diff --git a/Documentation/ABI/testing/debugfs-driver-qat b/Documentation/ABI/testing/debugfs-driver-qat
new file mode 100644
index 000000000000..6731ffacc5f0
--- /dev/null
+++ b/Documentation/ABI/testing/debugfs-driver-qat
@@ -0,0 +1,61 @@
+What: /sys/kernel/debug/qat_<device>_<BDF>/qat/fw_counters
+Date: November 2023
+KernelVersion: 6.6
+Contact: qat-linux@intel.com
+Description: (RO) Read returns the number of requests sent to the FW and the number of responses
+ received from the FW for each Acceleration Engine
+ Reported firmware counters::
+
+ <N>: Number of requests sent from Acceleration Engine N to FW and responses
+ Acceleration Engine N received from FW
+
+What: /sys/kernel/debug/qat_<device>_<BDF>/heartbeat/config
+Date: November 2023
+KernelVersion: 6.6
+Contact: qat-linux@intel.com
+Description: (RW) Read returns value of the Heartbeat update period.
+ Write to the file changes this period value.
+
+ This period should reflect planned polling interval of device
+ health status. High frequency Heartbeat monitoring wastes CPU cycles
+ but minimizes the customer’s system downtime. Also, if there are
+ large service requests that take some time to complete, high frequency
+ Heartbeat monitoring could result in false reports of unresponsiveness
+ and in those cases, period needs to be increased.
+
+ This parameter is effective only for c3xxx, c62x, dh895xcc devices.
+ 4xxx has this value internally fixed to 200ms.
+
+ Default value is set to 500. Minimal allowed value is 200.
+ All values are expressed in milliseconds.
+
+What: /sys/kernel/debug/qat_<device>_<BDF>/heartbeat/queries_failed
+Date: November 2023
+KernelVersion: 6.6
+Contact: qat-linux@intel.com
+Description: (RO) Read returns the number of times the device became unresponsive.
+
+ Attribute returns value of the counter which is incremented when
+ status query results negative.
+
+What: /sys/kernel/debug/qat_<device>_<BDF>/heartbeat/queries_sent
+Date: November 2023
+KernelVersion: 6.6
+Contact: qat-linux@intel.com
+Description: (RO) Read returns the number of times the control process checked
+ if the device is responsive.
+
+ Attribute returns value of the counter which is incremented on
+ every status query.
+
+What: /sys/kernel/debug/qat_<device>_<BDF>/heartbeat/status
+Date: November 2023
+KernelVersion: 6.6
+Contact: qat-linux@intel.com
+Description: (RO) Read returns the device health status.
+
+ Returns 0 when device is healthy or -1 when is unresponsive
+ or the query failed to send.
+
+ The driver does not monitor for Heartbeat. It is left for a user
+ to poll the status periodically.
diff --git a/Documentation/ABI/testing/sysfs-driver-ccp b/Documentation/ABI/testing/sysfs-driver-ccp
index 7aded9b75553..ee6b787eee7a 100644
--- a/Documentation/ABI/testing/sysfs-driver-ccp
+++ b/Documentation/ABI/testing/sysfs-driver-ccp
@@ -85,3 +85,21 @@ Description:
Possible values:
0: Not enforced
1: Enforced
+
+What: /sys/bus/pci/devices/<BDF>/bootloader_version
+Date: June 2023
+KernelVersion: 6.4
+Contact: mario.limonciello@amd.com
+Description:
+ The /sys/bus/pci/devices/<BDF>/bootloader_version
+ file reports the firmware version of the AMD AGESA
+ bootloader.
+
+What: /sys/bus/pci/devices/<BDF>/tee_version
+Date: June 2023
+KernelVersion: 6.4
+Contact: mario.limonciello@amd.com
+Description:
+ The /sys/bus/pci/devices/<BDF>/tee_version
+ file reports the firmware version of the AMD Trusted
+ Execution Environment (TEE).