summaryrefslogtreecommitdiff
path: root/drivers/scsi/megaraid
diff options
context:
space:
mode:
authorGustavo A. R. Silva <gustavo@embeddedor.com>2019-06-07 13:40:53 -0500
committerMartin K. Petersen <martin.petersen@oracle.com>2019-06-20 15:37:03 -0400
commite58ed5002f17ed027272088fa0d3e57fa81bd8d4 (patch)
tree94ef1c2c9d0524504134a9bd601b91d21ea485d1 /drivers/scsi/megaraid
parent7c1f3e3447a13a91e95fff6bac7312858c90b0cf (diff)
scsi: megaraid_sas: Use struct_size() helper
One of the more common cases of allocation size calculations is finding the size of a structure that has a zero-sized array at the end, along with memory for some number of elements for that array. For example: struct MR_PD_CFG_SEQ_NUM_SYNC { ... struct MR_PD_CFG_SEQ seq[1]; } __packed; Make use of the struct_size() helper instead of an open-coded version in order to avoid any potential type mistakes. So, replace the following form: sizeof(struct MR_PD_CFG_SEQ_NUM_SYNC) + (sizeof(struct MR_PD_CFG_SEQ) * (MAX_PHYSICAL_DEVICES - 1)) with: struct_size(pd_sync, seq, MAX_PHYSICAL_DEVICES - 1) This code was detected with the help of Coccinelle. Signed-off-by: Gustavo A. R. Silva <gustavo@embeddedor.com> Acked-by: Sumit Saxena <sumit.saxena@broadcom.com> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
Diffstat (limited to 'drivers/scsi/megaraid')
-rw-r--r--drivers/scsi/megaraid/megaraid_sas_fusion.c6
1 files changed, 2 insertions, 4 deletions
diff --git a/drivers/scsi/megaraid/megaraid_sas_fusion.c b/drivers/scsi/megaraid/megaraid_sas_fusion.c
index 2edb08247efa..8a7ac5c09c53 100644
--- a/drivers/scsi/megaraid/megaraid_sas_fusion.c
+++ b/drivers/scsi/megaraid/megaraid_sas_fusion.c
@@ -1203,7 +1203,7 @@ fail_fw_init:
int
megasas_sync_pd_seq_num(struct megasas_instance *instance, bool pend) {
int ret = 0;
- u32 pd_seq_map_sz;
+ size_t pd_seq_map_sz;
struct megasas_cmd *cmd;
struct megasas_dcmd_frame *dcmd;
struct fusion_context *fusion = instance->ctrl_context;
@@ -1212,9 +1212,7 @@ megasas_sync_pd_seq_num(struct megasas_instance *instance, bool pend) {
pd_sync = (void *)fusion->pd_seq_sync[(instance->pd_seq_map_id & 1)];
pd_seq_h = fusion->pd_seq_phys[(instance->pd_seq_map_id & 1)];
- pd_seq_map_sz = sizeof(struct MR_PD_CFG_SEQ_NUM_SYNC) +
- (sizeof(struct MR_PD_CFG_SEQ) *
- (MAX_PHYSICAL_DEVICES - 1));
+ pd_seq_map_sz = struct_size(pd_sync, seq, MAX_PHYSICAL_DEVICES - 1);
cmd = megasas_get_cmd(instance);
if (!cmd) {