From 80211be1b9dec04cc2805d3d81e2091ecac289a1 Mon Sep 17 00:00:00 2001 From: Yauhen Kharuzhy Date: Sun, 7 Nov 2021 23:20:01 +0300 Subject: power: bq25890: Enable continuous conversion for ADC at charging Instead of one shot run of ADC at beginning of charging, run continuous conversion to ensure that all charging-related values are monitored properly (input voltage, input current, themperature etc.). Signed-off-by: Yauhen Kharuzhy Reviewed-by: Hans de Goede Signed-off-by: Sebastian Reichel --- drivers/power/supply/bq25890_charger.c | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-) (limited to 'drivers/power') diff --git a/drivers/power/supply/bq25890_charger.c b/drivers/power/supply/bq25890_charger.c index 34ec186a2e9a..b7eac5428083 100644 --- a/drivers/power/supply/bq25890_charger.c +++ b/drivers/power/supply/bq25890_charger.c @@ -581,12 +581,12 @@ static irqreturn_t __bq25890_handle_irq(struct bq25890_device *bq) if (!new_state.online && bq->state.online) { /* power removed */ /* disable ADC */ - ret = bq25890_field_write(bq, F_CONV_START, 0); + ret = bq25890_field_write(bq, F_CONV_RATE, 0); if (ret < 0) goto error; } else if (new_state.online && !bq->state.online) { /* power inserted */ /* enable ADC, to have control of charge current/voltage */ - ret = bq25890_field_write(bq, F_CONV_START, 1); + ret = bq25890_field_write(bq, F_CONV_RATE, 1); if (ret < 0) goto error; } -- cgit