summaryrefslogtreecommitdiff
path: root/drivers/thermal/samsung
diff options
context:
space:
mode:
authorBartlomiej Zolnierkiewicz <b.zolnierkie@samsung.com>2018-04-26 13:51:33 +0200
committerEduardo Valentin <edubezval@gmail.com>2018-05-06 16:49:03 -0700
commitb43e3cfe232ab01f7cf1f60179a1d005f62d6cc0 (patch)
treef6f6eea50a4dfbb486f2913237044edb1a29170c /drivers/thermal/samsung
parent2b2426a72702b04fffe359bfbabeec4a4e41d9c7 (diff)
thermal: exynos: remove trip reporting to user-space
Remove trip reporting to user-space - I'm not aware of any user-space program which relies on it and there is a thermal user-space governor which does it in proper way nowadays. Signed-off-by: Bartlomiej Zolnierkiewicz <b.zolnierkie@samsung.com> Reviewed-by: Daniel Lezcano <daniel.lezcano@linaro.org> Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
Diffstat (limited to 'drivers/thermal/samsung')
-rw-r--r--drivers/thermal/samsung/exynos_tmu.c30
1 files changed, 2 insertions, 28 deletions
diff --git a/drivers/thermal/samsung/exynos_tmu.c b/drivers/thermal/samsung/exynos_tmu.c
index 223f9466dfb0..3b20309789e3 100644
--- a/drivers/thermal/samsung/exynos_tmu.c
+++ b/drivers/thermal/samsung/exynos_tmu.c
@@ -216,33 +216,6 @@ struct exynos_tmu_data {
void (*tmu_clear_irqs)(struct exynos_tmu_data *data);
};
-static void exynos_report_trigger(struct exynos_tmu_data *p)
-{
- char data[10], *envp[] = { data, NULL };
- struct thermal_zone_device *tz = p->tzd;
- int temp;
- unsigned int i;
-
- if (!tz) {
- pr_err("No thermal zone device defined\n");
- return;
- }
-
- thermal_zone_device_update(tz, THERMAL_EVENT_UNSPECIFIED);
-
- mutex_lock(&tz->lock);
- /* Find the level for which trip happened */
- for (i = 0; i < of_thermal_get_ntrips(tz); i++) {
- tz->ops->get_trip_temp(tz, i, &temp);
- if (tz->last_temperature < temp)
- break;
- }
-
- snprintf(data, sizeof(data), "%u", i);
- kobject_uevent_env(&tz->device.kobj, KOBJ_CHANGE, envp);
- mutex_unlock(&tz->lock);
-}
-
/*
* TMU treats temperature as a mapped temperature code.
* The temperature is converted differently depending on the calibration type.
@@ -815,7 +788,8 @@ static void exynos_tmu_work(struct work_struct *work)
if (!IS_ERR(data->clk_sec))
clk_disable(data->clk_sec);
- exynos_report_trigger(data);
+ thermal_zone_device_update(data->tzd, THERMAL_EVENT_UNSPECIFIED);
+
mutex_lock(&data->lock);
clk_enable(data->clk);