summaryrefslogtreecommitdiff
path: root/drivers/net/dsa/microchip/lan937x_main.c
diff options
context:
space:
mode:
Diffstat (limited to 'drivers/net/dsa/microchip/lan937x_main.c')
-rw-r--r--drivers/net/dsa/microchip/lan937x_main.c62
1 files changed, 59 insertions, 3 deletions
diff --git a/drivers/net/dsa/microchip/lan937x_main.c b/drivers/net/dsa/microchip/lan937x_main.c
index b7652efd632e..b1ae3b9de3d1 100644
--- a/drivers/net/dsa/microchip/lan937x_main.c
+++ b/drivers/net/dsa/microchip/lan937x_main.c
@@ -1,6 +1,6 @@
// SPDX-License-Identifier: GPL-2.0
/* Microchip LAN937X switch driver main logic
- * Copyright (C) 2019-2022 Microchip Technology Inc.
+ * Copyright (C) 2019-2024 Microchip Technology Inc.
*/
#include <linux/kernel.h>
#include <linux/module.h>
@@ -461,10 +461,66 @@ int lan937x_change_mtu(struct ksz_device *dev, int port, int new_mtu)
int lan937x_set_ageing_time(struct ksz_device *dev, unsigned int msecs)
{
- u32 secs = msecs / 1000;
- u32 value;
+ u8 data, mult, value8;
+ bool in_msec = false;
+ u32 max_val, value;
+ u32 secs = msecs;
int ret;
+#define MAX_TIMER_VAL ((1 << 20) - 1)
+
+ /* The aging timer comprises a 3-bit multiplier and a 20-bit second
+ * value. Either of them cannot be zero. The maximum timer is then
+ * 7 * 1048575 = 7340025 seconds. As this value is too large for
+ * practical use it can be interpreted as microseconds, making the
+ * maximum timer 7340 seconds with finer control. This allows for
+ * maximum 122 minutes compared to 29 minutes in KSZ9477 switch.
+ */
+ if (msecs % 1000)
+ in_msec = true;
+ else
+ secs /= 1000;
+ if (!secs)
+ secs = 1;
+
+ /* Return error if too large. */
+ else if (secs > 7 * MAX_TIMER_VAL)
+ return -EINVAL;
+
+ /* Configure how to interpret the number value. */
+ ret = ksz_rmw8(dev, REG_SW_LUE_CTRL_2, SW_AGE_CNT_IN_MICROSEC,
+ in_msec ? SW_AGE_CNT_IN_MICROSEC : 0);
+ if (ret < 0)
+ return ret;
+
+ ret = ksz_read8(dev, REG_SW_LUE_CTRL_0, &value8);
+ if (ret < 0)
+ return ret;
+
+ /* Check whether there is need to update the multiplier. */
+ mult = FIELD_GET(SW_AGE_CNT_M, value8);
+ max_val = MAX_TIMER_VAL;
+ if (mult > 0) {
+ /* Try to use the same multiplier already in the register as
+ * the hardware default uses multiplier 4 and 75 seconds for
+ * 300 seconds.
+ */
+ max_val = DIV_ROUND_UP(secs, mult);
+ if (max_val > MAX_TIMER_VAL || max_val * mult != secs)
+ max_val = MAX_TIMER_VAL;
+ }
+
+ data = DIV_ROUND_UP(secs, max_val);
+ if (mult != data) {
+ value8 &= ~SW_AGE_CNT_M;
+ value8 |= FIELD_PREP(SW_AGE_CNT_M, data);
+ ret = ksz_write8(dev, REG_SW_LUE_CTRL_0, value8);
+ if (ret < 0)
+ return ret;
+ }
+
+ secs = DIV_ROUND_UP(secs, data);
+
value = FIELD_GET(SW_AGE_PERIOD_7_0_M, secs);
ret = ksz_write8(dev, REG_SW_AGE_PERIOD__1, value);