diff options
author | Crag Wang <crag0715@gmail.com> | 2020-07-30 11:26:09 +0800 |
---|---|---|
committer | Sebastian Reichel <sre@kernel.org> | 2020-07-31 14:33:56 +0200 |
commit | 46cbd0b05799e8234b719d18f3a4b27679c4c92e (patch) | |
tree | 52a1a6ae1c4cc2443a046ecdeb1c2bac72017720 /drivers/power/supply/power_supply_sysfs.c | |
parent | 707d678a5c7c5e80d1caac6c6b021171f5ecde58 (diff) |
power: supply: wilco_ec: Add long life charging mode
This is a long life mode set in the factory for extended warranty
battery, the power charging rate is customized so that battery at
work last longer.
Presently switching to a different battery charging mode is through
EC PID 0x0710 to configure the battery firmware, this operation will
be blocked by EC with failure code 0x01 when PLL mode is already
in use.
Signed-off-by: Crag Wang <crag.wang@dell.com>
Reviewed-by: Mario Limonciello <mario.limonciello@dell.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
Diffstat (limited to 'drivers/power/supply/power_supply_sysfs.c')
-rw-r--r-- | drivers/power/supply/power_supply_sysfs.c | 1 |
1 files changed, 1 insertions, 0 deletions
diff --git a/drivers/power/supply/power_supply_sysfs.c b/drivers/power/supply/power_supply_sysfs.c index b903cb4dca2b..3d383086018c 100644 --- a/drivers/power/supply/power_supply_sysfs.c +++ b/drivers/power/supply/power_supply_sysfs.c @@ -87,6 +87,7 @@ static const char * const POWER_SUPPLY_CHARGE_TYPE_TEXT[] = { [POWER_SUPPLY_CHARGE_TYPE_STANDARD] = "Standard", [POWER_SUPPLY_CHARGE_TYPE_ADAPTIVE] = "Adaptive", [POWER_SUPPLY_CHARGE_TYPE_CUSTOM] = "Custom", + [POWER_SUPPLY_CHARGE_TYPE_LONGLIFE] = "Long Life", }; static const char * const POWER_SUPPLY_HEALTH_TEXT[] = { |