summaryrefslogtreecommitdiff
path: root/drivers/iio/chemical/ccs811.c
AgeCommit message (Collapse)Author
2017-08-18iio: chemical: ccs811: Add triggered buffer supportNarcisa Ana Maria Vasile
A software trigger such as hrtimer can be used to capture the data that will be stored in the buffer. Cc: Daniel Baluta <daniel.baluta@gmail.com> Cc: Alison Schofield <amsfield22@gmail.com> Signed-off-by: Narcisa Ana Maria Vasile <narcisaanamaria12@gmail.com> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2017-07-22iio: chemical: ccs811: Add support for AMS CCS811 VOC sensorNarcisa Ana Maria Vasile
Add support for CCS811 VOC sensor. This patch adds support for reading current and voltage across the sensor and TVOC and equivalent CO2 values. Scale and offset values have been computed according to datasheet: - For current: raw value is in microamps => 0.001 scale to convert to milliamps - For voltage: 1.65V = 1023, therefore 1650mV = 1023 => 1650.0/1023 = 1.612903 scale to convert to millivolts - For eCO2: raw value range is from 400ppm to 8192ppm. => (val - 400) * (100 - 0) / (8192 - 400) + 0 = (val - 400) * 0.01283367 => offset: -400, scale = 0.012834 to get a percentage value -For TVOC: raw value range is from 0ppb to 1187ppb. => (val - 0) * 100 / (1187 - 0) + 0 = val * 0.0842459 => scale = 0.084246 for getting a percentage value Cc: Daniel Baluta <daniel.baluta@gmail.com> Cc: Alison Schofield <amsfield22@gmail.com> Signed-off-by: Narcisa Ana Maria Vasile <narcisaanamaria12@gmail.com> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>