summaryrefslogtreecommitdiff
diff options
context:
space:
mode:
authorDimitri Fedrau <dimitri.fedrau@liebherr.com>2025-10-16 07:20:38 +0200
committerJonathan Cameron <Jonathan.Cameron@huawei.com>2025-10-19 11:46:24 +0100
commit7b8dc11c0a830caa0d890c603d597161c6c26095 (patch)
treed9c303fd3dbb05c543453e5d2b24517ae3ee1854
parent3af0c1fb1cdc351b64ff1a4bc06d491490c1f10a (diff)
iio: humditiy: hdc3020: fix units for temperature and humidity measurement
According to the ABI the units after application of scale and offset are milli degrees for temperature measurements and milli percent for relative humidity measurements. Currently the resulting units are degree celsius for temperature measurements and percent for relative humidity measurements. Change scale factor to fix this issue. Fixes: c9180b8e39be ("iio: humidity: Add driver for ti HDC302x humidity sensors") Reported-by: Chris Lesiak <chris.lesiak@licorbio.com> Suggested-by: Chris Lesiak <chris.lesiak@licorbio.com> Reviewed-by: Javier Carrasco <javier.carrasco.cruz@gmail.com> Signed-off-by: Dimitri Fedrau <dimitri.fedrau@liebherr.com> Cc: <Stable@vger.kernel.org> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
-rw-r--r--drivers/iio/humidity/hdc3020.c4
1 files changed, 2 insertions, 2 deletions
diff --git a/drivers/iio/humidity/hdc3020.c b/drivers/iio/humidity/hdc3020.c
index ffb25596d3a8..8aa567d9aded 100644
--- a/drivers/iio/humidity/hdc3020.c
+++ b/drivers/iio/humidity/hdc3020.c
@@ -301,9 +301,9 @@ static int hdc3020_read_raw(struct iio_dev *indio_dev,
case IIO_CHAN_INFO_SCALE:
*val2 = 65536;
if (chan->type == IIO_TEMP)
- *val = 175;
+ *val = 175 * MILLI;
else
- *val = 100;
+ *val = 100 * MILLI;
return IIO_VAL_FRACTIONAL;
case IIO_CHAN_INFO_OFFSET: