summaryrefslogtreecommitdiff
diff options
context:
space:
mode:
-rw-r--r--Documentation/devicetree/bindings/regulator/regulator.yaml8
1 files changed, 8 insertions, 0 deletions
diff --git a/Documentation/devicetree/bindings/regulator/regulator.yaml b/Documentation/devicetree/bindings/regulator/regulator.yaml
index 5b8d55f7c43b..1ef380d1515e 100644
--- a/Documentation/devicetree/bindings/regulator/regulator.yaml
+++ b/Documentation/devicetree/bindings/regulator/regulator.yaml
@@ -186,6 +186,14 @@ properties:
be enabled but limit setting can be omitted. Limit is given as microvolt
offset from voltage set to regulator.
+ regulator-uv-less-critical-window-ms:
+ description: Specifies the time window (in milliseconds) following a
+ critical under-voltage event during which the system can continue to
+ operate safely while performing less critical operations. This property
+ provides a defined duration before a more severe reaction to the
+ under-voltage event is needed, allowing for certain non-urgent actions to
+ be carried out in preparation for potential power loss.
+
regulator-temp-protection-kelvin:
description: Set over temperature protection limit. This is a limit where
hardware performs emergency shutdown. Zero can be passed to disable