diff options
author | Ian Ray <ian.ray@ge.com> | 2023-09-21 13:47:50 +0300 |
---|---|---|
committer | Robert Foss <rfoss@kernel.org> | 2023-10-13 16:28:58 +0200 |
commit | e0eb7db49764306a969183e0ed16659b24be89c1 (patch) | |
tree | 707151a161520ae730441d5166d1920f0438ae2c /drivers/gpu/drm/bridge | |
parent | a18f17248944fb068283c4bf819758fb0c9c987b (diff) |
drm/bridge: megachips-stdpxxxx-ge-b850v3-fw: switch to drm_do_get_edid()
Migrate away from custom EDID parsing and validity checks.
Note: This is a follow-up to the original RFC by Jani [1]. The first
submission in this series should have been marked v2.
[1] https://patchwork.freedesktop.org/patch/msgid/20230901102400.552254-1-jani.nikula@intel.com
Co-developed-by: Jani Nikula <jani.nikula@intel.com>
Signed-off-by: Jani Nikula <jani.nikula@intel.com>
Signed-off-by: Ian Ray <ian.ray@ge.com>
Reviewed-by: Robert Foss <rfoss@kernel.org>
Signed-off-by: Robert Foss <rfoss@kernel.org>
Link: https://patchwork.freedesktop.org/patch/msgid/20230921104751.56544-1-ian.ray@ge.com
Diffstat (limited to 'drivers/gpu/drm/bridge')
-rw-r--r-- | drivers/gpu/drm/bridge/megachips-stdpxxxx-ge-b850v3-fw.c | 57 |
1 files changed, 9 insertions, 48 deletions
diff --git a/drivers/gpu/drm/bridge/megachips-stdpxxxx-ge-b850v3-fw.c b/drivers/gpu/drm/bridge/megachips-stdpxxxx-ge-b850v3-fw.c index 460db3c8a08c..e93083bbec9d 100644 --- a/drivers/gpu/drm/bridge/megachips-stdpxxxx-ge-b850v3-fw.c +++ b/drivers/gpu/drm/bridge/megachips-stdpxxxx-ge-b850v3-fw.c @@ -65,12 +65,11 @@ struct ge_b850v3_lvds { static struct ge_b850v3_lvds *ge_b850v3_lvds_ptr; -static u8 *stdp2690_get_edid(struct i2c_client *client) +static int stdp2690_read_block(void *context, u8 *buf, unsigned int block, size_t len) { + struct i2c_client *client = context; struct i2c_adapter *adapter = client->adapter; - unsigned char start = 0x00; - unsigned int total_size; - u8 *block = kmalloc(EDID_LENGTH, GFP_KERNEL); + unsigned char start = block * EDID_LENGTH; struct i2c_msg msgs[] = { { @@ -81,53 +80,15 @@ static u8 *stdp2690_get_edid(struct i2c_client *client) }, { .addr = client->addr, .flags = I2C_M_RD, - .len = EDID_LENGTH, - .buf = block, + .len = len, + .buf = buf, } }; - if (!block) - return NULL; + if (i2c_transfer(adapter, msgs, 2) != 2) + return -1; - if (i2c_transfer(adapter, msgs, 2) != 2) { - DRM_ERROR("Unable to read EDID.\n"); - goto err; - } - - if (!drm_edid_block_valid(block, 0, false, NULL)) { - DRM_ERROR("Invalid EDID data\n"); - goto err; - } - - total_size = (block[EDID_EXT_BLOCK_CNT] + 1) * EDID_LENGTH; - if (total_size > EDID_LENGTH) { - kfree(block); - block = kmalloc(total_size, GFP_KERNEL); - if (!block) - return NULL; - - /* Yes, read the entire buffer, and do not skip the first - * EDID_LENGTH bytes. - */ - start = 0x00; - msgs[1].len = total_size; - msgs[1].buf = block; - - if (i2c_transfer(adapter, msgs, 2) != 2) { - DRM_ERROR("Unable to read EDID extension blocks.\n"); - goto err; - } - if (!drm_edid_block_valid(block, 1, false, NULL)) { - DRM_ERROR("Invalid EDID data\n"); - goto err; - } - } - - return block; - -err: - kfree(block); - return NULL; + return 0; } static struct edid *ge_b850v3_lvds_get_edid(struct drm_bridge *bridge, @@ -137,7 +98,7 @@ static struct edid *ge_b850v3_lvds_get_edid(struct drm_bridge *bridge, client = ge_b850v3_lvds_ptr->stdp2690_i2c; - return (struct edid *)stdp2690_get_edid(client); + return drm_do_get_edid(connector, stdp2690_read_block, client); } static int ge_b850v3_lvds_get_modes(struct drm_connector *connector) |