ARM: dts: am43xx-epos-evm: Keep DCDC5 and DCDC6 always on
These regulator outputs are needed even in deep sleep modes to prevent low-voltage detection events. Make these always ON to avoid this. Signed-off-by: Kabir Sahane <x0153567@ti.com> Signed-off-by: Andrew F. Davis <afd@ti.com> Signed-off-by: Tony Lindgren <tony@atomide.com>
Diffstat (limited to 'arch/arm/boot/dts/am43x-epos-evm.dts')
-rw-r--r--arch/arm/boot/dts/am43x-epos-evm.dts4
1 files changed, 4 insertions, 0 deletions
diff --git a/arch/arm/boot/dts/am43x-epos-evm.dts b/arch/arm/boot/dts/am43x-epos-evm.dts
index 9dfd80e3b76e..7db5cf3facde 100644
--- a/arch/arm/boot/dts/am43x-epos-evm.dts
+++ b/arch/arm/boot/dts/am43x-epos-evm.dts
@@ -634,12 +634,16 @@
regulator-name = "v1_0bat";
regulator-min-microvolt = <1000000>;
regulator-max-microvolt = <1000000>;
+ regulator-boot-on;
+ regulator-always-on;
};
dcdc6: regulator-dcdc6 {
regulator-name = "v1_8bat";
regulator-min-microvolt = <1800000>;
regulator-max-microvolt = <1800000>;
+ regulator-boot-on;
+ regulator-always-on;
};
ldo1: regulator-ldo1 {