summaryrefslogtreecommitdiff
path: root/arch/powerpc/kernel/trace/ftrace.c
diff options
context:
space:
mode:
authorJordan Niethe <jniethe5@gmail.com>2020-06-02 15:27:25 +1000
committerMichael Ellerman <mpe@ellerman.id.au>2020-07-23 17:41:36 +1000
commit50428fdc53ba48f6936b10dfdc0d644972403908 (patch)
treea82d65170f5ff8f07c1c6e706724efb455e30452 /arch/powerpc/kernel/trace/ftrace.c
parent4f825900786e1c24e4c48622e12eb493a6cd27b6 (diff)
powerpc: Add a ppc_inst_as_str() helper
There are quite a few places where instructions are printed, this is done using a '%x' format specifier. With the introduction of prefixed instructions, this does not work well. Currently in these places, ppc_inst_val() is used for the value for %x so only the first word of prefixed instructions are printed. When the instructions are word instructions, only a single word should be printed. For prefixed instructions both the prefix and suffix should be printed. To accommodate both of these situations, instead of a '%x' specifier use '%s' and introduce a helper, __ppc_inst_as_str() which returns a char *. The char * __ppc_inst_as_str() returns is buffer that is passed to it by the caller. It is cumbersome to require every caller of __ppc_inst_as_str() to now declare a buffer. To make it more convenient to use __ppc_inst_as_str(), wrap it in a macro that uses a compound statement to allocate a buffer on the caller's stack before calling it. Signed-off-by: Jordan Niethe <jniethe5@gmail.com> Reviewed-by: Joel Stanley <joel@jms.id.au> Acked-by: Segher Boessenkool <segher@kernel.crashing.org> [mpe: Drop 0x prefix to match most existings uses, especially xmon] Signed-off-by: Michael Ellerman <mpe@ellerman.id.au> Link: https://lore.kernel.org/r/20200602052728.18227-1-jniethe5@gmail.com
Diffstat (limited to 'arch/powerpc/kernel/trace/ftrace.c')
-rw-r--r--arch/powerpc/kernel/trace/ftrace.c26
1 files changed, 13 insertions, 13 deletions
diff --git a/arch/powerpc/kernel/trace/ftrace.c b/arch/powerpc/kernel/trace/ftrace.c
index c1fede6ec934..42761ebec9f7 100644
--- a/arch/powerpc/kernel/trace/ftrace.c
+++ b/arch/powerpc/kernel/trace/ftrace.c
@@ -73,8 +73,8 @@ ftrace_modify_code(unsigned long ip, struct ppc_inst old, struct ppc_inst new)
/* Make sure it is what we expect it to be */
if (!ppc_inst_equal(replaced, old)) {
- pr_err("%p: replaced (%#x) != old (%#x)",
- (void *)ip, ppc_inst_val(replaced), ppc_inst_val(old));
+ pr_err("%p: replaced (%s) != old (%s)",
+ (void *)ip, ppc_inst_as_str(replaced), ppc_inst_as_str(old));
return -EINVAL;
}
@@ -137,7 +137,7 @@ __ftrace_make_nop(struct module *mod,
/* Make sure that that this is still a 24bit jump */
if (!is_bl_op(op)) {
- pr_err("Not expected bl: opcode is %x\n", ppc_inst_val(op));
+ pr_err("Not expected bl: opcode is %s\n", ppc_inst_as_str(op));
return -EINVAL;
}
@@ -172,8 +172,8 @@ __ftrace_make_nop(struct module *mod,
/* We expect either a mflr r0, or a std r0, LRSAVE(r1) */
if (!ppc_inst_equal(op, ppc_inst(PPC_INST_MFLR)) &&
!ppc_inst_equal(op, ppc_inst(PPC_INST_STD_LR))) {
- pr_err("Unexpected instruction %08x around bl _mcount\n",
- ppc_inst_val(op));
+ pr_err("Unexpected instruction %s around bl _mcount\n",
+ ppc_inst_as_str(op));
return -EINVAL;
}
#else
@@ -203,7 +203,7 @@ __ftrace_make_nop(struct module *mod,
}
if (!ppc_inst_equal(op, ppc_inst(PPC_INST_LD_TOC))) {
- pr_err("Expected %08x found %08x\n", PPC_INST_LD_TOC, ppc_inst_val(op));
+ pr_err("Expected %08x found %s\n", PPC_INST_LD_TOC, ppc_inst_as_str(op));
return -EINVAL;
}
#endif /* CONFIG_MPROFILE_KERNEL */
@@ -231,7 +231,7 @@ __ftrace_make_nop(struct module *mod,
/* Make sure that that this is still a 24bit jump */
if (!is_bl_op(op)) {
- pr_err("Not expected bl: opcode is %x\n", ppc_inst_val(op));
+ pr_err("Not expected bl: opcode is %s\n", ppc_inst_as_str(op));
return -EINVAL;
}
@@ -406,7 +406,7 @@ static int __ftrace_make_nop_kernel(struct dyn_ftrace *rec, unsigned long addr)
/* Make sure that that this is still a 24bit jump */
if (!is_bl_op(op)) {
- pr_err("Not expected bl: opcode is %x\n", ppc_inst_val(op));
+ pr_err("Not expected bl: opcode is %s\n", ppc_inst_as_str(op));
return -EINVAL;
}
@@ -533,8 +533,8 @@ __ftrace_make_call(struct dyn_ftrace *rec, unsigned long addr)
return -EFAULT;
if (!expected_nop_sequence(ip, op[0], op[1])) {
- pr_err("Unexpected call sequence at %p: %x %x\n",
- ip, ppc_inst_val(op[0]), ppc_inst_val(op[1]));
+ pr_err("Unexpected call sequence at %p: %s %s\n",
+ ip, ppc_inst_as_str(op[0]), ppc_inst_as_str(op[1]));
return -EINVAL;
}
@@ -597,7 +597,7 @@ __ftrace_make_call(struct dyn_ftrace *rec, unsigned long addr)
/* It should be pointing to a nop */
if (!ppc_inst_equal(op, ppc_inst(PPC_INST_NOP))) {
- pr_err("Expected NOP but have %x\n", ppc_inst_val(op));
+ pr_err("Expected NOP but have %s\n", ppc_inst_as_str(op));
return -EINVAL;
}
@@ -654,7 +654,7 @@ static int __ftrace_make_call_kernel(struct dyn_ftrace *rec, unsigned long addr)
}
if (!ppc_inst_equal(op, ppc_inst(PPC_INST_NOP))) {
- pr_err("Unexpected call sequence at %p: %x\n", ip, ppc_inst_val(op));
+ pr_err("Unexpected call sequence at %p: %s\n", ip, ppc_inst_as_str(op));
return -EINVAL;
}
@@ -733,7 +733,7 @@ __ftrace_modify_call(struct dyn_ftrace *rec, unsigned long old_addr,
/* Make sure that that this is still a 24bit jump */
if (!is_bl_op(op)) {
- pr_err("Not expected bl: opcode is %x\n", ppc_inst_val(op));
+ pr_err("Not expected bl: opcode is %s\n", ppc_inst_as_str(op));
return -EINVAL;
}