diff options
author | Jeroen Hofstee <jhofstee@victronenergy.com> | 2019-10-01 21:01:20 +0000 |
---|---|---|
committer | Marc Kleine-Budde <mkl@pengutronix.de> | 2019-11-04 21:47:21 +0100 |
commit | 23c5a9488f076bab336177cd1d1a366bd8ddf087 (patch) | |
tree | 3564b2b04c72194c2621f24cc050eda9783ab309 /drivers/hwmon | |
parent | 3cb3eaac52c0f145d895f4b6c22834d5f02b8569 (diff) |
can: c_can: D_CAN: c_can_chip_config(): perform a sofware reset on open
When the CAN interface is closed it the hardwre is put in power down
mode, but does not reset the error counters / state. Reset the D_CAN on
open, so the reported state and the actual state match.
According to [1], the C_CAN module doesn't have the software reset.
[1] http://www.bosch-semiconductors.com/media/ip_modules/pdf_2/c_can_fd8/users_manual_c_can_fd8_r210_1.pdf
Signed-off-by: Jeroen Hofstee <jhofstee@victronenergy.com>
Signed-off-by: Marc Kleine-Budde <mkl@pengutronix.de>
Diffstat (limited to 'drivers/hwmon')
0 files changed, 0 insertions, 0 deletions