power: supply: bq24190: Fix BQ24296 Vbus regulator support
There are 2 issues with bq24296_set_otg_vbus(): 1. When writing the OTG_CONFIG bit it uses POC_CHG_CONFIG_SHIFT which should be POC_OTG_CONFIG_SHIFT. 2. When turning the regulator off it never turns charging back on. Note this must be done through bq24190_charger_set_charge_type(), to ensure that the charge_type property value of none/trickle/fast is honored. Resolve both issues to fix BQ24296 Vbus regulator support not working. Fixes: b150a703b56f ("power: supply: bq24190_charger: Add support for BQ24296") Signed-off-by: Hans de Goede <hdegoede@redhat.com> Link: https://lore.kernel.org/r/20241116203648.169100-2-hdegoede@redhat.com Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
-rw-r--r--drivers/power/supply/bq24190_charger.c12
1 files changed, 9 insertions, 3 deletions
diff --git a/drivers/power/supply/bq24190_charger.c b/drivers/power/supply/bq24190_charger.c
index 2b393eb5c282..c47f32f152e6 100644
--- a/drivers/power/supply/bq24190_charger.c
+++ b/drivers/power/supply/bq24190_charger.c
@@ -567,6 +567,7 @@ static int bq24190_set_otg_vbus(struct bq24190_dev_info *bdi, bool enable)
static int bq24296_set_otg_vbus(struct bq24190_dev_info *bdi, bool enable)
{
+ union power_supply_propval val = { .intval = bdi->charge_type };
int ret;
ret = pm_runtime_resume_and_get(bdi->dev);
@@ -587,13 +588,18 @@ static int bq24296_set_otg_vbus(struct bq24190_dev_info *bdi, bool enable)
ret = bq24190_write_mask(bdi, BQ24190_REG_POC,
BQ24296_REG_POC_OTG_CONFIG_MASK,
- BQ24296_REG_POC_CHG_CONFIG_SHIFT,
+ BQ24296_REG_POC_OTG_CONFIG_SHIFT,
BQ24296_REG_POC_OTG_CONFIG_OTG);
- } else
+ } else {
ret = bq24190_write_mask(bdi, BQ24190_REG_POC,
BQ24296_REG_POC_OTG_CONFIG_MASK,
- BQ24296_REG_POC_CHG_CONFIG_SHIFT,
+ BQ24296_REG_POC_OTG_CONFIG_SHIFT,
BQ24296_REG_POC_OTG_CONFIG_DISABLE);
+ if (ret < 0)
+ goto out;
+
+ ret = bq24190_charger_set_charge_type(bdi, &val);
+ }
out:
pm_runtime_mark_last_busy(bdi->dev);