object
-temperature is in range between -20 to 200 degrees Celsius with relative error
-of measurement below 1 degree Celsius in object temperature range for
-industrial applications. Since it can operate and measure ambient temperature
-in range of -20 to 85 degrees Celsius it is suitable also for outdoor use.
-
-Be aware that electronics surrounding the sensor can increase ambient
-temperature. MLX90632 can be calibrated to reduce the housing effect via
-already existing EEPROM parameters.
-
-Since measured object emissivity effects Infra Red energy emitted, emissivity
-should be set before requesting the object temperature.
-
-Required properties:
- - compatible: should be "melexis,mlx90632"
- - reg: the I2C address of the sensor (default 0x3a)
-
-Example:
-
-mlx90632@3a {
- compatible = "melexis,mlx90632";
- reg = <0x3a>;
-};