summaryrefslogtreecommitdiff
path: root/drivers/power/supply/max1721x_battery.c
AgeCommit message (Collapse)Author
2022-10-01power: supply: max1721x: Fix spelling mistake "Gauage" -> "Gauge"Colin Ian King
There is a spelling mistake in the module description. Fix it. Signed-off-by: Colin Ian King <colin.i.king@gmail.com> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
2021-03-22power: supply: max1721x: Correct spellingXiaofeng Cao
Change 'stanalone' to 'standalone' Change 'mesaurement' to 'measurement' Change 'nonvilatile' to 'nonvolatile' Change 'unical' to 'unique' Change 'unaccesable' to 'unaccessible' Change 'correcpondent' to 'correspond' Signed-off-by: Xiaofeng Cao <caoxiaofeng@yulong.com> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
2020-10-05power: supply: Constify static w1_family_ops structsRikard Falkeborn
The only usage of these structs is to assign their address to the fops field in the w1_family struct, which is a const pointer. Make them const to allow the compiler to put them in read-only memory. This was done with the following Coccinelle semantic patch (http://coccinelle.lip6.fr/): // <smpl> @r1 disable optional_qualifier @ identifier i; position p; @@ static struct w1_family_ops i@p = {...}; @ok1@ identifier r1.i; position p; identifier s; @@ static struct w1_family s = { .fops=&i@p, }; @bad1@ position p!={r1.p,ok1.p}; identifier r1.i; @@ i@p @depends on !bad1 disable optional_qualifier@ identifier r1.i; @@ static +const struct w1_family_ops i={}; // </smpl> Acked-by: Sebastian Reichel <sre@kernel.org> Signed-off-by: Rikard Falkeborn <rikard.falkeborn@gmail.com> Link: https://lore.kernel.org/r/20201004193202.4044-4-rikard.falkeborn@gmail.com Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2018-06-28power: supply: max1721x: fix spelling mistake "RSenese" -> "RSense"Colin Ian King
Trivial fix to spelling mistake in dev_warn message text Signed-off-by: Colin Ian King <colin.king@canonical.com> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk>
2017-07-24power: supply: Add support for MAX1721x standalone fuel gaugeAlex A. Mihaylov
The MAX17211 monitor a single cell pack. The MAX17215 monitor and balance a 2S or 3S pack or monitor a multiple-series cell pack. Both device use 1-Wire interfce. Signed-off-by: Alex A. Mihaylov <minimumlaw@rambler.ru> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk>