summaryrefslogtreecommitdiff
diff options
context:
space:
mode:
authorChen-Yu Tsai <wens@csie.org>2025-07-02 00:36:52 +0800
committerLee Jones <lee@kernel.org>2025-07-24 11:27:19 +0100
commit1421c3aff49914d83b83be2f9e17007ba4397dc9 (patch)
tree0acad5458519b00f6ca8e4624359bc20f9d2eea2
parent147dea662eaaf2da54bc2ec4d65053325036d734 (diff)
mfd: axp20x: Set explicit ID for regulator cell if no IRQ line is present
Originally an explicit ID for the AXP313/AXP323 regulator was set to avoid a conflict with the primary AXP717 PMIC on Allwinner A523 family boards. This didn't entirely work since on some or all of these boards, the interrupt line on this secondary PMIC was left unconnected, and thus the driver would fall back to the generic "no interrupt; only regulators" case, which didn't have the explicit ID set, thus undoing the intended fix. Also set an explicit ID for the regulator cell in the no IRQ generic fall back case. This fixes the conflict for the AXP717 + AXP313/AXP323 case. For the actual single PMIC with no IRQ connected case, the ID does not affect functionality, only the device naming of the regulator cell, and by extension the name and path under sysfs. Fixes: 249abf9b1e25 ("mfd: axp20x: Set explicit ID for AXP313 regulator") Signed-off-by: Chen-Yu Tsai <wens@csie.org> Link: https://lore.kernel.org/r/20250701163652.252010-1-wens@kernel.org Signed-off-by: Lee Jones <lee@kernel.org>
-rw-r--r--drivers/mfd/axp20x.c5
1 files changed, 2 insertions, 3 deletions
diff --git a/drivers/mfd/axp20x.c b/drivers/mfd/axp20x.c
index 25c639b348cd..c5f0ebae327f 100644
--- a/drivers/mfd/axp20x.c
+++ b/drivers/mfd/axp20x.c
@@ -1231,9 +1231,8 @@ static const struct mfd_cell axp15060_cells[] = {
/* For boards that don't have IRQ line connected to SOC. */
static const struct mfd_cell axp_regulator_only_cells[] = {
- {
- .name = "axp20x-regulator",
- },
+ /* PMIC without IRQ line may be secondary PMIC */
+ MFD_CELL_BASIC("axp20x-regulator", NULL, NULL, 0, 1),
};
static int axp20x_power_off(struct sys_off_data *data)