diff --git a/Documentation/ABI/testing/sysfs-bus-iio b/Documentation/ABI/testing/sysfs-bus-iio
index 6ad47a67521c..c551301b33f1 100644
--- a/Documentation/ABI/testing/sysfs-bus-iio
+++ b/Documentation/ABI/testing/sysfs-bus-iio
@@ -429,6 +429,7 @@ What: /sys/bus/iio/devices/iio:deviceX/in_angl_scale
What: /sys/bus/iio/devices/iio:deviceX/in_intensity_x_scale
What: /sys/bus/iio/devices/iio:deviceX/in_intensity_y_scale
What: /sys/bus/iio/devices/iio:deviceX/in_intensity_z_scale
+What: /sys/bus/iio/devices/iio:deviceX/in_concentration_co2_scale
KernelVersion: 2.6.35
Contact: linux-iio@vger.kernel.org
Description:
@@ -1957,3 +1958,44 @@ Description:
Specify the percent for light sensor relative to the channel
absolute value that a data field should change before an event
is generated. Units are a percentage of the prior reading.
+
+What: /sys/bus/iio/devices/iio:deviceX/calibration_auto_enable
+Date: June 2020
+KernelVersion: 5.8
+Contact: linux-iio@vger.kernel.org
+Description:
+ Some sensors have the ability to apply auto calibration at
+ runtime. For example, it may be necessary to compensate for
+ contaminant build-up in a measurement chamber or optical
+ element deterioration that would otherwise lead to sensor drift.
+
+ Writing 1 or 0 to this attribute will respectively activate or
+ deactivate this auto calibration function.
+
+ Upon reading, the current status is returned.
+
+What: /sys/bus/iio/devices/iio:deviceX/calibration_forced_value
+Date: June 2020
+KernelVersion: 5.8
+Contact: linux-iio@vger.kernel.org
+Description:
+ Some sensors have the ability to apply a manual calibration using
+ a known measurement value, perhaps obtained from an external
+ reference device.
+
+ Writing a value to this function will force such a calibration
+ change. For the scd30 the value should be from the range
+ [400 1 2000].
+
+ Note for the scd30 that a valid value may only be obtained once
+ it is has been written. Until then any read back of this value
+ should be ignored. As for the scd4x an error will be returned
+ immediately if the manual calibration has failed.
+
+What: /sys/bus/iio/devices/iio:deviceX/calibration_forced_value_available
+KernelVersion: 5.15
+Contact: linux-iio@vger.kernel.org
+Description:
+ Available range for the forced calibration value, expressed as:
+
+ - a range specified as "[min step max]"