diff options
Diffstat (limited to 'arch/powerpc/kvm/Kconfig')
| -rw-r--r-- | arch/powerpc/kvm/Kconfig | 29 |
1 files changed, 18 insertions, 11 deletions
diff --git a/arch/powerpc/kvm/Kconfig b/arch/powerpc/kvm/Kconfig index 902611954200..c9a2d50ff1b0 100644 --- a/arch/powerpc/kvm/Kconfig +++ b/arch/powerpc/kvm/Kconfig @@ -19,13 +19,9 @@ if VIRTUALIZATION config KVM bool - select PREEMPT_NOTIFIERS - select HAVE_KVM_EVENTFD - select HAVE_KVM_VCPU_ASYNC_IOCTL + select KVM_COMMON select KVM_VFIO - select IRQ_BYPASS_MANAGER select HAVE_KVM_IRQ_BYPASS - select INTERVAL_TREE config KVM_BOOK3S_HANDLER bool @@ -42,7 +38,7 @@ config KVM_BOOK3S_64_HANDLER config KVM_BOOK3S_PR_POSSIBLE bool select KVM_MMIO - select MMU_NOTIFIER + select KVM_GENERIC_MMU_NOTIFIER config KVM_BOOK3S_HV_POSSIBLE bool @@ -85,7 +81,8 @@ config KVM_BOOK3S_64_HV tristate "KVM for POWER7 and later using hypervisor mode in host" depends on KVM_BOOK3S_64 && PPC_POWERNV select KVM_BOOK3S_HV_POSSIBLE - select MMU_NOTIFIER + select KVM_GENERIC_MMU_NOTIFIER + select KVM_BOOK3S_HV_PMU select CMA help Support running unmodified book3s_64 guest kernels in @@ -174,6 +171,18 @@ config KVM_BOOK3S_HV_NESTED_PMU_WORKAROUND those buggy L1s which saves the L2 state, at the cost of performance in all nested-capable guest entry/exit. +config KVM_BOOK3S_HV_PMU + tristate "Hypervisor Perf events for KVM Book3s-HV" + depends on KVM_BOOK3S_64_HV + help + Enable Book3s-HV Hypervisor Perf events PMU named 'kvm-hv'. These + Perf events give an overview of hypervisor performance overall + instead of a specific guests. Currently the PMU reports + L0-Hypervisor stats on a kvm-hv enabled PSeries LPAR like: + * Total/Used Guest-Heap + * Total/Used Guest Page-table Memory + * Total amount of Guest Page-table Memory reclaimed + config KVM_BOOKE_HV bool @@ -194,7 +203,7 @@ config KVM_E500V2 depends on !CONTEXT_TRACKING_USER select KVM select KVM_MMIO - select MMU_NOTIFIER + select KVM_GENERIC_MMU_NOTIFIER help Support running unmodified E500 guest kernels in virtual machines on E500v2 host processors. @@ -211,7 +220,7 @@ config KVM_E500MC select KVM select KVM_MMIO select KVM_BOOKE_HV - select MMU_NOTIFIER + select KVM_GENERIC_MMU_NOTIFIER help Support running unmodified E500MC/E5500/E6500 guest kernels in virtual machines on E500MC/E5500/E6500 host processors. @@ -225,7 +234,6 @@ config KVM_MPIC bool "KVM in-kernel MPIC emulation" depends on KVM && PPC_E500 select HAVE_KVM_IRQCHIP - select HAVE_KVM_IRQFD select HAVE_KVM_IRQ_ROUTING select HAVE_KVM_MSI help @@ -238,7 +246,6 @@ config KVM_XICS bool "KVM in-kernel XICS emulation" depends on KVM_BOOK3S_64 && !KVM_MPIC select HAVE_KVM_IRQCHIP - select HAVE_KVM_IRQFD default y help Include support for the XICS (eXternal Interrupt Controller |
