From 1f1496a923b6ba16679074fe77100e1b53cdb880 Mon Sep 17 00:00:00 2001 From: Damien Le Moal Date: Sun, 13 Dec 2020 22:50:35 +0900 Subject: riscv: Fix sifive serial driver Setup the port uartclk in sifive_serial_probe() so that the base baud rate is correctly printed during device probe instead of always showing "0". I.e. the probe message is changed from 38000000.serial: ttySIF0 at MMIO 0x38000000 (irq = 1, base_baud = 0) is a SiFive UART v0 to the correct: 38000000.serial: ttySIF0 at MMIO 0x38000000 (irq = 1, base_baud = 115200) is a SiFive UART v0 Signed-off-by: Damien Le Moal Reviewed-by: Palmer Dabbelt Acked-by: Palmer Dabbelt Signed-off-by: Palmer Dabbelt --- drivers/tty/serial/sifive.c | 1 + 1 file changed, 1 insertion(+) (limited to 'drivers/tty') diff --git a/drivers/tty/serial/sifive.c b/drivers/tty/serial/sifive.c index 1066eebe3b28..328d5a78792f 100644 --- a/drivers/tty/serial/sifive.c +++ b/drivers/tty/serial/sifive.c @@ -1000,6 +1000,7 @@ static int sifive_serial_probe(struct platform_device *pdev) /* Set up clock divider */ ssp->clkin_rate = clk_get_rate(ssp->clk); ssp->baud_rate = SIFIVE_DEFAULT_BAUD_RATE; + ssp->port.uartclk = ssp->baud_rate * 16; __ssp_update_div(ssp); platform_set_drvdata(pdev, ssp); -- cgit