authorGuenter Roeck <linux@roeck-us.net>2013-01-10 21:16:47 -0800
committerGuenter Roeck <linux@roeck-us.net>2013-02-06 09:57:57 -0800
commit91bba688016be0ba87ecb9d80d6490c2ebc63b0d (patch)
treef16bbaa5947f88b590f73ff3fb0719610637c475 /Documentation/hwmon/lm73
parentb06367070de3d9f50e4f8f82b92e77ba9a8ebf8f (diff)
hwmon: (lm73) Fix lower and upper temperature limits
While the LM73 is only specified for temperatures from -40 to +150 degrees C, its power-up minimum and maximum temperature limits are -256 and +255.75 degrees C. For better consistency and to avoid confusion, clamp limits to the power-up limits and not to -40 / +150 degrees C. Signed-off-by: Guenter Roeck <linux@roeck-us.net>