diff --git a/drivers/thermal/cpufreq_cooling.c b/drivers/thermal/cpufreq_cooling.c
index cb75f1365615..b76293cc989c 100644
--- a/drivers/thermal/cpufreq_cooling.c
+++ b/drivers/thermal/cpufreq_cooling.c
@@ -60,6 +60,7 @@ struct time_in_idle {
* @cdev: thermal_cooling_device pointer to keep track of the
* registered cooling device.
* @policy: cpufreq policy.
+ * @cooling_ops: cpufreq callbacks to thermal cooling device ops
* @idle_time: idle time stats
* @qos_req: PM QoS contraint to apply
*
@@ -72,6 +73,7 @@ struct cpufreq_cooling_device {
unsigned int max_level;
struct em_perf_domain *em;
struct cpufreq_policy *policy;
+ struct thermal_cooling_device_ops cooling_ops;
#ifndef CONFIG_SMP
struct time_in_idle *idle_time;
#endif
@@ -211,7 +213,7 @@ static u32 get_dynamic_power(struct cpufreq_cooling_device *cpufreq_cdev,
* complex code may be needed if experiments show that it's not
* accurate enough.
*
- * Return: 0 on success, -E* if getting the static power failed.
+ * Return: 0 on success, this function doesn't fail.
*/
static int cpufreq_get_requested_power(struct thermal_cooling_device *cdev,
u32 *power)
@@ -221,16 +223,9 @@ static int cpufreq_get_requested_power(struct thermal_cooling_device *cdev,
u32 total_load = 0;
struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata;
struct cpufreq_policy *policy = cpufreq_cdev->policy;
- u32 *load_cpu = NULL;
freq = cpufreq_quick_get(policy->cpu);
- if (trace_thermal_power_cpu_get_power_enabled()) {
- u32 ncpus = cpumask_weight(policy->related_cpus);
-
- load_cpu = kcalloc(ncpus, sizeof(*load_cpu), GFP_KERNEL);
- }
-
for_each_cpu(cpu, policy->related_cpus) {
u32 load;
@@ -240,22 +235,13 @@ static int cpufreq_get_requested_power(struct thermal_cooling_device *cdev,
load = 0;
total_load += load;
- if (load_cpu)
- load_cpu[i] = load;
-
- i++;
}
cpufreq_cdev->last_load = total_load;
*power = get_dynamic_power(cpufreq_cdev, freq);
- if (load_cpu) {
- trace_thermal_power_cpu_get_power(policy->related_cpus, freq,
- load_cpu, i, *power);
-
- kfree(load_cpu);
- }
+ trace_thermal_power_cpu_get_power_simple(policy->cpu, *power);
return 0;
}
@@ -270,9 +256,8 @@ static int cpufreq_get_requested_power(struct thermal_cooling_device *cdev,
* milliwatts assuming 100% load. Store the calculated power in
* @power.
*
- * Return: 0 on success, -EINVAL if the cooling device state could not
- * be converted into a frequency or other -E* if there was an error
- * when calculating the static power.
+ * Return: 0 on success, -EINVAL if the cooling device state is bigger
+ * than maximum allowed.
*/
static int cpufreq_state2power(struct thermal_cooling_device *cdev,
unsigned long state, u32 *power)
@@ -302,15 +287,11 @@ static int cpufreq_state2power(struct thermal_cooling_device *cdev,
* Calculate a cooling device state for the cpus described by @cdev
* that would allow them to consume at most @power mW and store it in
* @state. Note that this calculation depends on external factors
- * such as the cpu load or the current static power. Calling this
- * function with the same power as input can yield different cooling
- * device states depending on those external factors.
- *
- * Return: 0 on success, -ENODEV if no cpus are online or -EINVAL if
- * the calculated frequency could not be converted to a valid state.
- * The latter should not happen unless the frequencies available to
- * cpufreq have changed since the initialization of the cpu cooling
- * device.
+ * such as the CPUs load. Calling this function with the same power
+ * as input can yield different cooling device states depending on those
+ * external factors.
+ *
+ * Return: 0 on success, this function doesn't fail.
*/
static int cpufreq_power2state(struct thermal_cooling_device *cdev,
u32 power, unsigned long *state)
@@ -422,7 +403,7 @@ static unsigned int get_state_freq(struct cpufreq_cooling_device *cpufreq_cdev,
* Callback for the thermal cooling device to return the cpufreq
* max cooling state.
*
- * Return: 0 on success, an error code otherwise.
+ * Return: 0 on success, this function doesn't fail.
*/
static int cpufreq_get_max_state(struct thermal_cooling_device *cdev,
unsigned long *state)
@@ -441,7 +422,7 @@ static int cpufreq_get_max_state(struct thermal_cooling_device *cdev,
* Callback for the thermal cooling device to return the cpufreq
* current cooling state.
*
- * Return: 0 on success, an error code otherwise.
+ * Return: 0 on success, this function doesn't fail.
*/
static int cpufreq_get_cur_state(struct thermal_cooling_device *cdev,
unsigned long *state)
@@ -492,14 +473,6 @@ static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev,
return ret;
}
-/* Bind cpufreq callbacks to thermal cooling device ops */
-
-static struct thermal_cooling_device_ops cpufreq_cooling_ops = {
- .get_max_state = cpufreq_get_max_state,
- .get_cur_state = cpufreq_get_cur_state,
- .set_cur_state = cpufreq_set_cur_state,
-};
-
/**
* __cpufreq_cooling_register - helper function to create cpufreq cooling device
* @np: a valid struct device_node to the cooling device device tree node
@@ -508,7 +481,7 @@ static struct thermal_cooling_device_ops cpufreq_cooling_ops = {
* @em: Energy Model of the cpufreq policy
*
* This interface function registers the cpufreq cooling device with the name
- * "thermal-cpufreq-%x". This api can support multiple instances of cpufreq
+ * "cpufreq-%s". This API can support multiple instances of cpufreq
* cooling devices. It also gives the opportunity to link the cooling device
* with a device tree node, in order to bind it via the thermal DT code.
*
@@ -561,7 +534,10 @@ __cpufreq_cooling_register(struct device_node *np,
/* max_level is an index, not a counter */
cpufreq_cdev->max_level = i - 1;
- cooling_ops = &cpufreq_cooling_ops;
+ cooling_ops = &cpufreq_cdev->cooling_ops;
+ cooling_ops->get_max_state = cpufreq_get_max_state;
+ cooling_ops->get_cur_state = cpufreq_get_cur_state;
+ cooling_ops->set_cur_state = cpufreq_set_cur_state;
#ifdef CONFIG_THERMAL_GOV_POWER_ALLOCATOR
if (em_is_sane(cpufreq_cdev, em)) {
@@ -616,8 +592,8 @@ free_cdev:
* @policy: cpufreq policy
*
* This interface function registers the cpufreq cooling device with the name
- * "thermal-cpufreq-%x". This api can support multiple instances of cpufreq
- * cooling devices.
+ * "cpufreq-%s". This API can support multiple instances of cpufreq cooling
+ * devices.
*
* Return: a valid struct thermal_cooling_device pointer on success,
* on failure, it returns a corresponding ERR_PTR().
@@ -634,17 +610,14 @@ EXPORT_SYMBOL_GPL(cpufreq_cooling_register);
* @policy: cpufreq policy
*
* This interface function registers the cpufreq cooling device with the name
- * "thermal-cpufreq-%x". This api can support multiple instances of cpufreq
- * cooling devices. Using this API, the cpufreq cooling device will be
- * linked to the device tree node provided.
+ * "cpufreq-%s". This API can support multiple instances of cpufreq cooling
+ * devices. Using this API, the cpufreq cooling device will be linked to the
+ * device tree node provided.
*
* Using this function, the cooling device will implement the power
- * extensions by using a simple cpu power model. The cpus must have
+ * extensions by using the Energy Model (if present). The cpus must have
* registered their OPPs using the OPP library.
*
- * It also takes into account, if property present in policy CPU node, the
- * static power consumed by the cpu.
- *
* Return: a valid struct thermal_cooling_device pointer on success,
* and NULL on failure.
*/
@@ -680,7 +653,7 @@ EXPORT_SYMBOL_GPL(of_cpufreq_cooling_register);
* cpufreq_cooling_unregister - function to remove cpufreq cooling device.
* @cdev: thermal cooling device pointer.
*
- * This interface function unregisters the "thermal-cpufreq-%x" cooling device.
+ * This interface function unregisters the "cpufreq-%x" cooling device.
*/
void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev)
{