summaryrefslogtreecommitdiff
path: root/drivers/net/phy/micrel.c
diff options
context:
space:
mode:
authorDavid S. Miller <davem@davemloft.net>2018-05-21 16:01:54 -0400
committerDavid S. Miller <davem@davemloft.net>2018-05-21 16:01:54 -0400
commit6f6e434aa267a6030477876d89444fe3a6b7a48d (patch)
tree67755c422f1e85451aa646eae21d4c6f3f389d9f /drivers/net/phy/micrel.c
parent44c752fe584d8b9f6e0756ecffa8691677471862 (diff)
parent6741c4bb389da103c0d79ad1961884628900bfe6 (diff)
Merge git://git.kernel.org/pub/scm/linux/kernel/git/davem/net
S390 bpf_jit.S is removed in net-next and had changes in 'net', since that code isn't used any more take the removal. TLS data structures split the TX and RX components in 'net-next', put the new struct members from the bug fix in 'net' into the RX part. The 'net-next' tree had some reworking of how the ERSPAN code works in the GRE tunneling code, overlapping with a one-line headroom calculation fix in 'net'. Overlapping changes in __sock_map_ctx_update_elem(), keep the bits that read the prog members via READ_ONCE() into local variables before using them. Signed-off-by: David S. Miller <davem@davemloft.net>
Diffstat (limited to 'drivers/net/phy/micrel.c')
-rw-r--r--drivers/net/phy/micrel.c31
1 files changed, 31 insertions, 0 deletions
diff --git a/drivers/net/phy/micrel.c b/drivers/net/phy/micrel.c
index de31c5170a5b..3db06b40580d 100644
--- a/drivers/net/phy/micrel.c
+++ b/drivers/net/phy/micrel.c
@@ -573,9 +573,40 @@ static int ksz9031_config_init(struct phy_device *phydev)
ksz9031_of_load_skew_values(phydev, of_node,
MII_KSZ9031RN_TX_DATA_PAD_SKEW, 4,
tx_data_skews, 4);
+
+ /* Silicon Errata Sheet (DS80000691D or DS80000692D):
+ * When the device links in the 1000BASE-T slave mode only,
+ * the optional 125MHz reference output clock (CLK125_NDO)
+ * has wide duty cycle variation.
+ *
+ * The optional CLK125_NDO clock does not meet the RGMII
+ * 45/55 percent (min/max) duty cycle requirement and therefore
+ * cannot be used directly by the MAC side for clocking
+ * applications that have setup/hold time requirements on
+ * rising and falling clock edges.
+ *
+ * Workaround:
+ * Force the phy to be the master to receive a stable clock
+ * which meets the duty cycle requirement.
+ */
+ if (of_property_read_bool(of_node, "micrel,force-master")) {
+ result = phy_read(phydev, MII_CTRL1000);
+ if (result < 0)
+ goto err_force_master;
+
+ /* enable master mode, config & prefer master */
+ result |= CTL1000_ENABLE_MASTER | CTL1000_AS_MASTER;
+ result = phy_write(phydev, MII_CTRL1000, result);
+ if (result < 0)
+ goto err_force_master;
+ }
}
return ksz9031_center_flp_timing(phydev);
+
+err_force_master:
+ phydev_err(phydev, "failed to force the phy to master mode\n");
+ return result;
}
#define KSZ8873MLL_GLOBAL_CONTROL_4 0x06