From 35a089b5d793d2bfd2cc7cfa6104545184de2ce7 Mon Sep 17 00:00:00 2001 From: Xin Long Date: Sun, 14 May 2023 15:52:29 -0400 Subject: tipc: check the bearer min mtu properly when setting it by netlink Checking the bearer min mtu with tipc_udp_mtu_bad() only works for IPv4 UDP bearer, and IPv6 UDP bearer has a different value for the min mtu. This patch checks with encap_hlen + TIPC_MIN_BEARER_MTU for min mtu, which works for both IPv4 and IPv6 UDP bearer. Note that tipc_udp_mtu_bad() is still used to check media min mtu in __tipc_nl_media_set(), as m->mtu currently is only used by the IPv4 UDP bearer as its default mtu value. Fixes: 682cd3cf946b ("tipc: confgiure and apply UDP bearer MTU on running links") Signed-off-by: Xin Long Acked-by: Jon Maloy Signed-off-by: David S. Miller --- net/tipc/bearer.c | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-) (limited to 'net/tipc') diff --git a/net/tipc/bearer.c b/net/tipc/bearer.c index 0e9a29e1536b..53881406e200 100644 --- a/net/tipc/bearer.c +++ b/net/tipc/bearer.c @@ -1151,8 +1151,8 @@ int __tipc_nl_bearer_set(struct sk_buff *skb, struct genl_info *info) return -EINVAL; } #ifdef CONFIG_TIPC_MEDIA_UDP - if (tipc_udp_mtu_bad(nla_get_u32 - (props[TIPC_NLA_PROP_MTU]))) { + if (nla_get_u32(props[TIPC_NLA_PROP_MTU]) < + b->encap_hlen + TIPC_MIN_BEARER_MTU) { NL_SET_ERR_MSG(info->extack, "MTU value is out-of-range"); return -EINVAL; -- cgit