summaryrefslogtreecommitdiff
path: root/drivers/gpu/drm/i915/display/icl_dsi.c
diff options
context:
space:
mode:
authorVille Syrjälä <ville.syrjala@linux.intel.com>2020-11-10 01:12:38 +0200
committerVille Syrjälä <ville.syrjala@linux.intel.com>2020-11-16 21:42:55 +0200
commit3749de07bb11b1cc5ad7ec993d879446adae9505 (patch)
tree93174c7074aea57ad7510e8676a21d9ef9a329c6 /drivers/gpu/drm/i915/display/icl_dsi.c
parentb97fcaeee23c1db1dbfffbfb946a5cceeede5958 (diff)
drm/i915: Use actual readout results for .get_freq()
Currently the DPLL .get_freq() uses pll->state.hw_state which is not the thing we actually read out (except during driver load/resume). Outside of that pll->state.hw_state is just the thing we committed last time around. During state check we just read the thing into crtc_state->dpll_hw_state, so that is what we should use for calculating the DPLL output frequency. I think we used to do this so that the results of the readout were actually used, but somehow it got changed when the .get_freq() refactoring happened. Cc: Imre Deak <imre.deak@intel.com> Signed-off-by: Ville Syrjälä <ville.syrjala@linux.intel.com> Link: https://patchwork.freedesktop.org/patch/msgid/20201109231239.17002-3-ville.syrjala@linux.intel.com Reviewed-by: Imre Deak <imre.deak@intel.com>
Diffstat (limited to 'drivers/gpu/drm/i915/display/icl_dsi.c')
-rw-r--r--drivers/gpu/drm/i915/display/icl_dsi.c3
1 files changed, 2 insertions, 1 deletions
diff --git a/drivers/gpu/drm/i915/display/icl_dsi.c b/drivers/gpu/drm/i915/display/icl_dsi.c
index 096652921453..769bb1b0d543 100644
--- a/drivers/gpu/drm/i915/display/icl_dsi.c
+++ b/drivers/gpu/drm/i915/display/icl_dsi.c
@@ -1496,7 +1496,8 @@ static void gen11_dsi_get_config(struct intel_encoder *encoder,
/* FIXME: adapt icl_ddi_clock_get() for DSI and use that? */
pipe_config->port_clock = intel_dpll_get_freq(i915,
- pipe_config->shared_dpll);
+ pipe_config->shared_dpll,
+ &pipe_config->dpll_hw_state);
pipe_config->hw.adjusted_mode.crtc_clock = intel_dsi->pclk;
if (intel_dsi->dual_link)