summaryrefslogtreecommitdiff
path: root/drivers/gpu/drm/pl111/Makefile
AgeCommit message (Collapse)Author
2020-04-28drm: pl111: Move VExpress setup into versatile initRob Herring
Since the VExpress setup in pl111_vexpress.c is now just a single function call, let's move it into pl111_versatile.c and we can further simplify pl111_versatile_init() by moving the other pieces for VExpress into pl111_vexpress_clcd_init(). Cc: Eric Anholt <eric@anholt.net> Cc: dri-devel@lists.freedesktop.org Acked-by: Sam Ravnborg <sam@ravnborg.org> Reviewed-by: Linus Walleij <linus.walleij@linaro.org> Signed-off-by: Rob Herring <robh@kernel.org> Link: https://patchwork.freedesktop.org/patch/msgid/20200409013947.12667-4-robh@kernel.org
2018-07-01drm/pl111: Support Nomadik LCDC variantLinus Walleij
The Nomadik has a variant of the PL110 known as "Color LCD Controller" LCDC. This variant has the same bit ordering as the DRM subsystem (in difference from the other variants) and adds a few bits for the control of 5551, 565 etc in the control register. Notably it also adds a packed RGB888 24BPP mode. We add support by detecting this variant and also adding a small plug-in that will mux the LCDC out if the ASIC happens to be muxed to the other graphics controller (they are mutually exclusive). Reviewed-by: Eric Anholt <eric@anholt.net> Signed-off-by: Linus Walleij <linus.walleij@linaro.org> Link: https://patchwork.freedesktop.org/patch/msgid/20180621184450.25377-1-linus.walleij@linaro.org
2018-05-02drm/pl111: Support the Versatile ExpressLinus Walleij
The Versatile Express uses a special configuration controller deeply embedded in the system motherboard FPGA to multiplex the two to three (!) display controller instances out to the single SiI9022 bridge. Set up an extra file with the logic to probe to the FPGA mux register on the system controller bus, then parse the device tree to see if there is a CLCD or HDLCD instance on the core tile (also known as the daughterboard) by looking in the root of the device tree for compatible nodes. - If there is a HDLCD on the core tile, and there is a driver for it, we exit probe and deactivate the motherboard CLCD. We do not touch the DVI mux in this case, to make sure we don't break HDLCD. - If there is a CLCD on both the motherboard and the core tile (only the CA9 has this) the core tile CLCD takes precedence and get muxed to the DVI connector. - Only if there is no working graphics on the core tile, the motherboard CLCD is probed and muxed to the DVI connector. Core tile graphics should always take precedence as it can address all memory and is also faster, however the motherboard CLCD is good to have around for diagnostics and testing. It is possible to test the motherboard CLCD by setting the status = "disabled" property on the core tile CLCD or HDLCD. Scale down the Versatile Express to 16BPP so we can support a 1024x768 display despite the bus bandwidth restrictions on this platform. (The motherboard CLCD supports slightly lower resolution.) Cc: Liviu Dudau <liviu.dudau@arm.com> Cc: Pawel Moll <pawel.moll@arm.com> Acked-by: Eric Anholt <eric@anholt.net> Tested-by: Robin Murphy <robin.murphy@arm.com> Signed-off-by: Linus Walleij <linus.walleij@linaro.org> Link: https://patchwork.freedesktop.org/patch/msgid/20180502134719.8388-1-linus.walleij@linaro.org
2017-11-15Merge tag 'drm-for-v4.15' of git://people.freedesktop.org/~airlied/linuxLinus Torvalds
Pull drm updates from Dave Airlie: "This is the main drm pull request for v4.15. Core: - Atomic object lifetime fixes - Atomic iterator improvements - Sparse/smatch fixes - Legacy kms ioctls to be interruptible - EDID override improvements - fb/gem helper cleanups - Simple outreachy patches - Documentation improvements - Fix dma-buf rcu races - DRM mode object leasing for improving VR use cases. - vgaarb improvements for non-x86 platforms. New driver: - tve200: Faraday Technology TVE200 block. This "TV Encoder" encodes a ITU-T BT.656 stream and can be found in the StorLink SL3516 (later Cortina Systems CS3516) as well as the Grain Media GM8180. New bridges: - SiI9234 support New panels: - S6E63J0X03, OTM8009A, Seiko 43WVF1G, 7" rpi touch panel, Toshiba LT089AC19000, Innolux AT043TN24 i915: - Remove Coffeelake from alpha support - Cannonlake workarounds - Infoframe refactoring for DisplayPort - VBT updates - DisplayPort vswing/emph/buffer translation refactoring - CCS fixes - Restore GPU clock boost on missed vblanks - Scatter list updates for userptr allocations - Gen9+ transition watermarks - Display IPC (Isochronous Priority Control) - Private PAT management - GVT: improved error handling and pci config sanitizing - Execlist refactoring - Transparent Huge Page support - User defined priorities support - HuC/GuC firmware refactoring - DP MST fixes - eDP power sequencing fixes - Use RCU instead of stop_machine - PSR state tracking support - Eviction fixes - BDW DP aux channel timeout fixes - LSPCON fixes - Cannonlake PLL fixes amdgpu: - Per VM BO support - Powerplay cleanups - CI powerplay support - PASID mgr for kfd - SR-IOV fixes - initial GPU reset for vega10 - Prime mmap support - TTM updates - Clock query interface for Raven - Fence to handle ioctl - UVD encode ring support on Polaris - Transparent huge page DMA support - Compute LRU pipe tweaks - BO flag to allow buffers to opt out of implicit sync - CTX priority setting API - VRAM lost infrastructure plumbing qxl: - fix flicker since atomic rework amdkfd: - Further improvements from internal AMD tree - Usermode events - Drop radeon support nouveau: - Pascal temperature sensor support - Improved BAR2 handling - MMU rework to support Pascal MMU exynos: - Improved HDMI/mixer support - HDMI audio interface support tegra: - Prep work for tegra186 - Cleanup/fixes msm: - Preemption support for a5xx - Display fixes for 8x96 (snapdragon 820) - Async cursor plane fixes - FW loading rework - GPU debugging improvements vc4: - Prep for DSI panels - fix T-format tiling scanout - New madvise ioctl Rockchip: - LVDS support omapdrm: - omap4 HDMI CEC support etnaviv: - GPU performance counters groundwork sun4i: - refactor driver load + TCON backend - HDMI improvements - A31 support - Misc fixes udl: - Probe/EDID read fixes. tilcdc: - Misc fixes. pl111: - Support more variants adv7511: - Improve EDID handling. - HDMI CEC support sii8620: - Add remote control support" * tag 'drm-for-v4.15' of git://people.freedesktop.org/~airlied/linux: (1480 commits) drm/rockchip: analogix_dp: Use mutex rather than spinlock drm/mode_object: fix documentation for object lookups. drm/i915: Reorder context-close to avoid calling i915_vma_close() under RCU drm/i915: Move init_clock_gating() back to where it was drm/i915: Prune the reservation shared fence array drm/i915: Idle the GPU before shinking everything drm/i915: Lock llist_del_first() vs llist_del_all() drm/i915: Calculate ironlake intermediate watermarks correctly, v2. drm/i915: Disable lazy PPGTT page table optimization for vGPU drm/i915/execlists: Remove the priority "optimisation" drm/i915: Filter out spurious execlists context-switch interrupts drm/amdgpu: use irq-safe lock for kiq->ring_lock drm/amdgpu: bypass lru touch for KIQ ring submission drm/amdgpu: Potential uninitialized variable in amdgpu_vm_update_directories() drm/amdgpu: potential uninitialized variable in amdgpu_vce_ring_parse_cs() drm/amd/powerplay: initialize a variable before using it drm/amd/powerplay: suppress KASAN out of bounds warning in vega10_populate_all_memory_levels drm/amd/amdgpu: fix evicted VRAM bo adjudgement condition drm/vblank: Tune drm_crtc_accurate_vblank_count() WARN down to a debug drm/rockchip: add CONFIG_OF dependency for lvds ...
2017-11-02License cleanup: add SPDX GPL-2.0 license identifier to files with no licenseGreg Kroah-Hartman
Many source files in the tree are missing licensing information, which makes it harder for compliance tools to determine the correct license. By default all files without license information are under the default license of the kernel, which is GPL version 2. Update the files which contain no license information with the 'GPL-2.0' SPDX license identifier. The SPDX identifier is a legally binding shorthand, which can be used instead of the full boiler plate text. This patch is based on work done by Thomas Gleixner and Kate Stewart and Philippe Ombredanne. How this work was done: Patches were generated and checked against linux-4.14-rc6 for a subset of the use cases: - file had no licensing information it it. - file was a */uapi/* one with no licensing information in it, - file was a */uapi/* one with existing licensing information, Further patches will be generated in subsequent months to fix up cases where non-standard license headers were used, and references to license had to be inferred by heuristics based on keywords. The analysis to determine which SPDX License Identifier to be applied to a file was done in a spreadsheet of side by side results from of the output of two independent scanners (ScanCode & Windriver) producing SPDX tag:value files created by Philippe Ombredanne. Philippe prepared the base worksheet, and did an initial spot review of a few 1000 files. The 4.13 kernel was the starting point of the analysis with 60,537 files assessed. Kate Stewart did a file by file comparison of the scanner results in the spreadsheet to determine which SPDX license identifier(s) to be applied to the file. She confirmed any determination that was not immediately clear with lawyers working with the Linux Foundation. Criteria used to select files for SPDX license identifier tagging was: - Files considered eligible had to be source code files. - Make and config files were included as candidates if they contained >5 lines of source - File already had some variant of a license header in it (even if <5 lines). All documentation files were explicitly excluded. The following heuristics were used to determine which SPDX license identifiers to apply. - when both scanners couldn't find any license traces, file was considered to have no license information in it, and the top level COPYING file license applied. For non */uapi/* files that summary was: SPDX license identifier # files ---------------------------------------------------|------- GPL-2.0 11139 and resulted in the first patch in this series. If that file was a */uapi/* path one, it was "GPL-2.0 WITH Linux-syscall-note" otherwise it was "GPL-2.0". Results of that was: SPDX license identifier # files ---------------------------------------------------|------- GPL-2.0 WITH Linux-syscall-note 930 and resulted in the second patch in this series. - if a file had some form of licensing information in it, and was one of the */uapi/* ones, it was denoted with the Linux-syscall-note if any GPL family license was found in the file or had no licensing in it (per prior point). Results summary: SPDX license identifier # files ---------------------------------------------------|------ GPL-2.0 WITH Linux-syscall-note 270 GPL-2.0+ WITH Linux-syscall-note 169 ((GPL-2.0 WITH Linux-syscall-note) OR BSD-2-Clause) 21 ((GPL-2.0 WITH Linux-syscall-note) OR BSD-3-Clause) 17 LGPL-2.1+ WITH Linux-syscall-note 15 GPL-1.0+ WITH Linux-syscall-note 14 ((GPL-2.0+ WITH Linux-syscall-note) OR BSD-3-Clause) 5 LGPL-2.0+ WITH Linux-syscall-note 4 LGPL-2.1 WITH Linux-syscall-note 3 ((GPL-2.0 WITH Linux-syscall-note) OR MIT) 3 ((GPL-2.0 WITH Linux-syscall-note) AND MIT) 1 and that resulted in the third patch in this series. - when the two scanners agreed on the detected license(s), that became the concluded license(s). - when there was disagreement between the two scanners (one detected a license but the other didn't, or they both detected different licenses) a manual inspection of the file occurred. - In most cases a manual inspection of the information in the file resulted in a clear resolution of the license that should apply (and which scanner probably needed to revisit its heuristics). - When it was not immediately clear, the license identifier was confirmed with lawyers working with the Linux Foundation. - If there was any question as to the appropriate license identifier, the file was flagged for further research and to be revisited later in time. In total, over 70 hours of logged manual review was done on the spreadsheet to determine the SPDX license identifiers to apply to the source files by Kate, Philippe, Thomas and, in some cases, confirmation by lawyers working with the Linux Foundation. Kate also obtained a third independent scan of the 4.13 code base from FOSSology, and compared selected files where the other two scanners disagreed against that SPDX file, to see if there was new insights. The Windriver scanner is based on an older version of FOSSology in part, so they are related. Thomas did random spot checks in about 500 files from the spreadsheets for the uapi headers and agreed with SPDX license identifier in the files he inspected. For the non-uapi files Thomas did random spot checks in about 15000 files. In initial set of patches against 4.14-rc6, 3 files were found to have copy/paste license identifier errors, and have been fixed to reflect the correct identifier. Additionally Philippe spent 10 hours this week doing a detailed manual inspection and review of the 12,461 patched files from the initial patch version early this week with: - a full scancode scan run, collecting the matched texts, detected license ids and scores - reviewing anything where there was a license detected (about 500+ files) to ensure that the applied SPDX license was correct - reviewing anything where there was no detection but the patch license was not GPL-2.0 WITH Linux-syscall-note to ensure that the applied SPDX license was correct This produced a worksheet with 20 files needing minor correction. This worksheet was then exported into 3 different .csv files for the different types of files to be modified. These .csv files were then reviewed by Greg. Thomas wrote a script to parse the csv files and add the proper SPDX tag to the file, in the format that the file expected. This script was further refined by Greg based on the output to detect more types of files automatically and to distinguish between header and source .c files (which need different comment types.) Finally Greg ran the script using the .csv files to generate the patches. Reviewed-by: Kate Stewart <kstewart@linuxfoundation.org> Reviewed-by: Philippe Ombredanne <pombredanne@nexb.com> Reviewed-by: Thomas Gleixner <tglx@linutronix.de> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2017-09-10drm/pl111: Add handling of Versatile platformsLinus Walleij
The ARM reference designs in the Versatile family: Integrator, Versatile and RealView can make use of the new DRM driver as well. We just need to create a bit of platform-specific code for them that we isolate to its own file. Reviewed-by: Eric Anholt <eric@anholt.net> Signed-off-by: Linus Walleij <linus.walleij@linaro.org> Link: https://patchwork.freedesktop.org/patch/msgid/20170908124709.4758-7-linus.walleij@linaro.org
2017-09-10drm/pl111: Replace custom connector with panel bridgeLinus Walleij
This replaces the custom connector in the PL111 with the panel bridge helper. This works nicely for all standard panels, but since there are several PL11x-based systems that will need to use the dumb VGA connector bridge we use drm_of_find_panel_or_bridge() and make some headroom for dealing with bridges that are not panels as well, and drop a TODO in the code. Reviewed-by: Eric Anholt <eric@anholt.net> Signed-off-by: Linus Walleij <linus.walleij@linaro.org> Link: https://patchwork.freedesktop.org/patch/msgid/20170908124709.4758-3-linus.walleij@linaro.org
2017-05-19drm/pl111: Add a debugfs node to dump our registers.Eric Anholt
While debugging an X11 display failure, I wanted to see where we were actually scanning out from. This is probably generally useful to others that might be working on this device. v2: Fix uint32_t sparse warning. Signed-off-by: Eric Anholt <eric@anholt.net> Link: http://patchwork.freedesktop.org/patch/msgid/20170518005640.10310-1-eric@anholt.net Reviewed-by: Linus Walleij <linus.walleij@linaro.org> (v1)
2017-05-08drm/pl111: Initial drm/kms driver for pl111Tom Cooksey
This is a modesetting driver for the pl111 CLCD display controller found on various ARM platforms such as the Versatile Express. The driver has only been tested on the bcm911360_entphn platform so far, with PRIME-based buffer sharing between vc4 and clcd. It reuses the existing devicetree binding, while not using quite as many of its properties as the fbdev driver does (those are left for future work). v2: Nearly complete rewrite by anholt, cutting 2/3 of the code thanks to DRM core's excellent new helpers. v3: Don't match pl110 any more, don't attach if we don't have a DRM panel, use DRM_GEM_CMA_FOPS, update MAINTAINERS, use the simple display helper, use drm_gem_cma_dumb_create (same as our wrapper). v4: Change the driver's .name to not clash with fbdev in sysfs, drop platform alias, drop redundant "drm" in DRM driver name, hook up .prepare_fb to the CMA helper so that DMA fences should work. v5: Move register definitions inside the driver directory, fix build in COMPILE_TEST and !AMBA mode. v6: Drop TIM2_CLKSEL for now to be consistent with existing DT bindings, switch back to external register definitions. Signed-off-by: Tom Cooksey <tom.cooksey@arm.com> Signed-off-by: Eric Anholt <eric@anholt.net> Reviewed-by: Linus Walleij <linus.walleij@linaro.org> (v5) Acked-by: Daniel Vetter <daniel.vetter@ffwll.ch> Link: http://patchwork.freedesktop.org/patch/msgid/20170413031746.12921-2-eric@anholt.net