summaryrefslogtreecommitdiff
path: root/drivers/scsi/esas2r/atioctl.h
AgeCommit message (Collapse)Author
2022-09-06scsi: esas2r: Use flex array destination for memcpy()Kees Cook
In preparation for FORTIFY_SOURCE performing run-time destination buffer bounds checking for memcpy(), specify the destination output buffer explicitly, instead of asking memcpy() to write past the end of what looked like a fixed-size object. Silences future run-time warning: memcpy: detected field-spanning write (size 80) of single field "trc + 1" (size 64) There is no binary code output differences from this change. Link: https://lore.kernel.org/r/20220901205729.2260982-1-keescook@chromium.org Cc: Bradley Grove <linuxdrivers@attotech.com> Cc: "James E.J. Bottomley" <jejb@linux.ibm.com> Cc: "Martin K. Petersen" <martin.petersen@oracle.com> Cc: linux-scsi@vger.kernel.org Reviewed-by: Gustavo A. R. Silva <gustavoars@kernel.org> Signed-off-by: Kees Cook <keescook@chromium.org> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
2021-06-02scsi: esas2r: Switch to flexible array memberKees Cook
In preparation for FORTIFY_SOURCE performing compile-time and run-time field bounds checking for memcpy(), avoid intentionally writing across neighboring array fields. Remove old-style 1-byte array in favor of a flexible array[1] to avoid future false-positive cross-field memcpy() warning in: esas2r_vda.c: memcpy(vi->cmd.gsv.version_info, esas2r_vdaioctl_versions, ...) The change in struct size doesn't change other structure sizes (it is already maxed out to 256 bytes, for example here: union { struct atto_ioctl_vda_scsi_cmd scsi; struct atto_ioctl_vda_flash_cmd flash; struct atto_ioctl_vda_diag_cmd diag; struct atto_ioctl_vda_cli_cmd cli; struct atto_ioctl_vda_smp_cmd smp; struct atto_ioctl_vda_cfg_cmd cfg; struct atto_ioctl_vda_mgt_cmd mgt; struct atto_ioctl_vda_gsv_cmd gsv; u8 cmd_info[256]; } cmd; No sizes are calculated using the enclosing structure, so no other updates are needed. Link: https://lore.kernel.org/r/20210528181337.792268-3-keescook@chromium.org Reviewed-by: Gustavo A. R. Silva <gustavoars@kernel.org> Signed-off-by: Kees Cook <keescook@chromium.org> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
2013-09-03[SCSI] esas2r: ATTO Technology ExpressSAS 6G SAS/SATA RAID Adapter DriverBradley Grove
This is a new driver for ATTO Technology's ExpressSAS series of hardware RAID adapters. It supports the following adapters: - ExpressSAS R60F - ExpressSAS R680 - ExpressSAS R608 - ExpressSAS R644 Signed-off-by: Bradley Grove <bgrove@attotech.com> Signed-off-by: James Bottomley <JBottomley@Parallels.com>