From 73b08d2aa4245806ef1bdd48463e9a0b045c62cf Mon Sep 17 00:00:00 2001 From: Thomas Gleixner Date: Fri, 16 Feb 2007 01:27:36 -0800 Subject: [PATCH] clocksource: replace is_continuous by a flag field Using a flag filed allows to encode more than one information into a variable. Preparatory patch for the generic clocksource verification. [mingo@elte.hu: convert vmitime.c to the new clocksource flag] Signed-off-by: Thomas Gleixner Signed-off-by: Ingo Molnar Cc: john stultz Cc: Roman Zippel Signed-off-by: Andrew Morton Signed-off-by: Linus Torvalds --- drivers/clocksource/scx200_hrt.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) (limited to 'drivers/clocksource/scx200_hrt.c') diff --git a/drivers/clocksource/scx200_hrt.c b/drivers/clocksource/scx200_hrt.c index 22915cc46ba7..b92da677aa5d 100644 --- a/drivers/clocksource/scx200_hrt.c +++ b/drivers/clocksource/scx200_hrt.c @@ -57,7 +57,7 @@ static struct clocksource cs_hrt = { .rating = 250, .read = read_hrt, .mask = CLOCKSOURCE_MASK(32), - .is_continuous = 1, + .flags = CLOCK_SOURCE_IS_CONTINUOUS, /* mult, shift are set based on mhz27 flag */ }; -- cgit