summaryrefslogtreecommitdiff
path: root/tools
diff options
context:
space:
mode:
authorAthira Rajeev <atrajeev@linux.vnet.ibm.com>2024-10-10 20:21:06 +0530
committerNamhyung Kim <namhyung@kernel.org>2024-10-17 11:24:52 -0700
commit86f45d0f17d2f4d4857a8553673add9c71fb45aa (patch)
tree4f1427a39ec329bfa60cf9841a8e4c5ba08cc92b /tools
parent05a62936e6b14c005db3b0c9c7d8b93d825dd9ca (diff)
tools/perf/pmu-events/powerpc: Add support for compat events in json
perf list picks the events supported for specific platform from pmu-events/arch/powerpc/<platform>. Example power10 events are in pmu-events/arch/powerpc/power10, power9 events are part of pmu-events/arch/powerpc/power9. The decision of which platform to pick is determined based on PVR value in powerpc. The PVR value is matched from pmu-events/arch/powerpc/mapfile.csv Example: Format: PVR,Version,JSON/file/pathname,Type 0x004[bcd][[:xdigit:]]{4},1,power8,core 0x0066[[:xdigit:]]{4},1,power8,core 0x004e[[:xdigit:]]{4},1,power9,core 0x0080[[:xdigit:]]{4},1,power10,core 0x0082[[:xdigit:]]{4},1,power10,core The code gets the PVR from system using get_cpuid_str function in arch/powerpc/util/headers.c ( from SPRN_PVR ) and compares with value from mapfile.csv In case of compat mode, say when partition is booted in a power9 mode when the system is a power10, add an entry to pick the ISA architected events from "pmu-events/arch/powerpc/compat". Add json file generic-events.json which will contain these events which is supported in compat mode. Suggested-by: Madhavan Srinivasan <maddy@linux.ibm.com> Signed-off-by: Athira Rajeev <atrajeev@linux.vnet.ibm.com> Tested-by: Disha Goel <disgoel@linux.ibm.com> Cc: akanksha@linux.ibm.com Cc: hbathini@linux.ibm.com Cc: kjain@linux.ibm.com Cc: linuxppc-dev@lists.ozlabs.org Link: https://lore.kernel.org/r/20241010145107.51211-1-atrajeev@linux.vnet.ibm.com Signed-off-by: Namhyung Kim <namhyung@kernel.org>
Diffstat (limited to 'tools')
-rw-r--r--tools/perf/pmu-events/arch/powerpc/compat/generic-events.json117
-rw-r--r--tools/perf/pmu-events/arch/powerpc/mapfile.csv1
2 files changed, 118 insertions, 0 deletions
diff --git a/tools/perf/pmu-events/arch/powerpc/compat/generic-events.json b/tools/perf/pmu-events/arch/powerpc/compat/generic-events.json
new file mode 100644
index 000000000000..6f5e8efcb098
--- /dev/null
+++ b/tools/perf/pmu-events/arch/powerpc/compat/generic-events.json
@@ -0,0 +1,117 @@
+[
+ {
+ "EventCode": "0x600F4",
+ "EventName": "PM_CYC",
+ "BriefDescription": "Processor cycles."
+ },
+ {
+ "EventCode": "0x100F2",
+ "EventName": "PM_CYC_INST_CMPL",
+ "BriefDescription": "1 or more ppc insts finished"
+ },
+ {
+ "EventCode": "0x100f4",
+ "EventName": "PM_FLOP_CMPL",
+ "BriefDescription": "Floating Point Operations Finished."
+ },
+ {
+ "EventCode": "0x100F6",
+ "EventName": "PM_L1_ITLB_MISS",
+ "BriefDescription": "Number of I-ERAT reloads."
+ },
+ {
+ "EventCode": "0x100F8",
+ "EventName": "PM_NO_INST_AVAIL",
+ "BriefDescription": "Number of cycles the ICT has no itags assigned to this thread."
+ },
+ {
+ "EventCode": "0x100fc",
+ "EventName": "PM_LD_CMPL",
+ "BriefDescription": "Load instruction completed."
+ },
+ {
+ "EventCode": "0x200F0",
+ "EventName": "PM_ST_CMPL",
+ "BriefDescription": "Stores completed from S2Q (2nd-level store queue)."
+ },
+ {
+ "EventCode": "0x200F2",
+ "EventName": "PM_INST_DISP",
+ "BriefDescription": "PowerPC instruction dispatched."
+ },
+ {
+ "EventCode": "0x200F4",
+ "EventName": "PM_RUN_CYC",
+ "BriefDescription": "Processor cycles gated by the run latch."
+ },
+ {
+ "EventCode": "0x200F6",
+ "EventName": "PM_L1_DTLB_RELOAD",
+ "BriefDescription": "DERAT Reloaded due to a DERAT miss."
+ },
+ {
+ "EventCode": "0x200FA",
+ "EventName": "PM_BR_TAKEN_CMPL",
+ "BriefDescription": "Branch Taken instruction completed."
+ },
+ {
+ "EventCode": "0x200FC",
+ "EventName": "PM_L1_ICACHE_MISS",
+ "BriefDescription": "Demand instruction cache miss."
+ },
+ {
+ "EventCode": "0x200FE",
+ "EventName": "PM_L1_RELOAD_FROM_MEM",
+ "BriefDescription": "L1 Dcache reload from memory"
+ },
+ {
+ "EventCode": "0x300F0",
+ "EventName": "PM_ST_MISS_L1",
+ "BriefDescription": "Store Missed L1"
+ },
+ {
+ "EventCode": "0x300FC",
+ "EventName": "PM_DTLB_MISS",
+ "BriefDescription": "Data PTEG reload"
+ },
+ {
+ "EventCode": "0x300FE",
+ "EventName": "PM_DATA_FROM_L3MISS",
+ "BriefDescription": "Demand LD - L3 Miss (not L2 hit and not L3 hit)"
+ },
+ {
+ "EventCode": "0x400F0",
+ "EventName": "PM_LD_MISS_L1",
+ "BriefDescription": "L1 Dcache load miss"
+ },
+ {
+ "EventCode": "0x400F2",
+ "EventName": "PM_CYC_INST_DISP",
+ "BriefDescription": "Cycle when instruction(s) dispatched."
+ },
+ {
+ "EventCode": "0x400F6",
+ "EventName": "PM_BR_MPRED_CMPL",
+ "BriefDescription": "A mispredicted branch completed. Includes direction and target."
+ },
+ {
+ "EventCode": "0x400FA",
+ "EventName": "PM_RUN_INST_CMPL",
+ "BriefDescription": "PowerPC instruction completed while the run latch is set."
+ },
+ {
+ "EventCode": "0x400FC",
+ "EventName": "PM_ITLB_MISS",
+ "BriefDescription": "Instruction TLB reload (after a miss), all page sizes. Includes only demand misses."
+ },
+ {
+ "EventCode": "0x400fe",
+ "EventName": "PM_LD_NOT_CACHED",
+ "BriefDescription": "Load data not cached."
+ },
+ {
+ "EventCode": "0x500fa",
+ "EventName": "PM_INST_CMPL",
+ "BriefDescription": "Instructions."
+ }
+]
diff --git a/tools/perf/pmu-events/arch/powerpc/mapfile.csv b/tools/perf/pmu-events/arch/powerpc/mapfile.csv
index 4d5e9138d4cc..cbd3cb443784 100644
--- a/tools/perf/pmu-events/arch/powerpc/mapfile.csv
+++ b/tools/perf/pmu-events/arch/powerpc/mapfile.csv
@@ -16,3 +16,4 @@
0x004e[[:xdigit:]]{4},1,power9,core
0x0080[[:xdigit:]]{4},1,power10,core
0x0082[[:xdigit:]]{4},1,power10,core
+0x00ffffff,1,compat,core