From 4284c65a9fda9d31f45209062f1b7f9bb438fc04 Mon Sep 17 00:00:00 2001 From: Wu Hao Date: Mon, 14 Oct 2019 13:42:02 +0800 Subject: fpga: dfl: fme: add thermal management support This patch adds support to thermal management private feature for DFL FPGA Management Engine (FME). This private feature driver registers a hwmon for thermal/temperature monitoring (hwmon temp1_input). If hardware automatic throttling is supported by this hardware, then driver also exposes sysfs interfaces under hwmon for thresholds (temp1_max/ crit/ emergency), threshold alarms (temp1_max_alarm/ temp1_crit_alarm) and throttling policy (temp1_max_policy). Signed-off-by: Luwei Kang Signed-off-by: Russ Weight Signed-off-by: Xu Yilun Signed-off-by: Wu Hao Acked-by: Guenter Roeck Reviewed-by: Moritz Fischer Signed-off-by: Moritz Fischer --- Documentation/ABI/testing/sysfs-platform-dfl-fme | 64 ++++++++++++++++++++++++ 1 file changed, 64 insertions(+) (limited to 'Documentation/ABI') diff --git a/Documentation/ABI/testing/sysfs-platform-dfl-fme b/Documentation/ABI/testing/sysfs-platform-dfl-fme index 72634d3ae4f4..8eb6d03e06e7 100644 --- a/Documentation/ABI/testing/sysfs-platform-dfl-fme +++ b/Documentation/ABI/testing/sysfs-platform-dfl-fme @@ -106,3 +106,67 @@ KernelVersion: 5.4 Contact: Wu Hao Description: Read-only. Read this file to get the second error detected by hardware. + +What: /sys/bus/platform/devices/dfl-fme.0/hwmon/hwmonX/name +Date: October 2019 +KernelVersion: 5.5 +Contact: Wu Hao +Description: Read-Only. Read this file to get the name of hwmon device, it + supports values: + 'dfl_fme_thermal' - thermal hwmon device name + +What: /sys/bus/platform/devices/dfl-fme.0/hwmon/hwmonX/temp1_input +Date: October 2019 +KernelVersion: 5.5 +Contact: Wu Hao +Description: Read-Only. It returns FPGA device temperature in millidegrees + Celsius. + +What: /sys/bus/platform/devices/dfl-fme.0/hwmon/hwmonX/temp1_max +Date: October 2019 +KernelVersion: 5.5 +Contact: Wu Hao +Description: Read-Only. It returns hardware threshold1 temperature in + millidegrees Celsius. If temperature rises at or above this + threshold, hardware starts 50% or 90% throttling (see + 'temp1_max_policy'). + +What: /sys/bus/platform/devices/dfl-fme.0/hwmon/hwmonX/temp1_crit +Date: October 2019 +KernelVersion: 5.5 +Contact: Wu Hao +Description: Read-Only. It returns hardware threshold2 temperature in + millidegrees Celsius. If temperature rises at or above this + threshold, hardware starts 100% throttling. + +What: /sys/bus/platform/devices/dfl-fme.0/hwmon/hwmonX/temp1_emergency +Date: October 2019 +KernelVersion: 5.5 +Contact: Wu Hao +Description: Read-Only. It returns hardware trip threshold temperature in + millidegrees Celsius. If temperature rises at or above this + threshold, a fatal event will be triggered to board management + controller (BMC) to shutdown FPGA. + +What: /sys/bus/platform/devices/dfl-fme.0/hwmon/hwmonX/temp1_max_alarm +Date: October 2019 +KernelVersion: 5.5 +Contact: Wu Hao +Description: Read-only. It returns 1 if temperature is currently at or above + hardware threshold1 (see 'temp1_max'), otherwise 0. + +What: /sys/bus/platform/devices/dfl-fme.0/hwmon/hwmonX/temp1_crit_alarm +Date: October 2019 +KernelVersion: 5.5 +Contact: Wu Hao +Description: Read-only. It returns 1 if temperature is currently at or above + hardware threshold2 (see 'temp1_crit'), otherwise 0. + +What: /sys/bus/platform/devices/dfl-fme.0/hwmon/hwmonX/temp1_max_policy +Date: October 2019 +KernelVersion: 5.5 +Contact: Wu Hao +Description: Read-Only. Read this file to get the policy of hardware threshold1 + (see 'temp1_max'). It only supports two values (policies): + 0 - AP2 state (90% throttling) + 1 - AP1 state (50% throttling) -- cgit