summaryrefslogtreecommitdiff
path: root/drivers/net/dsa/ocelot/felix_vsc9959.c
diff options
context:
space:
mode:
authorXiaoliang Yang <xiaoliang.yang_1@nxp.com>2022-06-17 11:24:23 +0800
committerDavid S. Miller <davem@davemloft.net>2022-06-19 09:53:59 +0100
commit8670dc33f48bab4d7bb4b8d0232f17f4dae419ec (patch)
treeee153e88e10b3e41b0ace1474dd4e427597f66f1 /drivers/net/dsa/ocelot/felix_vsc9959.c
parentc205035e3adb4c50234c9263f7cf3bbff76b3c72 (diff)
net: dsa: felix: update base time of time-aware shaper when adjusting PTP time
When adjusting the PTP clock, the base time of the TAS configuration will become unreliable. We need reset the TAS configuration by using a new base time. For example, if the driver gets a base time 0 of Qbv configuration from user, and current time is 20000. The driver will set the TAS base time to be 20000. After the PTP clock adjustment, the current time becomes 10000. If the TAS base time is still 20000, it will be a future time, and TAS entry list will stop running. Another example, if the current time becomes to be 10000000 after PTP clock adjust, a large time offset can cause the hardware to hang. This patch introduces a tas_clock_adjust() function to reset the TAS module by using a new base time after the PTP clock adjustment. This can avoid issues above. Due to PTP clock adjustment can occur at any time, it may conflict with the TAS configuration. We introduce a new TAS lock to serialize the access to the TAS registers. Signed-off-by: Xiaoliang Yang <xiaoliang.yang_1@nxp.com> Signed-off-by: David S. Miller <davem@davemloft.net>
Diffstat (limited to 'drivers/net/dsa/ocelot/felix_vsc9959.c')
-rw-r--r--drivers/net/dsa/ocelot/felix_vsc9959.c83
1 files changed, 77 insertions, 6 deletions
diff --git a/drivers/net/dsa/ocelot/felix_vsc9959.c b/drivers/net/dsa/ocelot/felix_vsc9959.c
index 570d0204b7be..dd9085ae0922 100644
--- a/drivers/net/dsa/ocelot/felix_vsc9959.c
+++ b/drivers/net/dsa/ocelot/felix_vsc9959.c
@@ -1196,10 +1196,13 @@ static void vsc9959_tas_gcl_set(struct ocelot *ocelot, const u32 gcl_ix,
static int vsc9959_qos_port_tas_set(struct ocelot *ocelot, int port,
struct tc_taprio_qopt_offload *taprio)
{
+ struct ocelot_port *ocelot_port = ocelot->ports[port];
struct timespec64 base_ts;
int ret, i;
u32 val;
+ mutex_lock(&ocelot->tas_lock);
+
if (!taprio->enable) {
ocelot_rmw_rix(ocelot,
QSYS_TAG_CONFIG_INIT_GATE_STATE(0xFF),
@@ -1207,15 +1210,20 @@ static int vsc9959_qos_port_tas_set(struct ocelot *ocelot, int port,
QSYS_TAG_CONFIG_INIT_GATE_STATE_M,
QSYS_TAG_CONFIG, port);
+ mutex_unlock(&ocelot->tas_lock);
return 0;
}
if (taprio->cycle_time > NSEC_PER_SEC ||
- taprio->cycle_time_extension >= NSEC_PER_SEC)
- return -EINVAL;
+ taprio->cycle_time_extension >= NSEC_PER_SEC) {
+ ret = -EINVAL;
+ goto err;
+ }
- if (taprio->num_entries > VSC9959_TAS_GCL_ENTRY_MAX)
- return -ERANGE;
+ if (taprio->num_entries > VSC9959_TAS_GCL_ENTRY_MAX) {
+ ret = -ERANGE;
+ goto err;
+ }
/* Enable guard band. The switch will schedule frames without taking
* their length into account. Thus we'll always need to enable the
@@ -1236,8 +1244,10 @@ static int vsc9959_qos_port_tas_set(struct ocelot *ocelot, int port,
* config is pending, need reset the TAS module
*/
val = ocelot_read(ocelot, QSYS_PARAM_STATUS_REG_8);
- if (val & QSYS_PARAM_STATUS_REG_8_CONFIG_PENDING)
- return -EBUSY;
+ if (val & QSYS_PARAM_STATUS_REG_8_CONFIG_PENDING) {
+ ret = -EBUSY;
+ goto err;
+ }
ocelot_rmw_rix(ocelot,
QSYS_TAG_CONFIG_ENABLE |
@@ -1248,6 +1258,8 @@ static int vsc9959_qos_port_tas_set(struct ocelot *ocelot, int port,
QSYS_TAG_CONFIG_SCH_TRAFFIC_QUEUES_M,
QSYS_TAG_CONFIG, port);
+ ocelot_port->base_time = taprio->base_time;
+
vsc9959_new_base_time(ocelot, taprio->base_time,
taprio->cycle_time, &base_ts);
ocelot_write(ocelot, base_ts.tv_nsec, QSYS_PARAM_CFG_REG_1);
@@ -1271,9 +1283,67 @@ static int vsc9959_qos_port_tas_set(struct ocelot *ocelot, int port,
!(val & QSYS_TAS_PARAM_CFG_CTRL_CONFIG_CHANGE),
10, 100000);
+err:
+ mutex_unlock(&ocelot->tas_lock);
+
return ret;
}
+static void vsc9959_tas_clock_adjust(struct ocelot *ocelot)
+{
+ struct ocelot_port *ocelot_port;
+ struct timespec64 base_ts;
+ u64 cycletime;
+ int port;
+ u32 val;
+
+ mutex_lock(&ocelot->tas_lock);
+
+ for (port = 0; port < ocelot->num_phys_ports; port++) {
+ val = ocelot_read_rix(ocelot, QSYS_TAG_CONFIG, port);
+ if (!(val & QSYS_TAG_CONFIG_ENABLE))
+ continue;
+
+ ocelot_rmw(ocelot,
+ QSYS_TAS_PARAM_CFG_CTRL_PORT_NUM(port),
+ QSYS_TAS_PARAM_CFG_CTRL_PORT_NUM_M,
+ QSYS_TAS_PARAM_CFG_CTRL);
+
+ ocelot_rmw_rix(ocelot,
+ QSYS_TAG_CONFIG_INIT_GATE_STATE(0xFF),
+ QSYS_TAG_CONFIG_ENABLE |
+ QSYS_TAG_CONFIG_INIT_GATE_STATE_M,
+ QSYS_TAG_CONFIG, port);
+
+ cycletime = ocelot_read(ocelot, QSYS_PARAM_CFG_REG_4);
+ ocelot_port = ocelot->ports[port];
+
+ vsc9959_new_base_time(ocelot, ocelot_port->base_time,
+ cycletime, &base_ts);
+
+ ocelot_write(ocelot, base_ts.tv_nsec, QSYS_PARAM_CFG_REG_1);
+ ocelot_write(ocelot, lower_32_bits(base_ts.tv_sec),
+ QSYS_PARAM_CFG_REG_2);
+ val = upper_32_bits(base_ts.tv_sec);
+ ocelot_rmw(ocelot,
+ QSYS_PARAM_CFG_REG_3_BASE_TIME_SEC_MSB(val),
+ QSYS_PARAM_CFG_REG_3_BASE_TIME_SEC_MSB_M,
+ QSYS_PARAM_CFG_REG_3);
+
+ ocelot_rmw(ocelot, QSYS_TAS_PARAM_CFG_CTRL_CONFIG_CHANGE,
+ QSYS_TAS_PARAM_CFG_CTRL_CONFIG_CHANGE,
+ QSYS_TAS_PARAM_CFG_CTRL);
+
+ ocelot_rmw_rix(ocelot,
+ QSYS_TAG_CONFIG_INIT_GATE_STATE(0xFF) |
+ QSYS_TAG_CONFIG_ENABLE,
+ QSYS_TAG_CONFIG_ENABLE |
+ QSYS_TAG_CONFIG_INIT_GATE_STATE_M,
+ QSYS_TAG_CONFIG, port);
+ }
+ mutex_unlock(&ocelot->tas_lock);
+}
+
static int vsc9959_qos_port_cbs_set(struct dsa_switch *ds, int port,
struct tc_cbs_qopt_offload *cbs_qopt)
{
@@ -2210,6 +2280,7 @@ static const struct ocelot_ops vsc9959_ops = {
.psfp_filter_del = vsc9959_psfp_filter_del,
.psfp_stats_get = vsc9959_psfp_stats_get,
.cut_through_fwd = vsc9959_cut_through_fwd,
+ .tas_clock_adjust = vsc9959_tas_clock_adjust,
};
static const struct felix_info felix_info_vsc9959 = {