diff options
Diffstat (limited to 'Documentation/ABI/testing/sysfs-bus-iio-adc-ad7192')
-rw-r--r-- | Documentation/ABI/testing/sysfs-bus-iio-adc-ad7192 | 40 |
1 files changed, 14 insertions, 26 deletions
diff --git a/Documentation/ABI/testing/sysfs-bus-iio-adc-ad7192 b/Documentation/ABI/testing/sysfs-bus-iio-adc-ad7192 index 7627d3be08f5..28be1cabf112 100644 --- a/Documentation/ABI/testing/sysfs-bus-iio-adc-ad7192 +++ b/Documentation/ABI/testing/sysfs-bus-iio-adc-ad7192 @@ -2,38 +2,26 @@ What: /sys/bus/iio/devices/iio:deviceX/ac_excitation_en KernelVersion: Contact: linux-iio@vger.kernel.org Description: - Reading gives the state of AC excitation. - Writing '1' enables AC excitation. + This attribute, if available, is used to enable the AC + excitation mode found on some converters. In ac excitation mode, + the polarity of the excitation voltage is reversed on + alternate cycles, to eliminate DC errors. What: /sys/bus/iio/devices/iio:deviceX/bridge_switch_en KernelVersion: Contact: linux-iio@vger.kernel.org Description: - This bridge switch is used to disconnect it when there is a - need to minimize the system current consumption. - Reading gives the state of the bridge switch. - Writing '1' enables the bridge switch. + This attribute, if available, is used to close or open the + bridge power down switch found on some converters. + In bridge applications, such as strain gauges and load cells, + the bridge itself consumes the majority of the current in the + system. To minimize the current consumption of the system, + the bridge can be disconnected (when it is not being used + using the bridge_switch_en attribute. -What: /sys/bus/iio/devices/iio:deviceX/in_voltagex_sys_calibration +What: /sys/bus/iio/devices/iio:deviceX/in_voltage2-voltage2_shorted_raw KernelVersion: Contact: linux-iio@vger.kernel.org Description: - Initiates the system calibration procedure. This is done on a - single channel at a time. Write '1' to start the calibration. - -What: /sys/bus/iio/devices/iio:deviceX/in_voltagex_sys_calibration_mode_available -KernelVersion: -Contact: linux-iio@vger.kernel.org -Description: - Reading returns a list with the possible calibration modes. - There are two available options: - "zero_scale" - calibrate to zero scale - "full_scale" - calibrate to full scale - -What: /sys/bus/iio/devices/iio:deviceX/in_voltagex_sys_calibration_mode -KernelVersion: -Contact: linux-iio@vger.kernel.org -Description: - Sets up the calibration mode used in the system calibration - procedure. Reading returns the current calibration mode. - Writing sets the system calibration mode. + Measure voltage from AIN2 pin connected to AIN(+) + and AIN(-) shorted. |