parent | 9c20899da46b85ed00e6f3b935b4bd9c9b34a571 (diff) |
power: supply: ab8500: Make recharge capacity a constant
The recharge capacity is the hysteresis level for a charger to
restart when a battery does not support maintenance charging.
All products using the AB8500 have batteries supporting
maintenace charging and all code has always set this to 95%.
Turn it into a constant.
Signed-off-by: Linus Walleij <linus.walleij@linaro.org>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
Diffstat (limited to 'drivers/power/supply/ab8500_chargalg.c')
-rw-r--r-- | drivers/power/supply/ab8500_chargalg.c | 10 |
1 files changed, 8 insertions, 2 deletions
diff --git a/drivers/power/supply/ab8500_chargalg.c b/drivers/power/supply/ab8500_chargalg.c index 49e7167d0362..90974a8887cd 100644 --- a/drivers/power/supply/ab8500_chargalg.c +++ b/drivers/power/supply/ab8500_chargalg.c @@ -49,6 +49,13 @@ #define CHARGALG_CURR_STEP_LOW 0 #define CHARGALG_CURR_STEP_HIGH 100 +/* + * This is the battery capacity limit that will trigger a new + * full charging cycle in the case where maintenance charging + * has been disabled + */ +#define AB8500_RECHARGE_CAP 95 + enum ab8500_chargers { NO_CHG, AC_CHG, @@ -1544,8 +1551,7 @@ static void ab8500_chargalg_algorithm(struct ab8500_chargalg *di) fallthrough; case STATE_WAIT_FOR_RECHARGE: - if (di->batt_data.percent <= - di->bm->bat_type->recharge_cap) + if (di->batt_data.percent <= AB8500_RECHARGE_CAP) ab8500_chargalg_state_to(di, STATE_NORMAL_INIT); break; |