diff options
Diffstat (limited to 'drivers/acpi/processor_thermal.c')
| -rw-r--r-- | drivers/acpi/processor_thermal.c | 166 |
1 files changed, 131 insertions, 35 deletions
diff --git a/drivers/acpi/processor_thermal.c b/drivers/acpi/processor_thermal.c index 41feb88ee92d..c7b1dc5687ec 100644 --- a/drivers/acpi/processor_thermal.c +++ b/drivers/acpi/processor_thermal.c @@ -17,11 +17,7 @@ #include <acpi/processor.h> #include <linux/uaccess.h> -#define PREFIX "ACPI: " - -#define ACPI_PROCESSOR_CLASS "processor" -#define _COMPONENT ACPI_PROCESSOR_COMPONENT -ACPI_MODULE_NAME("processor_thermal"); +#include "internal.h" #ifdef CONFIG_CPU_FREQ @@ -32,12 +28,21 @@ ACPI_MODULE_NAME("processor_thermal"); */ #define CPUFREQ_THERMAL_MIN_STEP 0 -#define CPUFREQ_THERMAL_MAX_STEP 3 -static DEFINE_PER_CPU(unsigned int, cpufreq_thermal_reduction_pctg); +static int cpufreq_thermal_max_step __read_mostly = 3; + +/* + * Minimum throttle percentage for processor_thermal cooling device. + * The processor_thermal driver uses it to calculate the percentage amount by + * which cpu frequency must be reduced for each cooling state. This is also used + * to calculate the maximum number of throttling steps or cooling states. + */ +static int cpufreq_thermal_reduction_pctg __read_mostly = 20; + +static DEFINE_PER_CPU(unsigned int, cpufreq_thermal_reduction_step); -#define reduction_pctg(cpu) \ - per_cpu(cpufreq_thermal_reduction_pctg, phys_package_first_cpu(cpu)) +#define reduction_step(cpu) \ + per_cpu(cpufreq_thermal_reduction_step, phys_package_first_cpu(cpu)) /* * Emulate "per package data" using per cpu data (which should really be @@ -57,12 +62,14 @@ static int phys_package_first_cpu(int cpu) return 0; } -static int cpu_has_cpufreq(unsigned int cpu) +static bool cpu_has_cpufreq(unsigned int cpu) { - struct cpufreq_policy policy; - if (!acpi_processor_cpufreq_init || cpufreq_get_policy(&policy, cpu)) + if (!acpi_processor_cpufreq_init) return 0; - return 1; + + struct cpufreq_policy *policy __free(put_cpufreq_policy) = cpufreq_cpu_get(cpu); + + return policy != NULL; } static int cpufreq_get_max_state(unsigned int cpu) @@ -70,7 +77,7 @@ static int cpufreq_get_max_state(unsigned int cpu) if (!cpu_has_cpufreq(cpu)) return 0; - return CPUFREQ_THERMAL_MAX_STEP; + return cpufreq_thermal_max_step; } static int cpufreq_get_cur_state(unsigned int cpu) @@ -78,20 +85,39 @@ static int cpufreq_get_cur_state(unsigned int cpu) if (!cpu_has_cpufreq(cpu)) return 0; - return reduction_pctg(cpu); + return reduction_step(cpu); +} + +static bool cpufreq_update_thermal_limit(unsigned int cpu, struct acpi_processor *pr) +{ + unsigned long max_freq; + int ret; + + struct cpufreq_policy *policy __free(put_cpufreq_policy) = cpufreq_cpu_get(cpu); + if (!policy) + return false; + + max_freq = (policy->cpuinfo.max_freq * + (100 - reduction_step(cpu) * cpufreq_thermal_reduction_pctg)) / 100; + + ret = freq_qos_update_request(&pr->thermal_req, max_freq); + if (ret < 0) { + pr_warn("Failed to update thermal freq constraint: CPU%d (%d)\n", + pr->id, ret); + } + + return true; } static int cpufreq_set_cur_state(unsigned int cpu, int state) { - struct cpufreq_policy *policy; struct acpi_processor *pr; - unsigned long max_freq; - int i, ret; + int i; if (!cpu_has_cpufreq(cpu)) return 0; - reduction_pctg(cpu) = state; + reduction_step(cpu) = state; /* * Update all the CPUs in the same package because they all @@ -108,27 +134,35 @@ static int cpufreq_set_cur_state(unsigned int cpu, int state) if (unlikely(!freq_qos_request_active(&pr->thermal_req))) continue; - policy = cpufreq_cpu_get(i); - if (!policy) + if (!cpufreq_update_thermal_limit(i, pr)) return -EINVAL; + } + return 0; +} - max_freq = (policy->cpuinfo.max_freq * (100 - reduction_pctg(i) * 20)) / 100; +static void acpi_thermal_cpufreq_config(void) +{ + int cpufreq_pctg = acpi_arch_thermal_cpufreq_pctg(); - cpufreq_cpu_put(policy); + if (!cpufreq_pctg) + return; - ret = freq_qos_update_request(&pr->thermal_req, max_freq); - if (ret < 0) { - pr_warn("Failed to update thermal freq constraint: CPU%d (%d)\n", - pr->id, ret); - } - } - return 0; + cpufreq_thermal_reduction_pctg = cpufreq_pctg; + + /* + * Derive the MAX_STEP from minimum throttle percentage so that the reduction + * percentage doesn't end up becoming negative. Also, cap the MAX_STEP so that + * the CPU performance doesn't become 0. + */ + cpufreq_thermal_max_step = (100 / cpufreq_pctg) - 2; } void acpi_thermal_cpufreq_init(struct cpufreq_policy *policy) { unsigned int cpu; + acpi_thermal_cpufreq_config(); + for_each_cpu(cpu, policy->related_cpus) { struct acpi_processor *pr = per_cpu(processors, cpu); int ret; @@ -139,9 +173,13 @@ void acpi_thermal_cpufreq_init(struct cpufreq_policy *policy) ret = freq_qos_add_request(&policy->constraints, &pr->thermal_req, FREQ_QOS_MAX, INT_MAX); - if (ret < 0) + if (ret < 0) { pr_err("Failed to add freq constraint for CPU%d (%d)\n", cpu, ret); + continue; + } + + thermal_cooling_device_update(pr->cdev); } } @@ -150,10 +188,14 @@ void acpi_thermal_cpufreq_exit(struct cpufreq_policy *policy) unsigned int cpu; for_each_cpu(cpu, policy->related_cpus) { - struct acpi_processor *pr = per_cpu(processors, policy->cpu); + struct acpi_processor *pr = per_cpu(processors, cpu); + + if (!pr) + continue; - if (pr) - freq_qos_remove_request(&pr->thermal_req); + freq_qos_remove_request(&pr->thermal_req); + + thermal_cooling_device_update(pr->cdev); } } #else /* ! CONFIG_CPU_FREQ */ @@ -181,7 +223,7 @@ static int acpi_processor_max_state(struct acpi_processor *pr) /* * There exists four states according to - * cpufreq_thermal_reduction_pctg. 0, 1, 2, 3 + * cpufreq_thermal_reduction_step. 0, 1, 2, 3 */ max_state += cpufreq_get_max_state(pr->id); if (pr->flags.throttling) @@ -265,3 +307,57 @@ const struct thermal_cooling_device_ops processor_cooling_ops = { .get_cur_state = processor_get_cur_state, .set_cur_state = processor_set_cur_state, }; + +int acpi_processor_thermal_init(struct acpi_processor *pr, + struct acpi_device *device) +{ + int result = 0; + + pr->cdev = thermal_cooling_device_register("Processor", device, + &processor_cooling_ops); + if (IS_ERR(pr->cdev)) { + result = PTR_ERR(pr->cdev); + return result; + } + + dev_dbg(&device->dev, "registered as cooling_device%d\n", + pr->cdev->id); + + result = sysfs_create_link(&device->dev.kobj, + &pr->cdev->device.kobj, + "thermal_cooling"); + if (result) { + dev_err(&device->dev, + "Failed to create sysfs link 'thermal_cooling'\n"); + goto err_thermal_unregister; + } + + result = sysfs_create_link(&pr->cdev->device.kobj, + &device->dev.kobj, + "device"); + if (result) { + dev_err(&pr->cdev->device, + "Failed to create sysfs link 'device'\n"); + goto err_remove_sysfs_thermal; + } + + return 0; + +err_remove_sysfs_thermal: + sysfs_remove_link(&device->dev.kobj, "thermal_cooling"); +err_thermal_unregister: + thermal_cooling_device_unregister(pr->cdev); + + return result; +} + +void acpi_processor_thermal_exit(struct acpi_processor *pr, + struct acpi_device *device) +{ + if (pr->cdev) { + sysfs_remove_link(&device->dev.kobj, "thermal_cooling"); + sysfs_remove_link(&pr->cdev->device.kobj, "device"); + thermal_cooling_device_unregister(pr->cdev); + pr->cdev = NULL; + } +} |
