From 8d2453d9a307c2eafd21242dd73f35f05fb7ce74 Mon Sep 17 00:00:00 2001 From: Tony Lindgren Date: Tue, 12 Apr 2022 12:26:51 +0300 Subject: ARM: dts: dra7: Fix suspend warning for vpe powerdomain We currently are getting the following warning after a system suspend: Powerdomain (vpe_pwrdm) didn't enter target state 0 Looks like this is because the STANDBYMODE bit for SMART_IDLE should not be used. The TRM "Table 12-348. VPE_SYSCONFIG" says that the value for SMART_IDLE is "0x2: Same behavior as bit-field value of 0x1". But if the SMART_IDLE value is used, PM_VPE_PWRSTST LASTPOWERSTATEENTERED bits always show value of 3. Let's fix the issue by dropping SMART_IDLE for vpe. And let's also add the missing the powerdomain for vpe. Fixes: 1a2095160594 ("ARM: dts: dra7: Add ti-sysc node for VPE") Cc: Benoit Parrot Reported-by: Kevin Hilman Reviewed-by: Kevin Hilman Tested-by: Kevin Hilman Signed-off-by: Tony Lindgren --- arch/arm/boot/dts/dra7-l4.dtsi | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-) (limited to 'arch/arm') diff --git a/arch/arm/boot/dts/dra7-l4.dtsi b/arch/arm/boot/dts/dra7-l4.dtsi index 0a11bacffc1f..5733e3a4ea8e 100644 --- a/arch/arm/boot/dts/dra7-l4.dtsi +++ b/arch/arm/boot/dts/dra7-l4.dtsi @@ -4188,11 +4188,11 @@ reg = <0x1d0010 0x4>; reg-names = "sysc"; ti,sysc-midle = , - , - ; + ; ti,sysc-sidle = , , ; + power-domains = <&prm_vpe>; clocks = <&vpe_clkctrl DRA7_VPE_VPE_CLKCTRL 0>; clock-names = "fck"; #address-cells = <1>; -- cgit