summaryrefslogtreecommitdiff
path: root/kernel/sched/fair.c
diff options
context:
space:
mode:
authorDietmar Eggemann <dietmar.eggemann@arm.com>2022-07-29 13:13:03 +0200
committerIngo Molnar <mingo@kernel.org>2022-08-02 12:32:45 +0200
commit740cf8a760b73e8375bfb4bedcbe9746183350f9 (patch)
tree32df6e4db3c83a27fa5738b3fb79fcbecfd3a4fb /kernel/sched/fair.c
parent9de1f9c8ca5100a02a2e271bdbde36202e251b4b (diff)
sched/core: Introduce sched_asym_cpucap_active()
Create an inline helper for conditional code to be only executed on asymmetric CPU capacity systems. This makes these (currently ~10 and future) conditions a lot more readable. Signed-off-by: Dietmar Eggemann <dietmar.eggemann@arm.com> Signed-off-by: Ingo Molnar <mingo@kernel.org> Link: https://lore.kernel.org/r/20220729111305.1275158-2-dietmar.eggemann@arm.com
Diffstat (limited to 'kernel/sched/fair.c')
-rw-r--r--kernel/sched/fair.c8
1 files changed, 4 insertions, 4 deletions
diff --git a/kernel/sched/fair.c b/kernel/sched/fair.c
index 914096c5b1ae..41486d9b0911 100644
--- a/kernel/sched/fair.c
+++ b/kernel/sched/fair.c
@@ -4262,7 +4262,7 @@ static inline int task_fits_capacity(struct task_struct *p,
static inline void update_misfit_status(struct task_struct *p, struct rq *rq)
{
- if (!static_branch_unlikely(&sched_asym_cpucapacity))
+ if (!sched_asym_cpucap_active())
return;
if (!p || p->nr_cpus_allowed == 1) {
@@ -6506,7 +6506,7 @@ select_idle_capacity(struct task_struct *p, struct sched_domain *sd, int target)
static inline bool asym_fits_capacity(unsigned long task_util, int cpu)
{
- if (static_branch_unlikely(&sched_asym_cpucapacity))
+ if (sched_asym_cpucap_active())
return fits_capacity(task_util, capacity_of(cpu));
return true;
@@ -6526,7 +6526,7 @@ static int select_idle_sibling(struct task_struct *p, int prev, int target)
* On asymmetric system, update task utilization because we will check
* that the task fits with cpu's capacity.
*/
- if (static_branch_unlikely(&sched_asym_cpucapacity)) {
+ if (sched_asym_cpucap_active()) {
sync_entity_load_avg(&p->se);
task_util = uclamp_task_util(p);
}
@@ -6580,7 +6580,7 @@ static int select_idle_sibling(struct task_struct *p, int prev, int target)
* For asymmetric CPU capacity systems, our domain of interest is
* sd_asym_cpucapacity rather than sd_llc.
*/
- if (static_branch_unlikely(&sched_asym_cpucapacity)) {
+ if (sched_asym_cpucap_active()) {
sd = rcu_dereference(per_cpu(sd_asym_cpucapacity, target));
/*
* On an asymmetric CPU capacity system where an exclusive