2019-12-30net: dsa: sja1105: Remove restriction of zero base-time for taprio offloadVladimir Oltean
The check originates from the initial implementation which was not based on PTP time but on a standalone clock source. In the meantime we can now program the PTPSCHTM register at runtime with the dynamic base time (actually with a value that is 200 ns smaller, to avoid writing DELTA=0 in the Schedule Entry Points Parameters Table). And we also have logic for moving the actual base time in the future of the PHC's current time base, so the check for zero serves no purpose, since even if the user will specify zero, that's not what will end up in the static config table where the limitation is. Fixes: 86db36a347b4 ("net: dsa: sja1105: Implement state machine for TAS with PTP clock source") Signed-off-by: Vladimir Oltean <olteanv@gmail.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2019-11-14net: dsa: sja1105: Implement state machine for TAS with PTP clock sourceVladimir Oltean
Tested using the following bash script and the tc from iproute2-next: #!/bin/bash set -e -u -o pipefail NSEC_PER_SEC="1000000000" gatemask() { local tc_list="$1" local mask=0 for tc in ${tc_list}; do mask=$((${mask} | (1 << ${tc}))) done printf "%02x" ${mask} } if ! systemctl is-active --quiet ptp4l; then echo "Please start the ptp4l service" exit fi now=$(phc_ctl /dev/ptp1 get | gawk '/clock time is/ { print $5; }') # Phase-align the base time to the start of the next second. sec=$(echo "${now}" | gawk -F. '{ print $1; }') base_time="$(((${sec} + 1) * ${NSEC_PER_SEC}))" tc qdisc add dev swp5 parent root handle 100 taprio \ num_tc 8 \ map 0 1 2 3 5 6 7 \ queues 1@0 1@1 1@2 1@3 1@4 1@5 1@6 1@7 \ base-time ${base_time} \ sched-entry S $(gatemask 7) 100000 \ sched-entry S $(gatemask "0 1 2 3 4 5 6") 400000 \ clockid CLOCK_TAI flags 2 The "state machine" is a workqueue invoked after each manipulation command on the PTP clock (reset, adjust time, set time, adjust frequency) which checks over the state of the time-aware scheduler. So it is not monitored periodically, only in reaction to a PTP command typically triggered from a userspace daemon (linuxptp). Otherwise there is no reason for things to go wrong. Now that the timecounter/cyclecounter has been replaced with hardware operations on the PTP clock, the TAS Kconfig now depends upon PTP and the standalone clocksource operating mode has been removed. Signed-off-by: Vladimir Oltean <olteanv@gmail.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2019-11-12net: dsa: sja1105: Print the reset reasonVladimir Oltean
Sometimes it can be quite opaque even for me why the driver decided to reset the switch. So instead of adding dump_stack() calls each time for debugging, just add a reset reason to sja1105_static_config_reload calls which gets printed to the console. Signed-off-by: Vladimir Oltean <olteanv@gmail.com> Reviewed-by: Florian Fainelli <f.fainelli@gmail.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2019-09-16net: dsa: sja1105: Configure the Time-Aware Scheduler via tc-taprio offloadVladimir Oltean
This qdisc offload is the closest thing to what the SJA1105 supports in hardware for time-based egress shaping. The switch core really is built around SAE AS6802/TTEthernet (a TTTech standard) but can be made to operate similarly to IEEE 802.1Qbv with some constraints: - The gate control list is a global list for all ports. There are 8 execution threads that iterate through this global list in parallel. I don't know why 8, there are only 4 front-panel ports. - Care must be taken by the user to make sure that two execution threads never get to execute a GCL entry simultaneously. I created a O(n^4) checker for this hardware limitation, prior to accepting a taprio offload configuration as valid. - The spec says that if a GCL entry's interval is shorter than the frame length, you shouldn't send it (and end up in head-of-line blocking). Well, this switch does anyway. - The switch has no concept of ADMIN and OPER configurations. Because it's so simple, the TAS settings are loaded through the static config tables interface, so there isn't even place for any discussion about 'graceful switchover between ADMIN and OPER'. You just reset the switch and upload a new OPER config. - The switch accepts multiple time sources for the gate events. Right now I am using the standalone clock source as opposed to PTP. So the base time parameter doesn't really do much. Support for the PTP clock source will be added in a future series. Signed-off-by: Vladimir Oltean <olteanv@gmail.com> Signed-off-by: David S. Miller <davem@davemloft.net>