summaryrefslogtreecommitdiff
path: root/drivers/hwmon/hwmon.c
diff options
context:
space:
mode:
authorJavier Carrasco <javier.carrasco.cruz@gmail.com>2024-01-30 22:06:45 +0100
committerGuenter Roeck <linux@roeck-us.net>2024-02-25 12:37:37 -0800
commit5f85c4d10ef46a5f457a9d337159ff620a0a2191 (patch)
treef682bee51310c919cd948cf1feef9421760fdc1c /drivers/hwmon/hwmon.c
parentcc804e48fef1535150f7b300b81990230b8a10f0 (diff)
hwmon: (core) Add support for humidity min/max alarm
Add min_alarm and max_alarm attributes for humidityX to support devices that can generate these alarms. Such attributes already exist for other magnitudes such as tempX. Tested with a ChipCap 2 temperature-humidity sensor. Signed-off-by: Javier Carrasco <javier.carrasco.cruz@gmail.com> Link: https://lore.kernel.org/r/20240130-topic-chipcap2-v6-2-260bea05cf9b@gmail.com Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Diffstat (limited to 'drivers/hwmon/hwmon.c')
-rw-r--r--drivers/hwmon/hwmon.c2
1 files changed, 2 insertions, 0 deletions
diff --git a/drivers/hwmon/hwmon.c b/drivers/hwmon/hwmon.c
index 18705049ad61..3b259c425ab7 100644
--- a/drivers/hwmon/hwmon.c
+++ b/drivers/hwmon/hwmon.c
@@ -587,6 +587,8 @@ static const char * const hwmon_humidity_attr_templates[] = {
[hwmon_humidity_fault] = "humidity%d_fault",
[hwmon_humidity_rated_min] = "humidity%d_rated_min",
[hwmon_humidity_rated_max] = "humidity%d_rated_max",
+ [hwmon_humidity_min_alarm] = "humidity%d_min_alarm",
+ [hwmon_humidity_max_alarm] = "humidity%d_max_alarm",
};
static const char * const hwmon_fan_attr_templates[] = {