diff --git a/drivers/thermal/thermal_core.c b/drivers/thermal/thermal_core.c
index 38d393f139d8..31fe14a96d13 100644
--- a/drivers/thermal/thermal_core.c
+++ b/drivers/thermal/thermal_core.c
@@ -602,7 +602,7 @@ struct thermal_zone_device *thermal_zone_get_by_id(int id)
/**
* thermal_zone_bind_cooling_device() - bind a cooling device to a thermal zone
* @tz: pointer to struct thermal_zone_device
- * @trip: indicates which trip point the cooling devices is
+ * @trip_index: indicates which trip point the cooling devices is
* associated with in this thermal zone.
* @cdev: pointer to struct thermal_cooling_device
* @upper: the Maximum cooling state for this trip point.
@@ -622,7 +622,7 @@ struct thermal_zone_device *thermal_zone_get_by_id(int id)
* Return: 0 on success, the proper error value otherwise.
*/
int thermal_zone_bind_cooling_device(struct thermal_zone_device *tz,
- int trip,
+ int trip_index,
struct thermal_cooling_device *cdev,
unsigned long upper, unsigned long lower,
unsigned int weight)
@@ -631,12 +631,15 @@ int thermal_zone_bind_cooling_device(struct thermal_zone_device *tz,
struct thermal_instance *pos;
struct thermal_zone_device *pos1;
struct thermal_cooling_device *pos2;
+ const struct thermal_trip *trip;
bool upper_no_limit;
int result;
- if (trip >= tz->num_trips || trip < 0)
+ if (trip_index >= tz->num_trips || trip_index < 0)
return -EINVAL;
+ trip = &tz->trips[trip_index];
+
list_for_each_entry(pos1, &thermal_tz_list, node) {
if (pos1 == tz)
break;
@@ -739,7 +742,7 @@ EXPORT_SYMBOL_GPL(thermal_zone_bind_cooling_device);
* thermal_zone_unbind_cooling_device() - unbind a cooling device from a
* thermal zone.
* @tz: pointer to a struct thermal_zone_device.
- * @trip: indicates which trip point the cooling devices is
+ * @trip_index: indicates which trip point the cooling devices is
* associated with in this thermal zone.
* @cdev: pointer to a struct thermal_cooling_device.
*
@@ -750,13 +753,15 @@ EXPORT_SYMBOL_GPL(thermal_zone_bind_cooling_device);
* Return: 0 on success, the proper error value otherwise.
*/
int thermal_zone_unbind_cooling_device(struct thermal_zone_device *tz,
- int trip,
+ int trip_index,
struct thermal_cooling_device *cdev)
{
struct thermal_instance *pos, *next;
+ const struct thermal_trip *trip;
mutex_lock(&tz->lock);
mutex_lock(&cdev->lock);
+ trip = &tz->trips[trip_index];
list_for_each_entry_safe(pos, next, &tz->thermal_instances, tz_node) {
if (pos->tz == tz && pos->trip == trip && pos->cdev == cdev) {
list_del(&pos->tz_node);